Optical coherence tomography predictors of clinical outcomes after stent implantation: the ILUMIEN IV trial

被引:5
|
作者
Landmesser, Ulf [1 ,2 ,3 ]
Ali, Ziad A. [4 ,5 ]
Maehara, Akiko [5 ,6 ]
Matsumura, Mitsuaki [5 ]
Shlofmitz, Richard A. [4 ]
Guagliumi, Giulio [7 ]
Price, Matthew J. [8 ]
Hill, Jonathan M. [9 ]
Akasaka, Takashi [10 ]
Prati, Francesco [11 ]
Bezerra, Hiram G. [12 ]
Wijns, William [13 ]
Leistner, David [14 ,15 ]
Canova, Paolo [16 ]
Alfonso, Fernando [17 ]
Fabbiocchi, Franco [7 ]
Calligaris, Giuseppe [18 ]
Oemrawsingh, Rohit M. [19 ]
Achenbach, Stephan [20 ]
Trani, Carlo [21 ]
Singh, Balbir [22 ]
McGreevy, Robert J. [23 ]
McNutt, Robert W. [23 ]
Ying, Shih-Wa [23 ]
Buccola, Jana [23 ]
Stone, Gregg W. [24 ]
机构
[1] Charite Univ med Berlin, Dept Cardiol Angiol & Intens Care Med, Deutsch Herzzentrum Charite, Berlin, Germany
[2] Berlin Inst Hlth, Berlin, Germany
[3] German Ctr Cardiovasc Res, Berlin, Germany
[4] St Francis Hosp, Roslyn, NY USA
[5] Cardiovasc Res Fdn, New York, NY USA
[6] Columbia Univ, Ctr Intervent Cardiovasc Care, New York, NY USA
[7] IRCCS Galeazzi St Ambrogio Hosp, Milan, Italy
[8] Scripps Clin, Div Cardiovasc Dis, La Jolla, CA USA
[9] Royal Brompton Hosp, London, England
[10] Wakayama Med Univ, Wakayama, Japan
[11] St Camillus Int Univ Hlth Sci, CLI Fdn, Rome, Italy
[12] Tampa Gen Hosp, Tampa, FL USA
[13] Univ Galway, Lambe Inst Translat Medehance Spicine & Curam, Galway, Ireland
[14] Goethe Univ Hosp, Dept Med, Cardiol, Frankfurt, Germany
[15] German Ctr Cardiovasc Res DZHK, Partner Site RheinMain, Frankfurt, Germany
[16] Osped Papa Giovanni XXIII, Bergamo, Italy
[17] Hosp Univ La Princesa, Cardiol Dept, IIS IP, CIBERCV, Madrid, Spain
[18] Univ Milan, Dept Cardiovasc Sci, Milan, Italy
[19] Albert Schweitzer Ziekenhuis, Dordrecht, Netherlands
[20] Friedrich Alexander Univ Erlangen Nurnberg, Dept Cardiol, Erlangen, Germany
[21] Fdn Policlin Univ A Gemelli, Rome, Italy
[22] Max Super Specialty Hosp, New Delhi, India
[23] Abbott Vasc, Santa Clara, CA USA
[24] Icahn Sch Med Mt Sinai, Zena & Michael A Wiener Cardiovasc Inst, 1 Gustave L Levy Pl, New York, NY 10029 USA
关键词
Optical coherence tomography; Percutaneous coronary intervention; Stent; Prognosis; INTRAVASCULAR ULTRASOUND; IMPACT; OCT; PCI;
D O I
10.1093/eurheartj/ehae521
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Aims Observational registries have suggested that optical coherence tomography (OCT) imaging-derived parameters may predict adverse events after drug-eluting stent (DES) implantation. The present analysis sought to determine the OCT predictors of clinical outcomes from the large-scale ILUMIEN IV trial. Methods ILUMIEN IV was a prospective, single-blind trial of 2487 patients with diabetes or high-risk lesions randomized to OCT-guided versus angiography-guided DES implantation. All patients underwent final OCT imaging (blinded in the angiography-guided arm). From more than 20 candidates, the independent OCT predictors of 2-year target lesion failure (TLF; the primary endpoint), cardiac death or target-vessel myocardial infarction (TV-MI), ischaemia-driven target lesion revascularization (ID-TLR), and stent thrombosis were analysed by multivariable Cox proportional hazard regression in single treated lesions. Results A total of 2128 patients had a single treated lesion with core laboratory-analysed final OCT. The 2-year Kaplan-Meier rates of TLF, cardiac death or TV-MI, ID-TLR, and stent thrombosis were 6.3% (n = 130), 3.3% (n = 68), 4.3% (n = 87), and 0.9% (n = 18), respectively. The independent predictors of 2-year TLF were a smaller minimal stent area (per 1 mm2 increase: hazard ratio 0.76, 95% confidence interval 0.68-0.89, P < .0001) and proximal edge dissection (hazard ratio 1.77, 95% confidence interval 1.20-2.62, P = .004). The independent predictors of cardiac death or TV-MI were smaller minimal stent area and longer stent length; of ID-TLR were smaller intra-stent flow area and proximal edge dissection; and of stent thrombosis was smaller minimal stent expansion. Conclusions In the ILUMIEN IV trial, the most important OCT-derived post-DES predictors of both safety and effectiveness outcomes were parameters related to stent area, expansion and flow, proximal edge dissection, and stent length.
引用
收藏
页码:4630 / 4643
页数:14
相关论文
共 50 条
  • [1] Incidences, Predictors, and Clinical Outcomes of Acute and Late Stent Malapposition Detected by Optical Coherence Tomography After Drug-Eluting Stent Implantation
    Im, Eui
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Shin, Dong-Ho
    Kim, Jung-Sun
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (01) : 88 - 96
  • [2] Optical coherence tomography-guided coronary stent implantation compared to angiography: a multicentre randomised trial in PCI - design and rationale of ILUMIEN IV: OPTIMAL PCI
    Ali, Ziad A.
    Landmesser, Ulf
    Galougahi, Keyvan Karimi
    Maehara, Akiko
    Matsumura, Mitsuaki
    Shlofmitz, Richard A.
    Guagliumi, Giulio
    Price, Matthew J.
    Hill, Jonathan M.
    Akasaka, Takashi
    Prati, Francesco
    Bezerra, Hiram G.
    Wijns, William
    Mintz, Gary S.
    Ben-Yehuda, Ori
    McGreevy, Robert J.
    Zhang, Zhen
    Rapoza, Richard R.
    West, Nick E. J.
    Stone, Gregg W.
    EUROINTERVENTION, 2021, 16 (13) : 1092 - 1099
  • [3] Optical coherence tomography predictors for edge restenosis after everolimus-eluting stent implantation
    Ino, Yasushi
    Kubo, Takashi
    Matsuo, Yoshiki
    Kameyama, Takeyoshi
    Emori, Hiroki
    Kitabata, Hironori
    Kuroi, Akio
    Yamaguchi, Tomoyuki
    Aoki, Hiroshi
    Nishiguchi, Tsuyoshi
    Yamano, Takashi
    Tanaka, Atsushi
    Hozumi, Takeshi
    Akasaka, Takashi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B234 - B235
  • [4] Optical Coherence Tomography Predictors for Edge Restenosis After Everolimus-Eluting Stent Implantation
    Ino, Yasushi
    Kubo, Takashi
    Matsuo, Yoshiki
    Yamaguchi, Tomoyuki
    Shiono, Yasutsugu
    Shimamura, Kunihiro
    Katayama, Yosuke
    Nakamura, Tomoko
    Aoki, Hiroshi
    Taruya, Akira
    Nishiguchi, Tsuyoshi
    Satogami, Keisuke
    Yamano, Takashi
    Kameyama, Takeyoshi
    Orii, Makoto
    Ota, Shingo
    Kuroi, Akio
    Kitabata, Hironori
    Tanaka, Atsushi
    Hozumi, Takeshi
    Akasaka, Takashi
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (10)
  • [5] The predictors of neoatherosclerosis after drug-eluting stent implantation evaluated by optical coherence tomography
    Zheng, B. Z.
    Li, S. G. L.
    Chen, M. C.
    EUROPEAN HEART JOURNAL, 2018, 39 : 543 - 543
  • [6] The Clinical Implication of Neointimal Characteristics Observed in Optical Coherence Tomography after Stent Implantation
    Lee, Jung-Hee
    Kim, Jung-Sun
    Shin, Dong-Ho
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B144 - B144
  • [7] Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial
    Ali, Ziad A.
    Maehara, Akiko
    Genereux, Philippe
    Shlofmitz, Richard A.
    Fabbiocchi, Franco
    Nazif, Tamim M.
    Guagliumi, Giulio
    Meraj, Perwaiz M.
    Alfonso, Fernando
    Samady, Habib
    Akasaka, Takashi
    Carlson, Eric B.
    Leesar, Massoud A.
    Matsumura, Mitsuaki
    Ozan, Melek Ozgu
    Mintz, Gary S.
    Ben-Yehuda, Ori
    Stone, Gregg W.
    LANCET, 2016, 388 (10060): : 2618 - 2628
  • [8] Outcomes of optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation: one-year results from the ILUMIEN III: OPTIMIZE PCI trial
    Ali, Ziad A.
    Galougahi, Keyvan Karimi
    Maehara, Akiko
    Shlofmitz, Richard A.
    Fabbiocchi, Franco
    Guagliumi, Giulio
    Alfonso, Fernando
    Akasaka, Takashi
    Matsumura, Mitsuaki
    Mintz, Gary S.
    Ben-Yehuda, Ori
    Zhang, Zhen
    Rapoza, Richard R.
    West, Nick E. J.
    Stone, Gregg W.
    EUROINTERVENTION, 2021, 16 (13) : 1085 - 1091
  • [9] Clinical Outcomes of Acute Abnormal Findings After Drug-Eluting Stent Implantation: Optical Coherence Tomography Analysis
    Yu, Cheol Woong
    Cho, Jae Young
    Roh, Seung Young
    Joo, Hyung Joon
    Park, Jae Hyoung
    Hong, Soon Jun
    Lim, Do-Sun
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B111 - B111
  • [10] Evaluation of aneurysm after coronary stent implantation by optical coherence tomography
    Karabay, Can Yucel
    Kocabay, Gonenc
    Tasar, Onur
    Kalayci, Arzu
    Guler, Ahmet
    Kirma, Cevat
    KARDIOLOGIA POLSKA, 2013, 71 (06) : 659 - 659