Inflammation activity affects liver stiffness measurement by magnetic resonance elastography in MASLD

被引:0
|
作者
Wei, Xiaodie [1 ]
Qi, Shi [2 ]
Wei, Xinhuan [1 ]
Qiu, Lixia [1 ]
Du, Xiaofei [1 ]
Liu, Yali [1 ]
Xu, Hangfei [1 ]
Zhao, Jinhan [1 ]
Chen, Sitong [1 ]
Zhang, Jing [1 ]
机构
[1] Capital Med Univ, Beijing Youan Hosp, Dept Hepatol, Unit 3, Beijing 100069, Peoples R China
[2] Capital Med Univ, Beijing Youan Hosp, Dept Radiol, Beijing, Peoples R China
关键词
Magnetic resonance elastography; Liver fibrosis; Liver inflammation; Metabolic dysfunction-associated steatotic; liver disease; MR ELASTOGRAPHY; FIBROSIS; PERFORMANCE;
D O I
10.1016/j.dld.2024.04.031
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Magnetic resonance elastography (MRE) is recognized as the most precise imaging technology for assessing liver fibrosis in individuals with metabolic dysfunction-associated steatotic liver disease (MASLD). We aimed to investigate the clinical factors and pathological characteristics that may impact LSM in MASLD patients. Methods: This cross-sectional study recruited 124 patients who concurrently performed MRE, MRI-PDFF, and biopsy-proven MASLD. Linear regression models, Spearman's correlation, and subgroup analysis were employed to identify the variables affecting LSM. Results: The AUROC (95 % CI) of MRE for diagnosing fibrosis stage >= 1, 2, 3, and 4 was 0.80 (0.70-0.90), 0.76 (0.66-0.85), 0.92 (0.86-0.99), and 0.99 (0.99-1.0 0), with corresponding cutoffs of 2.56, 2.88, 3.35, and 4.76 kPa, respectively. Multivariate analyses revealed that AST was the only independent clinical variable significantly correlated with LSM. Furthermore, LSM exhibited a notable association with the grade of lobular inflammation and hepatocellular ballooning. Subgroup analysis showed that when AST >= 2 ULN or inflammation grade >= 2, LSM of patients with early fibrosis stages showed a slight but significant increase. Conclusion: MRE demonstrates significant diagnostic accuracy in predicting liver fibrosis stages for MASLD patients, especially for advanced liver fibrosis and cirrhosis. However, elevated AST and the severity of liver inflammation may impact its accuracy in staging early liver fibrosis.
引用
收藏
页码:1715 / 1720
页数:6
相关论文
共 50 条
  • [1] Liver stiffness measurement by magnetic resonance elastography is not affected by hepatic steatosis
    Jie Chen
    Alina M. Allen
    Terry M. Therneau
    Jun Chen
    Jiahui Li
    Safa Hoodeshenas
    Jingbiao Chen
    Xin Lu
    Zheng Zhu
    Sudhakar K. Venkatesh
    Bin Song
    Richard L. Ehman
    Meng Yin
    European Radiology, 2022, 32 : 950 - 958
  • [2] Liver stiffness measurement by magnetic resonance elastography is not affected by hepatic steatosis
    Chen, Jie
    Allen, Alina M.
    Therneau, Terry M.
    Chen, Jun
    Li, Jiahui
    Hoodeshenas, Safa
    Chen, Jingbiao
    Lu, Xin
    Zhu, Zheng
    Venkatesh, Sudhakar K.
    Song, Bin
    Ehman, Richard L.
    Yin, Meng
    EUROPEAN RADIOLOGY, 2022, 32 (02) : 950 - 958
  • [3] Change in serial liver stiffness measurement by magnetic resonance elastography and outcomes in NAFLD
    Gidener, Tolga
    Dierkhising, Ross A.
    Mara, Kristin C.
    Therneau, Terry M.
    Venkatesh, Sudhakar K.
    Ehman, Richard L.
    Yin, Meng
    Allen, Alina M.
    HEPATOLOGY, 2023, 77 (01) : 268 - 274
  • [4] Measurement of the liver stiffness with two imaging techniques: magnetic resonance elastography and Fibroscan
    Bensamoun, S.
    Wang, L.
    Robert, L.
    Charleux, F.
    Latrive, J. P.
    Tho, M. C. Ho Ba
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2008, 11 : 31 - 32
  • [5] The role of magnetic resonance elastography in liver stiffness evaluation
    Mannelli, Lorenzo
    Monti, Serena
    Ogurtsov, Pavel
    POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2019, 129 (05): : 301 - 302
  • [6] Automated liver stiffness measurements with magnetic resonance elastography
    Dzyubak, Bogdan
    Glaser, Kevin
    Yin, Meng
    Talwalkar, Jayant
    Chen, Jun
    Manduca, Armando
    Ehman, Richard L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (02) : 371 - 379
  • [7] Liver stiffness measurement in patients with nodular regenerative hyperplasia undergoing magnetic resonance elastography
    Cannella, Roberto
    Minervini, Marta I.
    Rachakonda, Vikrant
    Bollino, Gideon
    Furlan, Alessandro
    ABDOMINAL RADIOLOGY, 2020, 45 (02) : 373 - 383
  • [8] Liver stiffness measurement in patients with nodular regenerative hyperplasia undergoing magnetic resonance elastography
    Roberto Cannella
    Marta I. Minervini
    Vikrant Rachakonda
    Gideon Bollino
    Alessandro Furlan
    Abdominal Radiology, 2020, 45 : 373 - 383
  • [9] Measurement of Liver Stiffness With Two Imaging Techniques: Magnetic Resonance Elastography and Ultrasound Elastometry
    Bensamoun, Sabine F.
    Wang, Lu
    Robert, Ludovic
    Charleux, Fabrice
    Latrive, Jean-Paul
    Tho, Marie-Christine Ho Ba
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (05) : 1287 - 1292
  • [10] LIVER STIFFNESS MEASUREMENT BY MAGNETIC RESONANCE ELASTOGRAPHY PREDICTS FUTURE DEVELOPMENT OF CIRRHOSIS AND DECOMPENSATION
    Gidener, Tolga
    Ahmed, Omar T.
    Larson, Joseph
    Therneau, Terry M.
    Dzyubak, Bogdan
    Venkatesh, Sudhakar K.
    Ehman, Richard
    Yin, Meng
    Allen, Alina M.
    HEPATOLOGY, 2019, 70 : 1239A - 1240A