Longevity of a Brain-Computer Interface for Amyotrophic Lateral Sclerosis

被引:1
|
作者
Vansteensel, Mariska J. [1 ]
Leinders, Sacha [1 ]
Branco, Mariana P. [1 ]
Crone, Nathan E. [2 ]
Denison, Timothy [3 ,4 ]
Freudenburg, Zachary V. [1 ]
Geukes, Simon H. [1 ]
Gosselaar, Peter H. [1 ]
Raemaekers, Mathijs [1 ]
Schippers, Anouck [1 ]
Verberne, Malinda [1 ]
Aarnoutse, Erik J. [1 ]
Ramsey, Nick F. [1 ]
机构
[1] Univ Med Ctr Utrecht, Brain Ctr, Dept Neurol & Neurosurg, POB 85060, NL-3508 AB Utrecht, Netherlands
[2] Johns Hopkins Univ, Sch Med, Dept Neurol, Baltimore, MD USA
[3] Univ Oxford, Inst Biomed Engn, Oxford, England
[4] Univ Oxford, Dept Engn Sci, Oxford, England
来源
NEW ENGLAND JOURNAL OF MEDICINE | 2024年 / 391卷 / 07期
基金
荷兰研究理事会;
关键词
D O I
10.1056/NEJMoa2314598
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The durability of communication with the use of brain-computer interfaces in persons with progressive neurodegenerative disease has not been extensively examined. We report on 7 years of independent at-home use of an implanted brain-computer interface for communication by a person with advanced amyotrophic lateral sclerosis (ALS), the inception of which was reported in 2016. The frequency of at-home use increased over time to compensate for gradual loss of control of an eye-gaze-tracking device, followed by a progressive decrease in use starting 6 years after implantation. At-home use ended when control of the brain-computer interface became unreliable. No signs of technical malfunction were found. Instead, the amplitude of neural signals declined, and computed tomographic imaging revealed progressive atrophy, which suggested that ALS-related neurodegeneration ultimately rendered the brain-computer interface ineffective after years of successful use, although alternative explanations are plausible. (Funded by the National Institute on Deafness and Other Communication Disorders and others; ClinicalTrials.gov number, NCT02224469.) In a person with amyotrophic lateral sclerosis, an implanted brain-computer interface for assisted communication was effective for more than 7 years. ALS-related neurodegeneration ultimately rendered the device ineffective.
引用
下载
收藏
页码:619 / 626
页数:8
相关论文
共 50 条
  • [1] A cognitive brain-computer interface for patients with amyotrophic lateral sclerosis
    Hohmann, M. R.
    Fomina, T.
    Jayaram, V.
    Widmann, N.
    Foerster, C.
    Just, J.
    Synofzik, M.
    Schoelkopf, B.
    Schoels, L.
    Grosse-Wentrup, M.
    BRAIN-COMPUTER INTERFACES: LAB EXPERIMENTS TO REAL-WORLD APPLICATIONS, 2016, 228 : 221 - 239
  • [2] A Cognitive Brain-Computer Interface for Patients with Amyotrophic Lateral Sclerosis
    Hohmann, Matthias R.
    Fomina, Tatiana
    Jayaram, Vinay
    Widmann, Natalie
    Foerster, Christian
    vom Hagen, Jennifer Mueller
    Synofzik, Matthis
    Schoelkopf, Bernhard
    Schoels, Ludger
    Grosse-Wentrup, Moritz
    2015 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC 2015): BIG DATA ANALYTICS FOR HUMAN-CENTRIC SYSTEMS, 2015, : 3187 - 3191
  • [3] Amyotrophic lateral sclerosis progression and stability of brain-computer interface communication
    Silvoni, Stefano
    Cavinato, Marianna
    Volpato, Chiara
    Ruf, Carolin A.
    Birbaumer, Niels
    Piccione, Francesco
    AMYOTROPHIC LATERAL SCLEROSIS AND FRONTOTEMPORAL DEGENERATION, 2013, 14 (5-6) : 390 - 396
  • [4] Brain-computer interfaces for amyotrophic lateral sclerosis
    McFarland, Dennis J.
    MUSCLE & NERVE, 2020, 61 (06) : 702 - 707
  • [5] Adaptive Brain-Computer Interface with Attention Alterations in Patients with Amyotrophic Lateral Sclerosis
    Aliakbaryhosseinabadi, S.
    Mrachacz-Kersting, N.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 3188 - 3191
  • [6] A visual brain-computer interface as communication aid for patients with amyotrophic lateral sclerosis
    Verbaarschot, Ceci
    Lutu, Andreea
    Borhanazad, Marzieh
    Thielen, Jordy
    Broek, Philip van den
    Farquhar, Jason
    Weikamp, Janneke
    Raaphorst, Joost
    Groothuis, Jan T.
    Desain, Peter
    Tump, Danielle
    CLINICAL NEUROPHYSIOLOGY, 2021, 132 (10) : 2404 - 2415
  • [7] Independent home use of a brain-computer interface by people with amyotrophic lateral sclerosis
    Wolpaw, Jonathan R.
    Bedlack, Richard S.
    Reda, Domenic J.
    Ringer, Robert J.
    Banks, Patricia G.
    Vaughan, Theresa M.
    Heckman, Susan M.
    McCane, Lynn M.
    Carmack, Charles S.
    Winden, Stefan
    McFarland, Dennis J.
    Sellers, Eric W.
    Shi, Hairong
    Paine, Tamara
    Higgins, Donald S.
    Lo, Albert C.
    Patwa, Huned S.
    Hill, Katherine J.
    Huang, Grant D.
    Ruff, Robert L.
    NEUROLOGY, 2018, 91 (03) : E258 - E267
  • [8] Brain-computer interfaces in amyotrophic lateral sclerosis: A metanalysis
    Marchetti, Mauro
    Priftis, Konstantinos
    CLINICAL NEUROPHYSIOLOGY, 2015, 126 (06) : 1255 - 1263
  • [9] Acceptance of brain-computer interfaces in amyotrophic lateral sclerosis
    Geronimo, Andrew
    Stephens, Helen E.
    Schiff, Steven J.
    Simmons, Zachary
    AMYOTROPHIC LATERAL SCLEROSIS AND FRONTOTEMPORAL DEGENERATION, 2015, 16 (3-4) : 258 - 264
  • [10] A P300-based brain-computer interface for people with amyotrophic lateral sclerosis
    Nijboer, F.
    Sellers, E. W.
    Mellinger, J.
    Jordan, M. A.
    Matuz, T.
    Furdea, A.
    Halder, S.
    Mochty, U.
    Krusienski, D. J.
    Vaughan, T. M.
    Wolpaw, J. R.
    Birbaumer, N.
    Kuebler, A.
    CLINICAL NEUROPHYSIOLOGY, 2008, 119 (08) : 1909 - 1916