Simultaneous Detection of Multiple Respiratory Pathogens Using an Integrated Microfluidic Chip

被引:2
|
作者
Li, Jun [1 ]
Gao, Zehang [2 ]
Jia, Chunping [2 ]
Cai, Gaozhe [3 ]
Feng, Shilun [2 ]
Wu, Man [2 ]
Zhao, Hui [2 ]
Yu, Juan [4 ]
Bao, Fang [4 ]
Cong, Hui [4 ]
Bian, Xiaojun [1 ]
Zhao, Jianlong [2 ,5 ]
机构
[1] Shanghai Ocean Univ, Coll Food Sci & Technol, Int Res Ctr Food & Hlth, Shanghai 201306, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Lab Transducer Technol, Shanghai 200050, Peoples R China
[3] Shanghai Univ, Sch Microelect, Shanghai 200444, Peoples R China
[4] Nantong Univ, Affiliated Hosp, Nantong 226001, Peoples R China
[5] Univ Chinese Acad Sci, Ctr Mat Sci & Optoelect Engn, Beijing 100049, Peoples R China
关键词
REAL-TIME PCR; DIAGNOSIS;
D O I
10.1021/acs.analchem.4c00990
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Respiratory pathogens pose significant challenges to public health, demanding efficient diagnostic methods. This study presents an integrated microfluidic chip for the simultaneous detection of multiple respiratory pathogens. The chip integrates magnetic bead-based nucleic acid extraction and purification, acoustic streaming-driven mixing, liquid equalization, and multiplex PCR amplification with in situ fluorescence detection. Nucleic acid extraction takes only 12 min, yielding results comparable to commercial kits. Efficient mixing of magnetic beads is achieved through a combination of designed micropillars and bubble-trapping array structures. The micropillars maintain the aqueous phase in the mixing chamber, while the bubble-trapping arrays enable stable formation of bubbles, serving as a micromixer under the acoustic field. To prevent cross-contamination, an oil-encapsulated water droplet system is incorporated throughout nucleic acid extraction and PCR amplification. This assay displays remarkable multiplex analysis capability on a single chip, enabling the simultaneous detection of 12 common respiratory pathogens with a low detection limit of 10 copies/mu L. Moreover, this method demonstrates excellent practical applicability in clinical nasal samples. Compared to many microfluidic chip-based molecular biology methods, the assay exhibits comparable or superior multipathogen analysis capability, sensitivity, and speed, completing the sample-to-answer process in approximately 70 min. This integrated microfluidic device offers a promising multiplex molecular diagnosis platform for on-site simultaneous detection of multiple pathogens.
引用
收藏
页码:13768 / 13776
页数:9
相关论文
共 50 条
  • [1] A polymeric microfluidic device integrated with nanoporous alumina membranes for simultaneous detection of multiple foodborne pathogens
    Tian, Feng
    Lyu, Jing
    Shi, Jingyu
    Tan, Fei
    Yang, Mo
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 225 : 312 - 318
  • [2] An integrated microfluidic device for the simultaneous detection of multiple antibiotics
    Wang, Xiaorui
    Xing, Gaowa
    Li, Nan
    Xie, Yaoshuang
    Lin, Ling
    CHINESE CHEMICAL LETTERS, 2023, 34 (08)
  • [3] An integrated microfluidic device for the simultaneous detection of multiple antibiotics
    Xiaorui Wang
    Gaowa Xing
    Nan Li
    Yaoshuang Xie
    Ling Lin
    ChineseChemicalLetters, 2023, 34 (08) : 313 - 316
  • [4] Real-time PCR-based microfluidic array chip for simultaneous detection of multiple waterborne pathogens
    Ramalingam, Naveen
    Rui, Zhang
    Liu, Hao-Bing
    Dai, Chang-Chun
    Kaushik, Rajni
    Ratnaharika, Bandi
    Gong, Hai-Qing
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (01): : 543 - 552
  • [5] An integrated microfluidic chip for nucleic acid extraction and continued cdPCR detection of pathogens
    Huang, Yaru
    Gao, Zehang
    Ma, Cong
    Sun, Yimeng
    Huang, Yuhang
    Jia, Chunping
    Zhao, Jianlong
    Feng, Shilun
    ANALYST, 2023, 148 (12) : 2758 - 2766
  • [6] A microfluidic chip-based multivalent DNA walker amplification biosensor for the simultaneous detection of multiple food-borne pathogens
    Xu, Zhenli
    Wang, Jiaqi
    Jia, Zhijian
    Wu, Yong-Xiang
    Gan, Ning
    Yu, Shaoning
    ANALYST, 2023, 148 (05) : 1093 - 1101
  • [7] Integrated and finger-actuated microfluidic chip for point-of-care testing of multiple pathogens
    Chen, Peng
    Chen, Chen
    Su, Huiying
    Zhou, Mengfan
    Li, Shunji
    Du, Wei
    Feng, Xiaojun
    Liu, Bi-Feng
    TALANTA, 2021, 224
  • [8] Microfluidic chip coupled with optical biosensors for simultaneous detection of multiple analytes: A review
    Liao, Zerong
    Zhang, Yang
    Li, Yongrui
    Miao, Yunfei
    Gao, Shimeng
    Lin, Fankai
    Deng, Yulin
    Geng, Lina
    BIOSENSORS & BIOELECTRONICS, 2019, 126 (697-706): : 697 - 706
  • [9] An integrated wearable microfluidic biosensor for simultaneous detection of multiple biomarkers in sweat
    Zhang, Yong
    Zeng, Xin
    Wang, Cuncun
    Liu, Yiyi
    Jin, Changpeng
    Chen, Jian
    Hou, Jingzhou
    Huo, Danqun
    Hou, Changjun
    TALANTA, 2025, 285
  • [10] Detection of pathogens in foods using microfluidic "lab-on-chip": A mini review
    Lonchamps, Pierre-Luc
    He, Yihan
    Wang, Kaidi
    Lu, Xiaonan
    JOURNAL OF AGRICULTURE AND FOOD RESEARCH, 2022, 10