VALIDITY OF THE EKBLOM-BAK CYCLE ERGOMETER TEST IN PATIENTS WITH CARDIOVASCULAR DISEASE

被引:0
|
作者
Storli, Magnus Fransplass [1 ]
Fimland, Marius Steiro [1 ,2 ]
Engan, Harald Kare [3 ,4 ]
Sandmael, Jon Arne [3 ,4 ]
机构
[1] NTNU Norwegian Univ Sci & Technol, Fac Med & Hlth Sci, Dept Neuromed & Movement Sci, Trondheim, Norway
[2] Unicare Helsefort Rehabil Ctr, Rissa, Norway
[3] Unicare Norway, Oslo, Norway
[4] Unicare Roros, Roros, Norway
关键词
cardiovascular disease; submaximal test; cardio- respiratory fitness; rehabilitation; CARDIORESPIRATORY FITNESS; SCIENTIFIC STATEMENT; EXERCISE; HEART; REHABILITATION; PREDICTION; CARDIOLOGY; COMMITTEE; MEN;
D O I
10.2340/jrm.v56.39901
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To assess the validity of the Ekblom-Bak cycle ergometer test in patients with cardiovascular disease admitted to cardiac rehabilitation. from the Ekblom-Bak test was compared with directly measured peak oxygen consumption from a treadmill cardiopulmonary exercise test. Patients completed the cardiopulmonary exercise test first, followed by the Ekblom-Bak test after 24 h rest. Pearson's correlation coefficient (r) was used to establish the correlation between estimated and measured peak oxygen consumption, and Bland- Altman plots with limits of agreement were used to determine the bias between the 2 tests. Results: Twenty-six patients were included in the final analysis. The Ekblom-Bak test significantly overestimated peak oxygen consumption. Agreement between estimated and measured peak oxygen consumption was: bias = 4.3 mL/kg/min (limits of Conclusion: The Ekblom-Bak test overestimated peak oxygen consumption to such an extent that it cannot accurately assess cardiorespiratory fitness in patients with cardiovascular disease. Thus, the cardiopulmonary exercise test remains the test of choice.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Validity of the revised Ekblom Bak cycle ergometer test in adults
    Frida Björkman
    Elin Ekblom-Bak
    Örjan Ekblom
    Björn Ekblom
    European Journal of Applied Physiology, 2016, 116 : 1627 - 1638
  • [2] Validity of the revised Ekblom Bak cycle ergometer test in adults
    Bjorkman, Frida
    Ekblom-Bak, Elin
    Ekblom, Orjan
    Ekblom, Bjorn
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2016, 116 (09) : 1627 - 1638
  • [3] Criterion validity of the Ekblom-Bak and the Astrand submaximal test in an elderly population
    Vaisanen, Daniel
    Ekblom, Orjan
    Ekblom-Bak, Elin
    Andersson, Eva
    Nilsson, Jonna
    Ekblom, Maria
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2020, 120 (02) : 307 - 316
  • [4] Criterion validity of the Ekblom-Bak and the Åstrand submaximal test in an elderly population
    Daniel Väisänen
    Örjan Ekblom
    Elin Ekblom-Bak
    Eva Andersson
    Jonna Nilsson
    Maria Ekblom
    European Journal of Applied Physiology, 2020, 120 : 307 - 316
  • [5] Reference values for estimated VO2max by two submaximal cycle tests: the Åstrand-test and the Ekblom-Bak test
    Vaisanen, Daniel
    Ekblom, Bjorn
    Wallin, Peter
    Andersson, Gunnar
    Ekblom-Bak, Elin
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2024, 124 (06) : 1747 - 1756
  • [6] Comparison of the Ekblom-Bak Submaximal Test to a Maximal Test in a Cohort of Healthy Younger and Older Adults in the United States
    Schultz, Stephanie A.
    Byers, Jennifer
    Benzinger, Tammie L. S.
    Reeds, Dominic
    Vlassenko, Andrei G.
    Cade, W. Todd
    Goyal, Manu S.
    FRONTIERS IN PHYSIOLOGY, 2020, 11
  • [7] VALIDITY OF DIFFERENT ANAEROBIC TEST PROTOCOLS ON THE CYCLE ERGOMETER
    BACHL, N
    GRANTSCHAROV, N
    IWANOFF, I
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1985, 6 (04) : 245 - 245
  • [8] Validity and Reliability of the Lode Excalibur Sport Cycle Ergometer for the Wingate Anaerobic Test
    Lunn, William R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 25 - 25
  • [9] Validity and Reliability of the Lode Excalibur Sport Cycle Ergometer for the Wingate Anaerobic Test
    Lunn, William R.
    Axtell, Robert S.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2021, 35 (10) : 2894 - 2901
  • [10] Validity And Reliability Of The Ymca Submaximal Cycle Test Using An Electrically-braked Ergometer
    Kidd, Justin
    Luden, Nicholas D.
    Saunders, Michael J.
    Womack, Christopher J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 936 - 936