Diffusion-weighted Echo Planar Imaging with Compressed SENSE (EPICS-DWI) for Pancreas Assessment: A Multicenter Study

被引:0
|
作者
Kaga, Tetsuro [1 ]
Noda, Yoshifumi [1 ,2 ]
Asano, Masashi [1 ]
Kawai, Nobuyuki [1 ]
Kajita, Kimihiro [3 ]
Takai, Yukiko [1 ]
Ejima, Fumitaka [4 ]
Hyodo, Fuminori [5 ,6 ]
Kato, Hiroki [1 ]
Fukukura, Yoshihiko [7 ]
Matsuo, Masayuki [1 ,8 ]
机构
[1] Gifu Univ, Dept Radiol, 1-1 Yanagido, Gifu, Gifu 5011194, Japan
[2] Gifu Univ, Dept Frontier Sci Imaging, Gifu, Gifu, Japan
[3] Gifu Univ Hosp, Dept Radiol Serv, Gifu, Gifu, Japan
[4] Kagoshima Univ, Dept Radiol, Grad Sch Med & Dent Sci, Kagoshima, Kagoshima, Japan
[5] Gifu Univ, Inst Adv Study, Ctr One Med Innovat Translat Res COMIT, Gifu, Gifu, Japan
[6] Gifu Univ, Grad Sch Med, Dept Pharmacol, Gifu, Gifu, Japan
[7] Kawasaki Med Sch, Dept Radiol, Kurashiki, Okayama, Japan
[8] Gifu Univ, Innovat Res Ctr Quantum Med, Sch Med, Gifu, Gifu, Japan
关键词
abdomen; diffusion-weighted imaging; magnetic resonance imaging; pancreas; pancreatic ductal adenocarcinoma; ADENOCARCINOMA; CANCER;
D O I
10.2463/mrms.mp.2024-0046
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aimed to evaluate the feasibility of single-shot echo planar diffusion-weighted imaging with compressed SENSE (EPICS-DWI) for pancreas assessment by comparing with single-shot echo planar DWI with parallel imaging (PI-DWI). Methods: This multicenter prospective study included 27 consecutive participants with untreated pancreatic ductal adenocarcinoma (PDAC) (15 men; mean age, 67 +/- 10 years) who underwent pancreatic protocol MRI including both PI-DWI and EPICS-DWI. Two radiologists independently and randomly reviewed the high b-value DWI images and qualitatively assigned confidence scores for overall image quality, image noise, pancreas conspicuity, and PDAC conspicuity using a 5-point scale. One radiologist measured the PDAC-to-pancreas contrast-to-noise-ratio (CNR) on high b-value DWI images and the apparent diffusion coefficient (ADC) value of PDAC. Qualitative and quantitative parameters were compared between PI-DWI and EPICS-DWI using the Wilcoxon signed-rank test. Results: The confidence scores for overall image quality (P < 0.001 in both radiologists) and image noise (P < 0.001 in both radiologists) were higher in EPICS-DWI than in PI-DWI. The pancreas conspicuity was better in EPICS-DWI than in PI-DWI in one of the radiologists (P = 0.02 and 0.06). The PDAC conspicuity was comparable between PI-DWI and EPICS-DWI (P > 0.99 in both radiologists). The PDAC-to-pancreas CNR was higher in EPICS-DWI than in PI-DWI (P = 0.02), while the ADC value of PDAC in PI-DWI was not significantly different compared to that in EPICS-DWI (P = 0.48). Conclusion: The image quality and PDAC-to-pancreas CNR was improved in EPICS-DWI compared to PI-DWI. However, the conspicuity and ADC value of PDAC were comparable between PI-DWI and EPICS-DWI.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Diagnostic ability of diffusion-weighted imaging using echo planar imaging with compressed SENSE (EPICS) for differentiating hepatic hemangioma and liver metastasis
    Kaga, Tetsuro
    Noda, Yoshifumi
    Asano, Masashi
    Kawai, Nobuyuki
    Kajita, Kimihiro
    Hyodo, Fuminori
    Kato, Hiroki
    Matsuo, Masayuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 167
  • [2] Echo planar imaging with compressed sensitivity encoding (EPICS): Usefulness for head and neck diffusion-weighted MRI
    Yoshida, Naofumi
    Nakaura, Takeshi
    Morita, Kosuke
    Yoneyama, Masami
    Tanoue, Shota
    Yokota, Yasuhiro
    Uetani, Hiroyuki
    Nagayama, Yasunori
    Kidoh, Masafumi
    Azuma, Minako
    Hirai, Toshinori
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 155
  • [3] Accelerated diffusion-weighted imaging of the prostate employing echo planar imaging with compressed SENSE based reconstruction
    Layer, Yannik Christian
    Muertz, Petra
    Isaak, Alexander
    Bischoff, Leon
    Wichtmann, Barbara Daria
    Katemann, Christoph
    Weiss, Kilian
    Luetkens, Julian
    Pieper, Claus Christian
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [4] Neuroimaging of venous stroke: Echo planar diffusion-weighted imaging (DWI) in 13 cases
    Mullins, ME
    Grant, EP
    Wang, B
    Gonzalez, RG
    Schaefer, PW
    RADIOLOGY, 2000, 217 : 339 - 339
  • [5] Diffusion-weighted imaging of the abdomen using echo planar imaging with compressed SENSE: Feasibility, image quality, and ADC value evaluation
    Kaga, Tetsuro
    Noda, Yoshifumi
    Mori, Takayuki
    Kawai, Nobuyuki
    Takano, Hirota
    Kajita, Kimihiro
    Yoneyama, Masami
    Akamine, Yuta
    Kato, Hiroki
    Hyodo, Fuminori
    Matsuo, Masayuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 142
  • [6] Reproducibility of quantitative ADC, T1, and T2 measurement on the cerebral cortex: Utility of whole brain echo-planar DWI with compressed SENSE (EPICS-DWI): A pilot study
    Yamashita, Koji
    Yoneyama, Masami
    Kikuchi, Kazufumi
    Wada, Tatsuhiro
    Murazaki, Hiroo
    Watanuki, Hiroaki
    Mikayama, Ryoji
    Ishigami, Kousei
    Togao, Osamu
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2023, 11
  • [7] Simultaneous multislice echo-planar diffusion-weighted imaging (DWI) in patients with focal liver lesions: a comparative study with conventional DWI
    Wu, Yingyi
    Ye, Zheng
    Yang, Ting
    Yao, Shan
    Chen, Jie
    Yin, Ting
    Tang, Hehan
    Song, Bin
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (09)
  • [8] Utility of Echo-planar Imaging with Compressed Sensitivity Encoding (EPICS) in the Evaluation of Small Breast Cancers Using Diffusion-weighted Imaging with Background Suppression (DWIBS)
    Kazama, Toshiki
    Nagafuji, Yui
    Niikura, Naoki
    Okamura, Takuho
    Van Cauteren, Marc
    Obara, Makoto
    Takano, Susumu
    Konta, Natsuo
    Horie, Tomohiko
    Takahara, Taro
    Kumaki, Nobue
    Niwa, Tetsu
    Hashimoto, Jun
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2024,
  • [9] Ultrafast MR imaging of the abdomen: Echo planar imaging and diffusion-weighted imaging
    Yamashita, Y
    Tang, Y
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (02): : 367 - 374
  • [10] Gradient preemphasis calibration in diffusion-weighted echo-planar imaging
    Papadakis, NG
    Martin, KM
    Pickard, JD
    Hall, LD
    Carpenter, TA
    Huang, CLH
    MAGNETIC RESONANCE IN MEDICINE, 2000, 44 (04) : 616 - 624