Realization of Higher Resolution Charge Detection Mass Spectrometry

被引:2
|
作者
Reitenbach, David W. [1 ]
Botamanenko, Daniel Y. [2 ]
Miller, Lohra M. [2 ]
Jarrold, Martin F. [1 ]
机构
[1] Indiana Univ, Chem Dept, Bloomington, IN 47405 USA
[2] Megadalton Solut Inc, Bloomington, IN 47401 USA
基金
美国国家卫生研究院;
关键词
INDIVIDUAL IONS; ANALYZER; TRAP;
D O I
10.1021/acs.analchem.4c03267
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Charge detection mass spectrometry (CD-MS) allows mass distributions to be measured for heterogeneous samples that cannot be analyzed by conventional MS. With CD-MS, the m/z and charge are measured for individual ions using a detection cylinder embedded in an electrostatic linear ion trap (ELIT). Imprecision in both the m/z and charge measurements contribute to the mass resolution. However, if the charge can be measured with a precision of <0.2 e the charge state can be assigned with a low error rate and the mass resolving power only depends on the m/z resolution. Prior to this work, the best resolving power demonstrated experimentally for CD-MS was 700. Here we demonstrate a resolving power of >14,600, 20-times higher than the previous best. Trajectory simulations were used to optimize the geometry and electrostatic potentials of the ELIT. We found conditions where the energy dependence of the oscillation frequency becomes parabolic, and then operated with a nominal ion energy at the minimum of the parabola. The 14,600 resolving power was obtained with a beam collimator before the ELIT. With the collimator removed, the resolving power of the optimized ELIT is 7300, which is still an order of magnitude higher than the previous best. The resolving power was demonstrated by resolving the isotope distributions for peptides and proteins. High resolution CD-MS measurements were then used to resolve the glycans on a monoclonal antibody and applied to the analysis of hepatitis B virus capsids. The results indicate that procedures for adduct removal need to be improved for the full benefit of the higher resolving power to be realized for higher mass species. However, these results represent a key step toward using CD-MS to analyze very complex protein mixtures where charge states are not well resolved in the m/z spectrum because of congestion from numerous overlapping peaks.
引用
收藏
页码:14060 / 14067
页数:8
相关论文
共 50 条
  • [1] Higher Resolution Charge Detection Mass Spectrometry
    Todd, Aaron R.
    Barnes, Lauren F.
    Young, Kim
    Zlotnick, Adam
    Jarrold, Martin F.
    ANALYTICAL CHEMISTRY, 2020, 92 (16) : 11357 - 11364
  • [2] Resolution of Lipoprotein Subclasses by Charge Detection Mass Spectrometry
    Lutomski, Corinne A.
    Gordon, Scott M.
    Remaley, Alan T.
    Jarrold, Martin F.
    ANALYTICAL CHEMISTRY, 2018, 90 (11) : 6353 - 6356
  • [3] Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry
    Harper, Conner C.
    Miller, Zachary M.
    Lee, Hyuncheol
    Bischoff, Amanda J.
    Francis, Matthew B.
    Schaffer, David V.
    Williams, Evan R.
    ANALYTICAL CHEMISTRY, 2022, 94 (33) : 11703 - 11712
  • [4] A Discrete Realization of Higher Resolution Phase Detection
    Liao, Ping-Sung
    Lee, Chien-Hua
    GREEN POWER, MATERIALS AND MANUFACTURING TECHNOLOGY AND APPLICATIONS II, 2012, 214 : 882 - 886
  • [5] Probing higher order multimers of pyruvate kinase with charge detection mass spectrometry
    Pierson, Elizabeth E.
    Keifer, David Z.
    Contino, Nathan C.
    Jarrold, Martin F.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2013, 337 : 50 - 56
  • [6] Charge Detection Mass Spectrometry with Resolved Charge States
    Contino, Nathan C.
    Pierson, Elizabeth E.
    Keifer, David Z.
    Jarrold, Martin F.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (01) : 101 - 108
  • [7] Apodization Specific Fitting for Improved Resolution, Charge Measurement, and Data Analysis Speed in Charge Detection Mass Spectrometry
    Miller, Zachary M.
    Harper, Conner C.
    Lee, Hyuncheol
    Bischoff, Amanda J.
    Francis, Matthew B.
    V. Schaffer, David
    Williams, Evan R.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2022, 33 (11) : 2129 - 2137
  • [8] Supercharging and charge detection in native mass spectrometry
    Williams, Evan R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 246
  • [9] Charge detection mass spectrometry steps up
    Arnaud, Celia Henry
    CHEMICAL & ENGINEERING NEWS, 2019, 97 (36) : 23 - 25
  • [10] Charge Detection Mass Spectrometry with Almost Perfect Charge Accuracy
    Keifer, David Z.
    Shinholt, Deven L.
    Jarrold, Martin F.
    ANALYTICAL CHEMISTRY, 2015, 87 (20) : 10330 - 10337