Identification of bile acids in snake bile by hydrogen/deuterium exchange mass spectrometry and quantitative structure-retention relationship analysis

被引:0
|
作者
Wei, Yinyu [1 ,2 ]
Zhu, Chenyue [1 ]
Ye, Xinyuan [1 ]
Wang, Chenxi [1 ]
Qi, Meiling [1 ]
Chen, Yi [1 ]
Du, Zhifeng [1 ]
Li, Sen [2 ]
Jiang, Hongliang [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Sch Pharm, Wuhan 430030, Peoples R China
[2] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Pharm, Wuhan 430030, Peoples R China
关键词
Bile acids; Qualitative analysis; LC-MS/MS; Hydrogen-deuterium exchange; Quantitative structure-retention relationship; PERFORMANCE LIQUID-CHROMATOGRAPHY; TIME; METABOLITES;
D O I
10.1016/j.chroma.2024.465384
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Natural bile acids, a class of steroids with a valeric acid side chain at the C-17 position, present significant challenges in separation and analysis due to structural similarities, isomerism, and large polarity differences. Therefore, advanced analytical methods are essential for the accurate identification and quantification of bile acids. This study conducted a comprehensive qualitative analysis of bile acids by integrating liquid chromatography-tandem mass spectrometry (LC-MS/MS), hydrogen-deuterium exchange tandem mass spectrometry (HDX-MS/MS), and quantitative structure-retention relationship (QSRR) methods. Firstly, LC-MS/MS conditions were optimized to enhance chromatographic separation and improve the reliability of characteristic fragment ions. MS/MS fragmentation rules for bile acids were derived from the mass spectral data of bile acid standards and validated through HDX-MS/MS experiments. Secondly, potential bile acids in snake bile were identified based on these validated fragmentation rules, and a QSRR model was established to predict the retention times of the proposed structures. Thirdly, HDX-MS/MS was applied to assist in identifying bile acid isomers. Finally, a total of 150 bile acids, including 11 free bile acids (free BA), 5 glyco-bile acids (GBA) and 134 tauro-bile acids (TBA), were detected in snake bile. Thirteen bile acids were accurately characterized by comparing their retention time and MS/MS spectra with standards. Forty-nine bile acids were reasonably annotated using the QSRR model and HDX-MS/MS. This study is notable for being the first to utilize the QSRR and HDX-MS/MS techniques for the annotation of bile acids in snake bile, providing a robust framework for the structural elucidation of these compounds.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Identification of endogenous carbonyl steroids in human serum by chemical derivatization, hydrogen/deuterium exchange mass spectrometry and the quantitative structure-retention relationship
    Wei, Yinyu
    Sun, Yi
    Jia, Shuailong
    Yan, Pan
    Xiong, Chaomei
    Qi, Meiling
    Wang, Chenxi
    Du, Zhifeng
    Jiang, Hongliang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1226
  • [2] Quantitative Hydrogen/Deuterium Exchange Mass Spectrometry
    Hamuro, Yoshitomo
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2021, 32 (12) : 2711 - 2727
  • [3] Quantitative Structure-Retention Relationship Prediction of Kovats Retention Index of Some Organic Acids
    Fatemi, M. H.
    Elyasi, M.
    ACTA CHROMATOGRAPHICA, 2013, 25 (03) : 411 - 422
  • [4] Hydrogen/deuterium exchange mass spectrometry analysis of protein aggregates
    Kheterpal, Indu
    Cook, Kelsey D.
    Wetzel, Ronald
    AMYLOID, PRIONS, AND OTHER PROTEIN AGGREGATES, PT C, 2006, 413 : 140 - 166
  • [5] THE UNCOMMON BILE-ACIDS IN BILE - MASS-SPECTROMETRY IDENTIFICATION OF BILIARY BILE-ACIDS IN GALLSTONE PATIENTS BEFORE AND DURING TREATMENT WITH CHENODEOXYCHOLIC ACID
    STELLAARD, F
    KLEIN, PD
    HOFMANN, AF
    LACHIN, JM
    GASTROENTEROLOGY, 1983, 84 (05) : 1398 - 1398
  • [6] Rapid identification of bile acids in snake bile using ultrahigh-performance liquid chromatography with electrospray ionization quadrupole time-of-flight tandem mass spectrometry
    Zhang, Jie
    Peng, Jiao
    Chen, Xiaoyong
    Gong, Yajun
    Wan, Lesheng
    Gao, Fei
    Gan, Suran
    Wei, Feng
    Ma, Shuangcheng
    Chen, Jiachun
    Nie, Jing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1036 : 157 - 169
  • [7] Indirect quantitative structure-retention relationship for steroid identification: A chemometric challenge at "Chimiometrie 2016"
    Randazzo, Giuseppe Marco
    Vigneau, Evelyne
    Courcoux, Philippe
    Harrouet, Corentin
    Lijour, Yves
    Dardenne, Pierre
    Boccard, Julien
    Rudaz, Serge
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2017, 160 : 52 - 58
  • [8] Use of cluster and principal component analysis in quantitative structure-retention relationship study
    Forgacs, E
    Cserhati, T
    ANALYTICA CHIMICA ACTA, 1997, 348 (1-3) : 481 - 487
  • [9] Structure-retention correlation of isomeric bile acids in inclusion high-performance liquid chromatography with methyl β-cyclodextrin
    Momose, T
    Yamaguchi, Y
    Iida, T
    Goto, J
    Nambara, T
    LIPIDS, 1998, 33 (01) : 101 - 108
  • [10] IDENTIFICATION OF STEROLS AND BILE-ACIDS BY COMPUTERIZED GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    ELLIOTT, WH
    LIPIDS, 1980, 15 (09) : 764 - 769