A unique electro-contact-free sensing for illegal drug methamphetamine determination by electrochemiluminescence based on wireless power transmission technology

被引:0
|
作者
Takahashi, Fumiki [1 ]
Kaneko, Mayu [1 ]
Goshima, Buntaro [1 ]
Harayama, Yuta [2 ]
Kobayashi, Kanya [2 ]
Nakamura, Katsuya [3 ]
Hamamoto, Satoru [4 ]
Oura, Masaki [4 ]
Seto, Yasuo [4 ]
Tatsumi, Hirosuke [1 ]
Jin, Jiye [1 ]
机构
[1] Shinshu Univ, Fac Sci, Dept Chem, Matsumoto, Nagano 3908621, Japan
[2] Shinshu Univ, Sch Med, Dept Legal Med, Matsumoto, Nagano 3908621, Japan
[3] Shinshu Univ Hosp, Ctr Med Genet, Matsumoto, Nagano 3908621, Japan
[4] RIKEN SPring 8 Ctr, Koto, Hyogo 6795148, Japan
来源
关键词
Wireless power transfer; Electrochemiluminescence; Methamphetamine; Sensor; On-site analysis; Urine; AMPHETAMINE-TYPE STIMULANTS; REDUCTION; SENSOR;
D O I
10.1016/j.snb.2024.136327
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The wireless power transfer (WPT) technique is a unique safe electric power supply system. In this study, we designed a simple analytical system that combines electrochemiluminescence (ECL) measurement with WPT for illegal stimulant methamphetamine (MA) detection. The WPT-ECL system, which consists of a commercially available inexpensive driving coil and a commonly available enameled wire, was used to screen MA with an easy procedure. The prototype WPT-ECL measurement system observed a clear ECL response by incorporating an inexpensive rectifying diode, and MA was determined in the range to 500 mu M with the detection limit of ca. 15 mu M (S/N =3). The MA detection protocol under WPT-ECL measurement was characterized; it was expected to be a simple and cost-effective analytical technique without complex circuitry, such as full-wave rectification. The proposed WPT-ECL system was applied to an actual urine sample. MA addition and recovery experiments on three volunteer urine samples showed good reproducibility with an RSD of less than 6 %, resulting in good agreement with the LC-MS results. The WPT-ECL system was expected to enable non-specialist investigators to simple detection procedures of MA, with the aim of practical application to forensic toxicology analytical scenes.
引用
收藏
页数:9
相关论文
共 1 条
  • [1] Wireless Transmission System for Motion Sensing Game Controller based on Low Power Bluetooth Technology
    Tian, Junfei
    Liu, Jingen
    Liang, Shengyun
    Ning, Yunkun
    Li, Huiqi
    Zhao, Guoru
    PROCEEDINGS OF 2016 IEEE 13TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP 2016), 2016, : 1319 - 1323