All-Fiber Michelson Interferometer for Heart Rate and Breath Monitoring

被引:0
|
作者
Shao, Min [1 ]
Yuan, Yubo [1 ]
Liu, Yinggang [1 ]
Fu, Haiwei [1 ]
Qiao, Xueguang [2 ]
机构
[1] Xian Shiyou Univ, Sch Sci, Key Lab Photoelect Oil Gas Logging & Detecting, Minist Educ, Xian 710065, Peoples R China
[2] Northwest Univ, Sch Sci, Xian, Peoples R China
基金
中国国家自然科学基金;
关键词
Optical fiber sensors; Sensors; Optical fibers; Monitoring; Biomedical monitoring; Sensitivity; Heart beat; All-fiber Michelson interferometer (MI); breath; heart rate (HR); optical fiber sensor; WEARABLE SYSTEM; FBG;
D O I
10.1109/JSEN.2024.3415073
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Heart rate (HR) and breath monitoring technology based on optical fiber sensors have been widely developed in the field of healthcare due to their high sensitivity, flexibility, adaptability, and lightweight, however exploring exquisite and robust sensors and enhancing integration remain challenges. In this article, an all-fiber Michelson interferometer (MI) for HR and breath monitoring is presented. A fiber cylinder and a fiber sphere are employed in the configuration of the sensor, which not only improves its perception of human physiological signals but also holds robustness and compactness. Microbending significantly modulates the mode interference intensity, providing accurate detection of vital signs. The experimental test demonstrates that the sensor could detect human HR and breath signals and identify these physiological signals under different modes (static, posture, and dynamic). Moreover, the influence of wearing position on physiological detection is investigated, thereby expanding its wearable potential applications. The work is expected to offer a practical strategy for using optical fiber sensors in healthcare applications.
引用
下载
收藏
页码:23909 / 23917
页数:9
相关论文
共 50 条
  • [2] All-fiber, all-optical modulator based on Michelson interferometer structure
    Zhu, M.
    Zhang, M.
    Wu, Q.
    Zheng, Z.
    2020 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2020,
  • [3] ALL-FIBER MICHELSON THERMOMETER
    CORKE, M
    KERSEY, AD
    JACKSON, DA
    JONES, JDC
    ELECTRONICS LETTERS, 1983, 19 (13) : 471 - 473
  • [5] HIGH-SENSITIVE ALL-FIBER MICHELSON INTERFEROMETER BY USE OF DIFFERENTIAL OUTPUT CONFIGURATION
    IMAI, M
    OHASHI, T
    OHTSUKA, Y
    OPTICS COMMUNICATIONS, 1981, 39 (1-2) : 7 - 10
  • [6] Ultralow Noise Microwave Generation based on All-Fiber Michelson Interferometer and Sagnac Loop
    Kwon, Dohyeon
    Wei, Juan
    Pan, Shilong
    Kim, Jungwon
    2018 INTERNATIONAL TOPICAL MEETING ON MICROWAVE PHOTONICS (MWP), 2018,
  • [7] All-fiber Michelson-Gires-Tournois interferometer as multi-passband filter
    Shu, XW
    Sugden, K
    Bennion, I
    2004 1ST IEEE LIGHTWAVE TECHNOLOGIES IN INSTRUMENTATION AND MEASUREMENT CONFERENCE, 2004, : 144 - 147
  • [8] An efficient all-fiber interleaving filter using fiber Gires-Tournois etalons on a Michelson interferometer
    Wang, Qijie
    Zhang, Ying
    Soh, Yeng Chai
    2006 OPTICAL FIBER COMMUNICATION CONFERENCE/NATIONAL FIBER OPTIC ENGINEERS CONFERENCE, VOLS 1-6, 2006, : 729 - +
  • [9] Sensitivity tailoring of an all-fiber bend sensor based on a dual-core fiber unbalanced Michelson interferometer
    Budnicki, Dawid
    Parola, Itxaso
    Szostkiewicz, Lukasz
    Markiewicz, Krzysztof
    Wilczynski, Krzysztof
    Kuklinska, Malgorzata
    Mergo, Pawel
    Napierala, Marek
    Nasilowski, Tomasz
    OPTICS EXPRESS, 2021, 29 (24): : 39137 - 39149
  • [10] All-fiber flat-top comb filter based on a Mach-Zehnder interferometer cascading a Michelson interferometer
    Wang, Hongchu
    Wu, Xiaowei
    Meng, Hongyun
    OPTIK, 2015, 126 (19): : 1806 - 1808