Multi-camera Coordinate Calibration and Accuracy Evaluation for Robot Control

被引:1
|
作者
Nonaka, Masahiro [1 ]
Noborio, Hiroshi [1 ,2 ,3 ]
Onishi, Katsuhiko [1 ,2 ,3 ]
Tachibana, Katsunori [1 ,2 ,3 ]
Watanabe, Kaoru [2 ]
Mizushino, Kiminori [3 ]
机构
[1] Kansai Med Univ, Hirakata, Osaka 5731010, Japan
[2] Osaka Electrocommun Univ, Shijo Nawate, Osaka 5750063, Japan
[3] Embedded Wings Co, Mino, Osaka 5620015, Japan
关键词
Neurosurgery; Navigation system; Intel RealSense Depth Camera D435; Organ deformation and movement; Brain shift; AUGMENTED REALITY;
D O I
10.1007/978-3-030-22643-5_40
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
In this study, our goal is to create a surgical navigation system that takes stable measurements of a surgical area using RGB/depth cameras without obstructions, such as the surgeon's head or hands. We mounted three cutting-edge D435 Intel RealSense Depth Cameras onto a ring and photographed the surgical area from three directions. We also installed a robotic mechanical system that can move the camera ring up and down so that the surgery can proceed smoothly. First, we calibrated the coordinate systems so that the coordinate systems of the three cameras (three-dimensional XYZ coordinate system) align and their Y-axis (vertical axis) aligns with the moving axis of the robot slider. Next, we captured an ArUco marker with each camera and visualized its position within the camera coordinate system. After verifying that the initial positions of the ArUco marker captured by the three cameras match, we moved the robot slider up by 50 mm thrice and investigated the degree of change in the measured position of the ArUco marker measured by the three cameras. The results show that as the ArUco marker moves farther away, the extent of error in the measured position of the ArUco marker increases. Additionally, the measured position of all the ArUco markers varied owing to the digital pixel error in the two-dimensional images (the pixel in which the ArUco marker is visible moves between neighboring pixels). Future work includes checking that the calibration pattern and ArUco marker are parallel to the camera ring and perpendicular to the robot slider using a level instrument; packing the calibration pattern and ArUco marker horizontally with vinyl; and implementing a moving average in the program to reduce pixel digital error in the calculations to sub-pixel level.
引用
收藏
页码:506 / 523
页数:18
相关论文
共 50 条
  • [1] Calibration accuracy evaluation method for multi-camera measurement systems
    Yuan, Fang
    Xia, Zhiyuan
    Tang, Baijian
    Yin, Zhuoyi
    Shao, Xinxing
    He, Xiaoyuan
    MEASUREMENT, 2025, 242
  • [2] Calibration of Multi-Camera Systems
    Dondo, Diego Gonzalez
    Trasobares, Fernando
    Yoaquino, Leandro
    Padilla, Julian
    Redolfi, Javier
    2015 XVI WORKSHOP ON INFORMATION PROCESSING AND CONTROL (RPIC), 2015,
  • [3] Effective Calibration and Evaluation of Multi-Camera Robotic Head
    Kocmanova, Petra
    Zalud, Ludek
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2015, 6 (10) : 143 - 152
  • [4] CALIBRATION OF A MULTI-CAMERA ROVER
    Brunn, A.
    Meyer, Th.
    XXIII ISPRS Congress, Commission V, 2016, 41 (B5): : 445 - 452
  • [5] Understanding Control Frames in Multi-Camera Robot Telemanipulation
    Praveena, Pragathi
    Molina, Luis
    Wang, Yeping
    Senft, Emmanuel
    Mutlu, Bilge
    Gleicher, Michael
    PROCEEDINGS OF THE 2022 17TH ACM/IEEE INTERNATIONAL CONFERENCE ON HUMAN-ROBOT INTERACTION (HRI '22), 2022, : 432 - 440
  • [6] Multi-camera System Calibration of Indoor Mobile Robot Based on SLAM
    Zhu, Ying
    Wu, Yuxin
    Zhang, Yawan
    Qu, Fukang
    2021 3RD INTERNATIONAL CONFERENCE ON MACHINE LEARNING, BIG DATA AND BUSINESS INTELLIGENCE (MLBDBI 2021), 2021, : 240 - 244
  • [7] Efficient, Precise, and Convenient Calibration of Multi-camera Systems by Robot Automation
    Werner, Tobias
    Harrer, David
    Henrich, Dominik
    ADVANCES IN SERVICE AND INDUSTRIAL ROBOTICS, RAAD 2018, 2019, 67 : 669 - 677
  • [8] Increasing the accuracy of untaught robot positions by means of a multi-camera system
    Boochs, Frank
    Schuetze, Rainer
    Simon, Camille
    Marzanit, Franck
    Wirth, Holger
    Meier, Juergen
    2010 INTERNATIONAL CONFERENCE ON INDOOR POSITIONING AND INDOOR NAVIGATION, 2010,
  • [9] Complete calibration of a multi-camera network
    Baker, P
    Aloimonos, Y
    IEEE WORKSHOP ON OMNIDIRECTIONAL VISION, PROCEEDINGS, 2000, : 134 - 141
  • [10] CALIBRATION OF MULTI-CAMERA PHOTOGRAMMETRIC SYSTEMS
    Detchev, I.
    Mazaheri, M.
    Rondeel, S.
    Habib, A.
    ISPRS TECHNICAL COMMISSION I SYMPOSIUM, 2014, 40-1 : 101 - 108