Underway mapping of coastal seawater pH using an automated shipboard analyzer with spectrophotometric detection

被引:0
|
作者
Li, Hangqian [1 ,2 ,5 ]
Wang, Shu [1 ,3 ]
Zheng, Shulu [1 ,2 ]
Fang, Tengyue [1 ,2 ]
Shu, Huilin [1 ,2 ]
Xu, Yi [1 ,4 ]
Guo, Xianghui [1 ,4 ]
Achterberg, Eric P. [5 ]
Zhan, Liyang [6 ]
Ma, Jian [1 ,2 ]
机构
[1] Xiamen Univ, State Key Lab Marine Environm Sci, Xiamen 361102, Peoples R China
[2] Xiamen Univ, Coll Environm & Ecol, Xiamen 361102, Peoples R China
[3] Hefei Univ Technol, Sch Resources & Environm Engn, Hefei 230009, Peoples R China
[4] Xiamen Univ, Coll Ocean & Earth Sci, Xiamen 361102, Peoples R China
[5] GEOMAR Helmholtz Ctr Ocean Res Kiel, Marine Biogeochem, Chem Oceanog, D-24148 Kiel, Germany
[6] Minist Nat Resources, Inst Oceanog 3, Key Lab Global Change & Marine Atmospher Chem, Xiamen, Peoples R China
关键词
Flow analysis; Ocean acidification; Underway analysis; Flash chromatography; High-precision spectrophotometric detection; pH; OCEAN-ACIDIFICATION; ION CONCENTRATION; CRESOL PURPLE; RIVER ESTUARY; CO2; ECOSYSTEMS; ALKALINITY; PRESSURE; CARBON;
D O I
10.1016/j.talanta.2024.126532
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of field-deployable methods and instruments for the measurement of pH and other carbonate parameters is important for the assessment of the marine carbon cycle, ocean acidification and marine carbon dioxide removal techniques. In this study, a high-precision fully automated integrated syringe-pump-based environmental-water analyzer for pH ( i SEA-pH) was developed. The pH is determined spectrophotometrically using purified indicator dye with a high precision (better than +/- 0.001) and high frequency (3.5 min/sample). For the short-term analysis, the measurement frequency was 18 h-1 , which revealed pH = 7.8148 +/- 0.0005 (n = 104) for aged surface seawater (S = 35) from the western Pacific. For long-term analysis, the measurement frequency was 2 h-1 for 4 days, and the results showed that pH = 7.8148 +/- 0.0010 (n = 200). Three commonly used pH indicators (meta-cresol purple, thymol blue and phenol red) were purified with improved flash chromatography procedures. The autonomous i SEA-pH can automatically correct for the influence of temperature, salinity and other factors on pH measurements to achieve rapid and accurate on-site measurements, which meet the "climate" goal of the Global Ocean Acidification Observing Network (uncertainty is +/- 0.003). Three identical i SEA-pH systems were developed and successfully applied in mesocosm experiments and several coastal and open ocean cruises with excellent in field performance.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Shipboard fluorometric flow analyzer for high-resolution underway measurement of ammonium in Seawater
    Amornthammarong, Natchanon
    Zhang, Jia-Zhong
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (04) : 1019 - 1026
  • [2] A high precision spectrophotometric method for on-line shipboard seawater pH measurements: the automated marine pH sensor (AMpS)
    Bellerby, RGJ
    Olsen, A
    Johannessen, T
    Croot, P
    [J]. TALANTA, 2002, 56 (01) : 61 - 69
  • [3] An automated system for spectrophotometric seawater pH measurements
    Carter, B. R.
    Radich, J. A.
    Doyle, H. L.
    Dickson, A. G.
    [J]. LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2013, 11 : 16 - 27
  • [4] Real-Time Underway Mapping of Nutrient Concentrations of Surface Seawater Using an Autonomous Flow Analyzer
    Fang, Tengyue
    Bo, Guangyong
    Zhang, Zijie
    Ma, Jian
    [J]. ANALYTICAL CHEMISTRY, 2022, 94 (32) : 11307 - 11314
  • [5] A coastal surface seawater analyzer for nitrogenous nutrient mapping
    Masserini, Robert T., Jr.
    Fanning, Kent A.
    Hendrix, Steven A.
    Kleiman, Brittany M.
    [J]. CONTINENTAL SHELF RESEARCH, 2017, 150 : 48 - 56
  • [6] Spectrophotometric high-precision seawater pH determination for use in underway measuring systems
    Assmann, S.
    Frank, C.
    Koertzinger, A.
    [J]. OCEAN SCIENCE, 2011, 7 (05) : 597 - 607
  • [7] Automated spectrophotometric determination of carbonate ion concentration in seawater using a portable syringe pump based analyzer
    Shangguan, Qipei
    Shu, Huilin
    Li, Peicong
    Lin, Kunning
    Byrne, Robert H.
    Li, Quanlong
    Yuan, Dongxing
    Ma, Jian
    [J]. MARINE CHEMISTRY, 2019, 209 : 120 - 127
  • [8] Spectrophotometric loop flow analyzer for high-precision measurement of seawater pH
    Cao, Lu
    Qi, Di
    Li, Quanlong
    Yang, Bo
    Zhang, Yunyan
    Zhang, Shuwei
    Qi, Shengbo
    Zhang, Yingying
    Liu, Yan
    [J]. TALANTA, 2021, 224
  • [9] Field Application of Automated Spectrophotometric Analyzer for High-Resolution In Situ Monitoring of pH in Dynamic Estuarine and Coastal Waters
    Nehir, Muenevver
    Esposito, Mario
    Loucaides, Socratis
    Achterberg, Eric P.
    [J]. FRONTIERS IN MARINE SCIENCE, 2022, 9
  • [10] Automated Spectrophotometric Analyzer for Rapid Single-Point Titration of Seawater Total Alkalinity
    Li, Quanlong
    Wang, Fengzhen
    Wang, Zhaohui Aleck
    Yuan, Dongxing
    Dai, Minhan
    Chen, Jinshun
    Dai, Junwei
    Hoering, Katherine A.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (19) : 11139 - 11146