Electro-Thermal Simulation and Evaluation of Transition Edge Sensor X-ray Microcalorimeter with Mushroom-Type Absorber

被引:1
|
作者
Ota, Ryo [1 ,2 ]
Tanaka, Keita [1 ,2 ]
Hayashi, Tasuku [3 ,4 ,5 ]
Miyagawa, Rikuta [6 ]
Yagi, Yuta [1 ,2 ]
Yamasaki, Noriko Y. [1 ,2 ,5 ]
Mitsuda, Kazushisa [1 ,4 ,5 ]
机构
[1] Japan Aerosp Explorat Agcy JAXA, Dept Space Astron & Astrophys, Inst Space & Astronaut Sci ISAS, 3-1-1 Yoshinodai,Chuo Ku, Sagamihara, Kanagawa 2525210, Japan
[2] Univ Tokyo, Sch Sci, Dept Phys, 7-3-1 Hongo,Bunkyo Ku, Tokyo 1130033, Japan
[3] Rikkyo Univ, Dept Phys, 3-34-1 Nishi Ikebukuro,Toshima Ku, Tokyo 1718501, Japan
[4] Natl Astron Observ Japan NAOJ, Adv Technol Ctr, 2-21-1 Osawa, Mitaka, Tokyo 1818588, Japan
[5] KEK, Int Ctr Quantum Field Measurement Syst Studies Uni, 1-1 Oho, Tsukuba, Ibaraki 3003256, Japan
[6] Japan Aerosp Explorat Agcy JAXA, Tanegashima Space Ctr, Minamitane, Kagoshima 8913793, Japan
关键词
X-ray; Superconducting; Sensor; TES; Simulation; COMSOL; HEAT;
D O I
10.1007/s10909-024-03190-2
中图分类号
O59 [应用物理学];
学科分类号
摘要
High-efficiency microcalorimeter arrays are required as imaging spectroscopy for X-ray microscopy in general and for astrophysics. We have developed in-house an array of Transition Edge Sensor (TES) X-ray microcalorimeters with mushroom-type absorbers which have a large area of 260 mu m\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$260\,\upmu \hbox {m}$$\end{document} square with multiple support stems. Insufficient thermal conductivity may degrade the energy resolution. We construct a 3D FEM simulation with thermal conduction and electric feedback circuit of TES. Estimated physical parameters were incorporated into the simulation to reproduce the measured pulse waveforms. As a result, the effect of the large absorber on the degradation of energy resolution was small for the mushroom-type absorber TES calorimeter.
引用
收藏
页码:366 / 373
页数:8
相关论文
共 50 条
  • [1] X-Ray Response of a Transition Edge Sensor Microcalorimeter With a Mushroom-Shaped Absorber
    Ezaki, S.
    Maehata, K.
    Iyomoto, N.
    Maeda, M.
    Hara, T.
    Mitsuda, K.
    Tanaka, K.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2015, 25 (03) : 1 - 4
  • [2] Modelling the electro-thermal response of superconducting transition-edge X-ray sensors
    Roth, P
    Fraser, GW
    Holland, AD
    Trowell, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 443 (2-3): : 351 - 363
  • [3] Quantitative analysis with the transition edge sensor microcalorimeter X-ray detector
    Jach, Terrence
    Ritchie, Nicholas
    Ullom, Joel
    Beall, James A.
    POWDER DIFFRACTION, 2007, 22 (02) : 138 - 141
  • [4] Development of an X-ray imaging microcalorimeter with a pixel-type Ir transition edge sensor
    Ohno, M
    Takahashi, H
    Fukuda, D
    Kunieda, Y
    Inou, T
    Noguchi, Y
    Pressler, H
    Hirayama, F
    Ohkubo, M
    Ataka, M
    Shimizu, HM
    Nakazawa, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 265 - 268
  • [5] Transition Edge Sensor Microcalorimeter With Bismuth Absorber for Gamma-Ray Measurement
    Tsuruta, Tetsuya
    Iyomoto, Naoko
    Asagawa, Shinya
    Hamamura, Yukino
    Nishida, Yoshiki
    Maehata, Keisuke
    Mitsuda, Kazuhisa
    Hayashi, Tasuku
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2021, 31 (05)
  • [6] Absorber Materials for Transition-Edge Sensor X-ray Microcalorimeters
    A.-D. Brown
    S. R. Bandler
    R. Brekosky
    J. A. Chervenak
    E. Figueroa-Feliciano
    F. Finkbeiner
    N. Iyomoto
    R. L. Kelley
    C. A. Kilbourne
    F. S. Porter
    S. Smith
    T. Saab
    J. Sadleir
    Journal of Low Temperature Physics, 2008, 151 : 413 - 417
  • [7] Absorber materials for transition-edge sensor X-ray microcalorimeters
    Brown, A. -D.
    Bandler, S. R.
    Brekosky, R.
    Chervenak, J. A.
    Figueroa-Feliciano, E.
    Finkbeiner, F.
    Iyomoto, N.
    Kelley, R. L.
    Kilbourne, C. A.
    Porter, F. S.
    Smith, S.
    Saab, T.
    Sadleir, J.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2008, 151 (1-2) : 413 - 417
  • [8] X-ray Microcalorimeter Based on Superconducting Transition Edge Sensors
    Masashi Ohno
    Hiroyuki Takahashi
    R. M. Thushara Damayanthi
    Yasuhiro Minamikawa
    Fumiakira Mori
    Analytical Sciences, 2008, 24 : 11 - 14
  • [9] X-ray microcalorimeter based on superconducting transition edge sensors
    Ohno, Masashi
    Takahashi, Hiroyuki
    Damayanthi, R. M. Thushara
    Minamikawa, Yasuhiro
    Mori, Fumiakira
    ANALYTICAL SCIENCES, 2008, 24 (01) : 11 - 14
  • [10] X-ray detection using a superconducting transition-edge sensor microcalorimeter with electrothermal feedback
    Irwin, KD
    Hilton, GC
    Wollman, DA
    Martinis, JM
    APPLIED PHYSICS LETTERS, 1996, 69 (13) : 1945 - 1947