Dual and Multi-Target Cone-Beam X-ray Luminescence Computed Tomography Based on the DeepCB-XLCT Network

被引:0
|
作者
Liu, Tianshuai [1 ,2 ]
Huang, Shien [1 ,3 ]
Li, Ruijing [1 ,2 ]
Gao, Peng [1 ,2 ]
Li, Wangyang [1 ,2 ]
Lu, Hongbing [1 ,2 ]
Song, Yonghong [3 ]
Rong, Junyan [1 ,2 ]
机构
[1] Fourth Mil Med Univ, Biomed Engn Dept, Xian 710032, Peoples R China
[2] Shaanxi Prov Key Lab Bioelectromagnet Detect & Int, Xian 710032, Peoples R China
[3] Xi An Jiao Tong Univ, Sch Software Engn, Xian 710049, Peoples R China
来源
BIOENGINEERING-BASEL | 2024年 / 11卷 / 09期
基金
美国国家科学基金会;
关键词
cone-beam X-ray luminescence computed tomography; deep learning reconstruction; spatial resolution; contrast sensitivity; multi-targets;
D O I
10.3390/bioengineering11090874
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background and Objective: Emerging as a hybrid imaging modality, cone-beam X-ray luminescence computed tomography (CB-XLCT) has been developed using X-ray-excitable nanoparticles. In contrast to conventional bio-optical imaging techniques like bioluminescence tomography (BLT) and fluorescence molecular tomography (FMT), CB-XLCT offers the advantage of greater imaging depth while significantly reducing interference from autofluorescence and background fluorescence, owing to its utilization of X-ray-excited nanoparticles. However, due to the intricate excitation process and extensive light scattering within biological tissues, the inverse problem of CB-XLCT is fundamentally ill-conditioned. Methods: An end-to-end three-dimensional deep encoder-decoder network, termed DeepCB-XLCT, is introduced to improve the quality of CB-XLCT reconstructions. This network directly establishes a nonlinear mapping between the distribution of internal X-ray-excitable nanoparticles and the corresponding boundary fluorescent signals. To improve the fidelity of target shape restoration, the structural similarity loss (SSIM) was incorporated into the objective function of the DeepCB-XLCT network. Additionally, a loss term specifically for target regions was introduced to improve the network's emphasis on the areas of interest. As a result, the inaccuracies in reconstruction caused by the simplified linear model used in conventional methods can be effectively minimized by the proposed DeepCB-XLCT method. Results and Conclusions: Numerical simulations, phantom experiments, and in vivo experiments with two targets were performed, revealing that the DeepCB-XLCT network enhances reconstruction accuracy regarding contrast-to-noise ratio and shape similarity when compared to traditional methods. In addition, the findings from the XLCT tomographic images involving three targets demonstrate its potential for multi-target CB-XLCT imaging.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Cone-beam x-ray luminescence computed tomography (CB-XLCT) prototype development and performance evaluation
    Wang, Yu-Hong
    Jin, David Shih-Chun
    Wu, Tian-Yu
    Shen, Chieh
    Chen, Jyh-Cheng
    Tseng, Snow H.
    Liu, Tse-Ying
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (03):
  • [2] Cone-beam x-ray luminescence computed tomography based on x-ray absorption dosage
    Liu, Tianshuai
    Rong, Junyan
    Gao, Peng
    Zhang, Wenli
    Liu, Wenlei
    Zhang, Yuanke
    Lu, Hongbing
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (02)
  • [3] Multi-mounted X-ray cone-beam computed tomography
    Fu, Jian
    Wang, Jingzheng
    Guo, Wei
    Peng, Peng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 888 : 119 - 125
  • [4] Background luminescence in x-ray luminescence computed tomography (XLCT) imaging
    Lun, Michael C.
    Li, Changqing
    APPLIED OPTICS, 2019, 58 (04) : 1084 - 1092
  • [5] Adaptive shrinking reconstruction framework for cone-beam X-ray luminescence computed tomography
    Zhang, Haibo
    Huang, Xiaodong
    Zhou, Mingquan
    Geng, Guohua
    He, Xiaowei
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (07) : 3717 - 3732
  • [6] Cone-beam X-ray luminescence computed tomography based on MLEM with adaptive FISTA initial image
    Liu, Tianshuai
    Ruan, Jiabin
    Rong, Junyan
    Hao, Wenqing
    Li, Wangyang
    Li, Ruijing
    Zhan, Yonghua
    Lu, Hongbing
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 229
  • [7] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    APPLIED PHYSICS LETTERS, 2014, 105 (19)
  • [8] Cone Beam X-ray Luminescence Computed Tomography Based on Bayesian Method
    Zhang, Guanglei
    Liu, Fei
    Liu, Jie
    Luo, Jianwen
    Xie, Yaoqin
    Bai, Jing
    Xing, Lei
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (01) : 225 - 235
  • [9] MLEM reconstruction with specific initial image for cone-beam x-ray luminescence computed tomography
    Ruan, Jiabin
    Gao, Peng
    Liu, Tianshuai
    Zhan, Yonghua
    Lu, Hongbing
    Rong, Junyan
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [10] Excitation-resolved cone-beam x-ray luminescence tomography
    Liu, Xin
    Liao, Qimei
    Wang, Hongkai
    Yan, Zhuangzhi
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (07)