Five- year migration of uncemented femoral components in total knee arthroplasty with either highly cross- linked or conventional polyethylene inserts: a blinded randomized controlled trial using radiostereometric analysis

被引:0
|
作者
de Ridder, R. [1 ,2 ,3 ,4 ]
Kaptein, B. L. [1 ,4 ]
Pijls, B. G. [1 ,4 ]
Nelissen, R. G. H. H. [1 ,4 ]
Kaptijn, H. H. [1 ,2 ,3 ]
机构
[1] Lange Land Hosp, Zoetermeer, Netherlands
[2] Lange Land Hosp Zoetermeer, Dept Orthopaed, Zoetermeer, Netherlands
[3] Reinier Haga Orthopaed Ctr, Zoetermeer, Netherlands
[4] Leiden Univ, Med Ctr, Dept Orthopaed, Leiden, Netherlands
来源
BONE & JOINT JOURNAL | 2024年 / 106B卷 / 08期
关键词
ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS; WEAR; PROSTHESIS; FIXATION;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross- linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate- retaining total knee arthroplasty (TKA). Secondary aims included clinical outcomes and patient- reported outcome measures (PROMs). We have previously reported the migration and outcome of the tibial components in these patients. Methods A double- blinded randomized controlled trial was conducted including 96 TKAs. The migration of the femoral component was measured with radiostereometry (RSA) at three and six months and one, two, and five years postoperatively. PROMs were collected preoperatively and at all periods of follow- up. Results There was no clinically relevant difference in terms of migration of the femoral component or PROMs between the HXLPE and PE groups. The mean difference in migration (maximum total point motion), five years postopeatively, was 0.04 mm (95% CI-0.06 to 0.16) in favour of the PE group. Conclusion There was no clinically relevant difference in migration of the femoral component, for up to five years between the two groups. These findings will help to establish a benchmark for future studies on migration of femoral components in TKA.
引用
收藏
页码:826 / 833
页数:8
相关论文
共 27 条
  • [1] Five-year migration and insert wear of uncemented tibial components with either conventional polyethylene or sequentially annealed highly crosslinked polyethylene inserts: a blinded randomized controlled trial using radiostereometric analysis
    de Ridder, R.
    Kaptein, B. L.
    Pijls, B. G.
    Nelissen, R. G. H. H.
    Kaptijn, H. H.
    BONE & JOINT JOURNAL, 2023, 105B (05): : 518 - 525
  • [2] Highly cross-linked versus conventional polyethylene inserts in total hip arthroplasty, a five-year Roentgen stereophotogrammetric analysis randomised controlled trial
    van Loon, Justin
    Hoornenborg, Daniel
    Sierevelt, Inger
    Opdam, Kim T. M.
    Kerkhoffs, Gino M. M. J.
    Haverkamp, Daniel
    WORLD JOURNAL OF ORTHOPEDICS, 2020, 11 (10): : 442 - 452
  • [3] The Seven-Year Wear of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty A Double-Blind, Randomized Controlled Trial Using Radiostereometric Analysis
    Thomas, Geraint E. R.
    Simpson, David J.
    Mehmood, Shahid
    Taylor, Adrian
    McLardy-Smith, Peter
    Gill, Harinderjit Singh
    Murray, David W.
    Glyn-Jones, Sion
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (08): : 716 - 722
  • [4] The Otto Aufranc Award -: Highly cross-linked polyethylene in Total Hip Arthroplasty -: Randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis
    Digas, G
    Kärrholm, J
    Thanner, J
    Malchau, H
    Herberts, P
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) : 6 - 16
  • [5] 5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets -: Two randomized studies using radiostereometric analysis
    Digas, Georgios
    Karrholm, Johan
    Thanner, Jonas
    Herberts, Peter
    ACTA ORTHOPAEDICA, 2007, 78 (06) : 746 - 754
  • [6] The creep and wear of highly cross-linked polyethylene - A three-year randomised, controlled trial using radiostereometric analysis
    Glyn-Jones, S.
    McLardy-Smith, P.
    Gill, H. S.
    Murray, D. W.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (05): : 556 - 561
  • [7] Five-Year Comparison of Oxidized Zirconium and Cobalt-Chromium Femoral Components in Total Knee Arthroplasty A Randomized Controlled Trial
    Hui, Catherine
    Salmon, Lucy
    Maeno, Shinichi
    Roe, Justin
    Walsh, William
    Pinczewski, Leo
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (07): : 624 - 630
  • [8] Highly Cross-Linked Polyethylene Reduces Wear and Revision Rates in Total Hip Arthroplasty A 10-Year Double-Blinded Randomized Controlled Trial
    Devane, Peter A.
    Horne, James Geoffrey
    Ashmore, Alexander
    Mutimer, Jonathon
    Kim, Woosung
    Stanley, James
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (20): : 1703 - 1714
  • [9] Five-Year Experience of Vitamin E-Diffused Highly Cross-Linked Polyethylene Wear in Total Hip Arthroplasty Assessed by Radiostereometric Analysis
    Nebergall, Audrey K.
    Troelsen, Anders
    Rubash, Harry E.
    Malchau, Henrik
    Rolfson, Ola
    Greene, Meridith E.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (06): : 1251 - 1255
  • [10] Uncemented tantalum metal components versus cemented tibial components in total knee arthroplasty: 11-to 15-year outcomes of a single-blinded randomized controlled trial
    Hampton, M.
    Nlansoor, J.
    Getty, J.
    Sutton, P. M.
    BONE & JOINT JOURNAL, 2020, 102B (08): : 1025 - 1032