Sample-to-answer centrifugal microfluidic droplet PCR platform for quantitation of viral load

被引:0
|
作者
Malic, Lidija [1 ,2 ,3 ,4 ]
Clime, Liviu [1 ,2 ,3 ]
Moon, Byeong-Ui [1 ,2 ,3 ]
Nassif, Christina [1 ,2 ,3 ]
Da Fonte, Dillon [1 ,2 ,3 ]
Brassard, Daniel [1 ,2 ,3 ]
Lukic, Ljuboje [1 ,2 ,3 ]
Geissler, Matthias [1 ,2 ,3 ]
Morton, Keith [1 ,2 ,3 ]
Charlebois, Denis [5 ]
Veres, Teodor [1 ,2 ,3 ,6 ]
机构
[1] Natl Res Council Canada NRC, Life Sci Div, 75 Mortagne Blvd, Boucherville, PQ J4B 6Y4, Canada
[2] Sunnybrook Res Inst, Ctr Res & Applicat Fluid Technol CRAFT NRC, Toronto, ON, Canada
[3] Univ Toronto, Toronto, ON, Canada
[4] McGill Univ, Dept Biomed Engn, 775 Rue Univ,Suite 316, Montreal, PQ H3A 2B4, Canada
[5] Canadian Space Agcy, 6767 Route Aeroport, St Hubert, PQ J3Y 8Y9, Canada
[6] Univ Toronto, Dept Mech & Ind Engn, 5 Kings Coll Rd, Toronto, ON M5S 3G8, Canada
关键词
DIGITAL PCR; QUANTIFICATION; SYSTEM;
D O I
10.1039/d4lc00533c
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Droplet digital polymerase chain reaction (ddPCR) stands out as a highly sensitive diagnostic technique that is gaining traction in infectious disease diagnostics due to its ability to quantitate very low numbers of viral gene copies. By partitioning the sample into thousands of droplets, ddPCR enables precise and absolute quantification without relying on a standard curve. However, current ddPCR systems often exhibit relatively low levels of integration, and the analytical process remains dependent on elaborate workflows for up-front sample preparation. Here, we introduce a fully-integrated system seamlessly combining viral lysis, RNA extraction, emulsification, reverse transcription (RT) ddPCR, and fluorescence readout in a sample-to-answer format. The system comprises a disposable microfluidic cartridge housing buffers and reagents required for the assay, and a centrifugal platform that allows for pneumatic actuation of liquids during rotation, enabling automation of the workflow. Highly monodisperse droplets (similar to 50 mu m in diameter) are produced using centrifugal step emulsification and automatically transferred to an integrated heating module for target amplification. The platform is equipped with a miniature fluorescence imaging system enabling on-chip read-out of droplets after RT-ddPCR. We demonstrate sample-to-answer detection of SARS-CoV-2 N and E genes, along with RNase P endogenous reference, using hydrolysis probes and multiplexed amplification within single droplets for concentrations as low as 0.1 copy per mu L. We also tested 14 nasopharyngeal swab specimens from patients and were able to distinguish positive and negative SARS-CoV-2 samples with 100% accuracy, surpassing results obtained by conventional real-time amplification. Fully automated sample-to-answer ddPCR for virus quantification is implemented on a centrifugal platform with active pneumatic pumping comprising wireless heaters and miniaturized fluorescence imaging system.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Sample-to-Answer Droplet Magnetofluidic Platform for Point-of-Care Hepatitis C Viral Load Quantitation
    Shin, Dong Jin
    Trick, Alexander Y.
    Hsieh, Yu-Hsiang
    Thomas, David L.
    Wang, Tza-Huei
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [2] Sample-to-Answer Droplet Magnetofluidic Platform for Point-of-Care Hepatitis C Viral Load Quantitation
    Dong Jin Shin
    Alexander Y. Trick
    Yu-Hsiang Hsieh
    David L. Thomas
    Tza-Huei Wang
    [J]. Scientific Reports, 8
  • [3] Centrifugal microfluidic system for colorimetric sample-to-answer detection of viral pathogens
    Geissler, Matthias
    Brassard, Daniel
    Adam, Nadine
    Nasheri, Neda
    Pilar, Ana Victoria C.
    Tapp, Kyle
    Clime, Liviu
    Miville-Godin, Caroline
    Mounier, Maxence
    Nassif, Christina
    Lukic, Ljuboje
    Malic, Lidija
    Corneau, Nathalie
    Veres, Teodor
    [J]. LAB ON A CHIP, 2024, 24 (04) : 668 - 679
  • [4] A fully automated centrifugal microfluidic system for sample-to-answer viral nucleic acid testing
    Tian, Fei
    Liu, Chao
    Deng, Jinqi
    Han, Ziwei
    Zhang, Lu
    Chen, Qinghua
    Sun, Jiashu
    [J]. SCIENCE CHINA-CHEMISTRY, 2020, 63 (10) : 1498 - 1506
  • [5] A fully automated centrifugal microfluidic system for sample-to-answer viral nucleic acid testing
    Fei Tian
    Chao Liu
    Jinqi Deng
    Ziwei Han
    Lu Zhang
    Qinghua Chen
    Jiashu Sun
    [J]. Science China Chemistry, 2020, 63 : 1498 - 1506
  • [6] A fully automated centrifugal microfluidic system for sample-to-answer viral nucleic acid testing
    Fei Tian
    Chao Liu
    Jinqi Deng
    Ziwei Han
    Lu Zhang
    Qinghua Chen
    Jiashu Sun
    [J]. Science China Chemistry, 2020, 63 (10) : 1498 - 1506
  • [7] A sample-to-answer droplet magnetofluidic assay platform for quantitative methylation-specific PCR
    Stark, Alejandro
    Shin, Dong Jin
    Wang, Tza-Huei
    [J]. BIOMEDICAL MICRODEVICES, 2018, 20 (02)
  • [8] A sample-to-answer droplet magnetofluidic assay platform for quantitative methylation-specific PCR
    Alejandro Stark
    Dong Jin Shin
    Tza-Huei Wang
    [J]. Biomedical Microdevices, 2018, 20
  • [9] μPADs on Centrifugal Microfluidic Discs for Rapid Sample-to-Answer Salivary Diagnostics
    Liu, Shixian
    Hou, Yuting
    Li, Zirui
    Yang, Chenyu
    Liu, Guozhen
    [J]. ACS SENSORS, 2023, 8 (09) : 3520 - 3529
  • [10] ELECTROMAGNET-ACTUATED DROPLET PLATFORM FOR SAMPLE-TO-ANSWER GENETIC DETECTION
    Chiou, C. H.
    Shin, D. J.
    Hosmane, S.
    Zhang, Y.
    Wang, T. H.
    [J]. 26TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2013), 2013, : 98 - 101