A high efficiency adaptive ultrasonic array imaging method with sensitivity correction for curved structures

被引:1
|
作者
Wang, Jun [1 ]
Zhou, Zhenggan [1 ,2 ]
Li, Yang [2 ]
Yang, Gongpeng [1 ]
Zhou, Wenbin [1 ,3 ]
机构
[1] Beihang Univ, Sch Mech Engn & Automat, Beijing 100191, Peoples R China
[2] Beihang Univ, Ningbo Inst Technol, Ningbo 315800, Peoples R China
[3] Beihang Univ, Dept German, 37 Xueyuan Rd, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
Non-destructive testing; Ultrasonic array; Curved structure; Adaptive imaging; High efficiency; COMPONENTS; ALGORITHMS;
D O I
10.1016/j.measurement.2024.115322
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The adaptive ultrasonic array imaging can be used for defects detection with unknown sample profile. To solve the problems of low computational efficiency and difficult quantitative evaluation in detection, this paper presents a high efficiency adaptive ultrasonic array imaging method with sensitivity correction. For surface reconstruction, the vector coherence technique has been used to correct the plane wave imaging of sample surface with single emission, which improves the imaging quality and efficiency. A robust fitting method is proposed based on Random Sample Consensus algorithm to reconstruct the surface after the surface pixel recognition. To reduce the beam path calculation time, a prediction search method is developed, whose time consumption is reduced by 97.2 % compared with the global traversal method with the same results. The sensitivity correction algorithm is proposed based on the ultrasonic propagation model, which makes the amplitude difference of defects in different regions is less than 0.8 dB.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] An Adaptive Manifold Error Correction Method for Curved Array
    Zeng, Guilan
    Jiang, Yanwen
    Fan, Hongqi
    Feng, Yilun
    Wang, Min
    2022 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY (ICMMT), 2022,
  • [2] Probe Standoff Optimization Method for Phased Array Ultrasonic TFM Imaging of Curved Parts
    Mansur Rodrigues Filho, Jorge Franklin
    Belanger, Pierre
    SENSORS, 2021, 21 (19)
  • [3] Adaptive Gradient Projection Correction Method for Resistivity Array Imaging Logging
    Tian, Yutong
    Yang, Haining
    Yi, Shijia
    Li, Tingjun
    Li, Na
    IEEE SENSORS JOURNAL, 2024, 24 (07) : 11014 - 11023
  • [4] High-resolution phased array ultrasonic imaging with propagator method
    Zhang, Xiaofei
    Chen, Han
    ICIC Express Letters, 2014, 8 (05): : 1433 - 1438
  • [5] Improved Ultrasonic SAFT Imaging of Flaws in Structures with Curved Surfaces
    Hirose, Sohichi
    Nishimoto, Seitaro
    Maruyama, Taizo
    Nagata, Yasuaki
    40TH ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION: INCORPORATING THE 10TH INTERNATIONAL CONFERENCE ON BARKHAUSEN NOISE AND MICROMAGNETIC TESTING, VOLS 33A & 33B, 2014, 1581 : 36 - 41
  • [6] Online evolution of a phased array for ultrasonic imaging by a novel adaptive data acquisition method
    Lukacs, Peter
    Stratoudaki, Theodosia
    Davis, Geo
    Gachagan, Anthony
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [8] Total Focusing Method-Based Ultrasonic Phased Array Imaging in Thick Structures
    Sumana
    Kumar, Anish
    JOURNAL OF NONDESTRUCTIVE EVALUATION, DIAGNOSTICS AND PROGNOSTICS OF ENGINEERING SYSTEMS, 2021, 4 (04):
  • [9] High efficiency ultrasonic imaging system
    Zhang, Guangming
    Mei, Lin
    Tan, Zhen
    Wang, Yuwen
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 1999, 20 (06): : 586 - 588
  • [10] An efficient ultrasonic wavenumber-domain plane wave imaging method towards the inspection of curved structures
    Chang, Zhixuan
    Wu, Eryong
    Xu, Xintao
    Wu, Shiwei
    Yang, Keji
    Chen, Jian
    Jin, Haoran
    ULTRASONICS, 2024, 143