Biomechanical analysis of four different meniscus suturing techniques for posterior meniscal root pull-out repair: A human cadaveric study

被引:0
|
作者
Chang, Ting-Yu [1 ]
Yang, Tai-Hua [1 ,2 ]
Lin, Kuan-Yu [3 ,4 ]
机构
[1] Natl Cheng Kung Univ Hosp, Natl Cheng Kung Univ, Coll Med, Dept Orthoped Surg, Tainan, Taiwan
[2] Natl Cheng Kung Univ, Coll Engn, Dept Biomed Engn, Tainan, Taiwan
[3] Kaohsiung Vet Gen Hosp, Dept Orthoped Surg, Kaohsiung, Taiwan
[4] Meiho Univ, Dept Nursing, Pingtong, Taiwan
关键词
knee; meniscus root; pull-out repair; root tear; slip-knot; AVULSION; STRENGTH; LESIONS; TEAR;
D O I
10.1002/jeo2.70020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To compare the biomechanical properties of the slip-knot technique with three other transtibial pullout suture repair constructs for meniscal root tears. Method Thirty-two fresh-frozen cadaveric menisci were randomly allocated to four meniscus-suture fixation constructs: Two simple-sutures (TSS), two slip-knot (TSK) sutures, two cinch-loop (TCL) sutures, and two modified Mason-Allen (TMMA) sutures. Cyclic loading from 5 to 20 N was conducted for 1000 cycles at 0.5 Hz, and then loaded to failure at 0.5 mm/s. Parametric data (displacement during cyclic loading, ultimate load, yield load, and displacement at failure) were analysed using a one-way analysis of variance (ANOVA), whereas nonparametric data (stiffness) were analysed using the Kruskal-Wallis test. Results After 1000 cycles, the TCL construct significantly displaced the most (mean +/- SD, 6.78 +/- 1.32 mm; p < 0.001), followed by the TMMA (2.83 +/- 0.90 mm), TSK (2.33 +/- 0.57 mm), and TSS (2.03 +/- 0.62 mm) groups. On ultimate failure load, there was no significant difference between the TSK group (123.48 +/- 27.24 N, p > 0.05) and the other three groups (TSS, 94.65 +/- 25.33 N; TMMA, 168.38 +/- 23.24 N; TCL, 170.54 +/- 57.32 N); however, it exhibited the least displacement (5.53 +/- 1.25 mm) which was significantly shorter than those of the TCL (11.82 +/- 4.25 mm, p < 0.001) and TMMA (9.53 +/- 2.18 mm, p = 0.03) constructs. No significant difference in stiffness was observed among the four meniscus-suture constructs. Conclusion The slip-knot technique has proven to be a simple, yet robust and stable meniscal root fixation option; moreover, it exhibited superiority over the more complex modified Mason-Allen suture construct in resisting displacement at the ultimate failure load. Level of Evidence Not applicable.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Biomechanical Evaluation of Different Suture Techniques for Arthroscopic Transtibial Pull-out Repair of Posterior Medial Meniscus Root Tears
    Feucht, Matthias J.
    Grande, Eduardo
    Brunhuber, Johannes
    Burgkart, Rainer
    Imhoff, Andreas B.
    Braun, Sepp
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (12): : 2784 - 2790
  • [2] Different Suture Materials for Arthroscopic Transtibial Pull-out Repair of Medial Meniscal Posterior Root Tears A Human Biomechanical Study
    Nakama, Gilberto Y.
    Aman, Zachary S.
    Storaci, Hunter W.
    Kuczmarski, Alexander S.
    Krob, Joseph J.
    Strauss, Marc J.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2019, 7 (09)
  • [3] Biomechanical evaluation of different suture materials for arthroscopic transtibial pull-out repair of posterior meniscus root tears
    Feucht, Matthias J.
    Grande, Eduardo
    Brunhuber, Johannes
    Rosenstiel, Nikolaus
    Burgkart, Rainer
    Imhoff, Andreas B.
    Braun, Sepp
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (01) : 132 - 139
  • [4] Biomechanical evaluation of different suture materials for arthroscopic transtibial pull-out repair of posterior meniscus root tears
    Matthias J. Feucht
    Eduardo Grande
    Johannes Brunhuber
    Nikolaus Rosenstiel
    Rainer Burgkart
    Andreas B. Imhoff
    Sepp Braun
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 132 - 139
  • [5] Biomechanical comparison of four tibial fixation techniques for meniscal root sutures in posterior medial meniscus root repair: A porcine study
    Wu, Shen-Han
    Yeh, Tsu-Te
    Hsu, Wei-Chun
    Wu, Alexander Th
    Li, Guoan
    Chen, Chih-Hwa
    Lee, Chian-Her
    Wu, Jia-Lin
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 24 : 144 - 149
  • [6] Three single loops enhance the biomechanical behavior of the transtibial pull-out technique for posterior meniscal root repair
    Lawrence Camarda
    Giuseppe Pitarresi
    Michele Lauria
    Federico Fazzari
    Michele D’Arienzo
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 1301 - 1306
  • [7] Three single loops enhance the biomechanical behavior of the transtibial pull-out technique for posterior meniscal root repair
    Camarda, Lawrence
    Pitarresi, Giuseppe
    Lauria, Michele
    Fazzari, Federico
    D'Arienzo, Michele
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (09) : 1301 - 1306
  • [8] Biomechanical Comparison Between Suture Anchor and Transtibial Pull-out Repair for Posterior Medial Meniscus Root Tears
    Feucht, Matthias J.
    Grande, Eduardo
    Brunhuber, Johannes
    Rosenstiel, Nikolaus
    Burgkart, Rainer
    Imhoff, Andreas B.
    Braun, Sepp
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (01): : 187 - 193
  • [9] A biomechanical study of four different meniscal repair systems, comparing pull-out strengths and gapping under cyclic loading
    I. McDermott
    S. Richards
    P. Hallam
    S. Tavares
    J. Lavelle
    A. Amis
    Knee Surgery, Sports Traumatology, Arthroscopy, 2003, 11 : 23 - 29
  • [10] A biomechanical study of four different meniscal repair systems, comparing pull-out strengths and gapping under cyclic loading
    McDermott, ID
    Richards, SW
    Hallam, P
    Tavares, S
    Lavelle, JR
    Amis, AA
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2003, 11 (01) : 23 - 29