Effect of the scanner type on the marginal gap and internal fit of two monolithic CAD/CAM esthetic crown materials: An in vitro study

被引:0
|
作者
Farag, Engy Adel Ahmed
Rizk, Amr [1 ]
Ashraf, Reem [2 ,3 ]
Eldin, Farid Emad [1 ]
机构
[1] British Univ Egypt BUE, Fac Dent, Dept Fixed Prosthodont, Cairo, Egypt
[2] King Salman Int Univ KSIU, Fac Dent, Dept Prosthet Dent, Div Fixed Prosthodont, El Tor, Egypt
[3] King Salman Int Univ, Fac Dent, Dept Prosthet Dent, Div Dent Biomat, El Tor, Egypt
关键词
marginal gap; internal fit; monolithic crowns; digital scanning; DIGITAL IMPRESSIONS; ACCURACY; ADAPTATION;
D O I
10.17219/dmp/185895
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background. The durability of indirect restorations is significantly influenced by marginal adaptation and internal fit. The use of computer-aided design/computer-aided manufacturing (CAD/CAM) with digital impressions has reduced dental prosthesis fabrication errors, improving the long-term survivability of the restorations.<br /> Objectives. The present study assessed the impact of intraoral and extraoral scanning methods on the marginal adaptation and internal fit of 2 different types of monolithic crowns manufactured using CAD/CAM. Material and methods. A total of 40 three-dimensional (3D) resin-printed dies were randomly assigned to 2 groups based on the type of crown material ( n = 20 per group). Each group was divided into 2 subgroups ( n = 10 per group) according to the die-scanning technique: subgroup A, scanned using the intraoral scanner (IOS) Primescan; and subgroup B, scanned using the extraoral scanner (EOS) inEos X5. The digitized photos were converted into a 3D virtual crown design using CAD software. The internal discrepancy values, and the marginal gap between the 3D resin-printed die and the crown were assessed using a x 50 digital microscope. The data was checked for normality with the Kolmogorov-Smirnov test, and the Mann-Whitney U test was used to compare the tested groups. The collected data was analyzed at a significance level set at p < 0.05. Results. The different scanning techniques used had a statistically significant effect on the vertical marginal gap and the internal fit [<mu>m] ( p < 0.05). As far as the crown materials are concerned, BRILLIANT Crios showed a significantly higher marginal gap as compared to Tetric CAD when scanned with inEos X5 ( p = 0.004), whereas the differences were insignificant with regard to the internal fit ( p > 0.05).The crown parameters tested with both scanning systems were within the clinically acceptable ranges. Conclusions. Scanning methods and crown materials had an impact on the internal fit and vertical marginal gap of monolithic crowns.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Marginal and Internal Fit of Monolithic Zirconia Crowns Fabricated by Using Two Different CAD-CAM Workflows: An In Vitro Study
    Cin, Vahap
    Izgi, Ayca Deniz
    Kale, Ediz
    Yilmaz, Burak
    [J]. PROSTHESIS, 2023, 5 (01): : 35 - 47
  • [2] In vitro study on marginal and internal fit of CAD/CAM all-ceramic crowns
    Nakamura, T
    Tanaka, H
    Kinuta, S
    Akao, T
    Okamoto, K
    Wakabayashi, K
    Yatani, H
    [J]. DENTAL MATERIALS JOURNAL, 2005, 24 (03) : 456 - 459
  • [3] Evaluation of Marginal/Internal Fit and Fracture Load of Monolithic Zirconia and Zirconia Lithium Silicate (ZLS) CAD/CAM Crown Systems
    Sadeqi, Haneen A.
    Baig, Mirza Rustum
    Al-Shammari, Mohammad
    [J]. MATERIALS, 2021, 14 (21)
  • [4] Effect of different CAD-CAM materials on the marginal and internal adaptation of endocrown restorations: An in vitro study
    El Ghoul, Wiam A.
    Ozcan, Mutlu
    Ounsi, Hani
    Tohme, Hani
    Salameh, Ziad
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 128 - 134
  • [5] Effect of different intraoral scanning strategies on the marginal and internal fit of CAD-CAM inlay restorations: An in vitro study
    Salem, Mohamed M.
    Elmahy, Waleed A.
    Nasr, Dina M.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (03):
  • [6] Effect of high-speed sintering on the marginal and internal fit of CAD/CAM-fabricated monolithic zirconia crowns
    Seulgi Lee
    Gyujin Choi
    Jinhyeok Choi
    Youngjun Kim
    Hee-Kyung Kim
    [J]. Scientific Reports, 13 (1)
  • [7] Effect of high-speed sintering on the marginal and internal fit of CAD/CAM-fabricated monolithic zirconia crowns
    Lee, Seulgi
    Choi, Gyujin
    Choi, Jinhyeok
    Kim, Youngjun
    Kim, Hee-Kyung
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01):
  • [8] Effect of Chairside CAD/CAM Restoration Type on Marginal Fit Accuracy: A Comparison of Crown, Inlay and Onlay Restorations
    Merrill, Tyson C.
    Mackey, Thomas
    Luc, Raymond
    Lung, Dominique
    Naseem, Aneela
    Abduo, Jaafar
    [J]. EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2021, 29 (02): : 119 - 127
  • [9] Comparison of marginal fit of Lava CAD/CAM crown-copings with two finish lines
    Re, Dino
    Cerutti, Francesca
    Augusti, Gabriele
    Cerutti, Antonio
    Augusti, Davide
    [J]. INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY, 2014, 9 (03): : 426 - 435
  • [10] Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings
    Beuer, Florian
    Aggstaller, Hans
    Richter, Juliane
    Edelhoff, Daniel
    Gernet, Wolfgang