Comparison of structural, mechanical, and histochemical characteristics of L-PRF and T-PRF membranes using different centrifugation protocols - An ex-vivo observational study

被引:0
|
作者
Pasupuleti, Mohan Kumar [1 ]
Haripriya, N. [1 ]
Penmetsa, Gautami S. [1 ]
Pasupuleti, Swetha [2 ]
Gottumukkala, Sruthima N. V. S. [1 ]
Ramesh, K. S. V. [1 ]
Vivek, B. [1 ]
机构
[1] Vishnu Dent Coll, Dept Periodont & Implantol, Bhimavaram, Andhra Pradesh, India
[2] Vishnu Dent Coll, Dept Oral & Maxillofacial Pathol, Bhimavaram, Andhra Pradesh, India
关键词
Centrifugation; Ex-vivo; Platelet-rich fibrin; Regeneration; Hemoderivatives; PLATELET-RICH FIBRIN;
D O I
10.1016/j.ajoms.2023.12.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Many investigators are looking into the possibility of using platelet-rich. hemoderivatives as a source of the protein structures and cytokines necessary for. periodontal healing of wounds. The objective of the study was to evaluate and. compare the structural, mechanical, and histochemical characteristics of L-PRF and TPRF. membranes prepared by using three different centrifugation protocols. Methods: Thirty participants around the ages of 20 and 35 who were in good overall. health had their antecubital veins pricked for ten milliliters of the blood. Venous blood. was centrifuged immediately after collection in silica- coated glass tubes and titaniumcoated. tubes utilizing the APRF machine. The mechanical properties of PRF. membranes (n = 30) for L-PRF and T-PRF each protocol) were assessed using a. desktop universal testing machine. Results: The forces around 700 g (3200 rpm, 15 min) yielded a PRF membrane with. desirable mechanodegradation characteristics for its clinical application. Histochemical examination revealed mixed inflammatory infiltrate with predominantly. platelets followed by lymphocytes, neutrophils& & monocytes in T-PRF. Whereas, in. LPRF thin strands of mixed inflammatory infiltrate predominantly neutrophils &. monocytes are seen in the connective tissue stroma. Conclusion: This study demonstrated that centrifugation speed, force, and time. influenced the structural, and mechanical properties of PRF membranes prepared with. various protocols. This is the first study to reveal the marked impact of glass and. titanium-reinforced centrifugation tubes on the final production of PRF. It was further. found that a significant difference was observed between L-PRF and T-PRF at. 3200 rpm and 2700 rpm protocols.
引用
收藏
页码:507 / 511
页数:5
相关论文
共 3 条
  • [1] Mechanical, chemical, structural analysis and comparative release of PDGF-AA from L-PRF, A-PRF and T-PRF - an in vitro study
    Shravanthy Ravi
    Muthukumar Santhanakrishnan
    Biomaterials Research, 24
  • [2] Mechanical, chemical, structural analysis and comparative release of PDGF-AA from L-PRF, A-PRF and T-PRF - an in vitro study
    Ravi, Shravanthy
    Santhanakrishnan, Muthukumar
    BIOMATERIALS RESEARCH, 2020, 24 (01)
  • [3] Tensile Strength Essay Comparing Three Different Platelet-Rich Fibrin Membranes (L-PRF, A-PRF, and A-PRF plus ): A Mechanical and Structural In Vitro Evaluation
    Simoes-Pedro, Mara
    Troia, Pedro Maria B. P. S.
    Malta dos Santos, Nuno Bernardo
    Completo, Antonio M. G.
    Castilho, Rogerio Moraes
    Fernandes, Gustavo Vicentis de Oliveira
    POLYMERS, 2022, 14 (07)