A conjugate study on the application of combined impingement and film cooling for a turbine blade tip

被引:1
|
作者
Li, Feng [1 ,2 ]
Liu, Zhao [1 ]
Tao, Yong [1 ]
Zhang, Weixin [1 ]
Feng, Zhenping [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Shaanxi Engn Lab Turbomachinery & Power Equipment, Xian 710049, Peoples R China
[2] China Aerodynam Res & Dev Ctr, Hyperveloc Aerodynam Inst, Mianyang 621000, Peoples R China
关键词
Conjugate heat transfer; Overall cooling effectiveness; Blade tip; Combined impingement and film cooling;
D O I
10.1016/j.applthermaleng.2024.123594
中图分类号
O414.1 [热力学];
学科分类号
摘要
The blade tip region is facing an extremely harsh environment, and it is critical to apply the cooling method here. Conventional film cooling (FC) has been commonly used for tip cooling till now, but it consumes a lot of coolant thereby reducing the gas turbine operating efficiency. It has been verified that the combined impingement and film cooling (CIFC) technique shows better cooling performance than the FC case, but its performance on the tip region is not yet known. Therefore, in this paper, the combined impingement and film cooling technique was implemented for the blade tip region, and was compared with the conventional film cooling using a conjugate method. Then, based on the CIFC technique, overall cooling effectiveness (phi) distributions of the tip were obtained via the Infrared thermography with different impingement hole layouts, blowing ratios ( M = 1.0 - 2.5), and relative impingement distances ( X n = 1.5, 3.0, 6.0). The validated numerical simulations were adopted for additional analysis. The results show that, compared with the conventional FC, the application of the CIFC technique can increase the tip phi (increased by 70 % - 80 %) and decrease the tip solid temperature. Moreover, the low phi values were detected near the leading edge (LE), and placing more impingement holes near the LE will help increase the phi values here. What ' s more, increasing the relative impingement distance would weaken the cooling performance. At a coolant M = 1.0, the phi was decreased by 4.1 % and 12.9 % from X n = 1.5 to X n = 6.0, respectively. The application of the CIFC technique for the tip region can diminish the coolant supply and hence can be a reference in the tip cooling design.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] A Combined Experimental and Numerical Study of the Turbine Blade Tip Film Cooling Effectiveness Under Rotation Condition
    Rezasoltani, Mohsen
    Lu, Kun
    Schobeiri, Meinhard T.
    Han, Je-Chin
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2015, 137 (05):
  • [2] A Comparative Study on Conjugate Heat Transfer of Impingement-Film Composite Cooling and Swirl-Film Composite Cooling on Leading Edge of a Turbine Blade
    Liu, Zhao
    Jia, Zhe
    Zhang, Zhixin
    Feng, Zhenping
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2021, 55 (04): : 116 - 125
  • [3] A Combined Experimental and Numerical Study of the Turbine Blade Tip Film Cooling Effectiveness under Rotation Condition
    Rezasoltani, M.
    Lu, K.
    Schobeiri, M. T.
    Han, J. C.
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2014, VOL 5B, 2014,
  • [4] Conjugate Heat Transfer Predictions on Combined Impingement and Film Cooling of a Blade Leading Edge Model
    Liu, Zhao
    Li, Feng
    Zhang, Zhixin
    Feng, Zhenping
    Simon, Terrence W.
    HEAT TRANSFER ENGINEERING, 2021, 42 (16) : 1363 - 1380
  • [5] Turbine blade platform impingement cooling with effects of film extraction and roughness
    Bunker, Ronald S.
    Bailey, Jeremy C.
    Proceedings of the ASME Turbo Expo 2005, Vol 3 Pts A and B, 2005, : 419 - 429
  • [6] A Comparative Study of Film Cooling with Combined Impingement and Film Cooling
    Panda, R. K.
    Pujari, A. K.
    Gudla, B.
    JOURNAL OF APPLIED FLUID MECHANICS, 2023, 16 (07) : 1386 - 1401
  • [7] Study on Aerodynamic and Cooling Performance of Turbine Blade Squealer Tip with Film Cooling Pulsation Characteristics Considered
    Xu C.
    Li Z.
    Li J.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2022, 56 (05): : 127 - 140
  • [8] Investigation of Film Cooling Effectiveness on Squealer Tip of a Gas Turbine Blade
    Yang, Dianliang
    Feng, Zhenping
    Yu, Xiaobing
    PROCEEDINGS OF THE ASME TURBO EXPO 2009, VOL 3, PTS A AND B, 2009, : 991 - 1000
  • [9] Heat transfer and film cooling effectiveness on the squealer tip of a turbine blade
    Park, Jun Su
    Lee, Dong Hyun
    Rhee, Dong-Ho
    Kang, Shin Hyung
    Cho, Hyung Flee
    ENERGY, 2014, 72 : 331 - 343
  • [10] Film cooling characteristics analysis of turbine blade tip in transonic flow
    Zhang B.
    Xia J.
    Hu Q.
    Zhu H.
    Guofang Keji Daxue Xuebao/Journal of National University of Defense Technology, 2024, 46 (02): : 153 - 161