Intraoperative detection of parathyroid glands using artificial intelligence: optimizing medical image training with data augmentation methods

被引:2
|
作者
Lee, Joon-Hyop [1 ]
Ku, EunKyung [2 ]
Chung, Yoo Seung [3 ]
Kim, Young Jae [4 ]
Kim, Kwang Gi [4 ]
机构
[1] Samsung Med Ctr, Dept Surg, Div Endocrine Surg, 81 Irwon Ro, Seoul, South Korea
[2] Catholic Univ Korea, Dept Digital Media, 43 Jibong Ro, Bucheon 14662, Gyeonggi Do, South Korea
[3] Gachon Univ, Gil Med Ctr, Dept Surg, Div Endocrine Surg,Coll Med, Incheon, South Korea
[4] Gachon Univ, Coll Med, Gil Med Ctr, Dept Biomed Engn, 38-13 Dokjeom Ro 3Beon Gil, Incheon 21565, South Korea
基金
新加坡国家研究基金会;
关键词
Parathyroid gland; Artificial intelligence; Object detection; Data augmentation; Generative adversarial network; QUALITY ASSESSMENT; THYROID-SURGERY; ASSOCIATION; STATEMENT;
D O I
10.1007/s00464-024-11115-z
中图分类号
R61 [外科手术学];
学科分类号
摘要
BackgroundPostoperative hypoparathyroidism is a major complication of thyroidectomy, occurring when the parathyroid glands are inadvertently damaged during surgery. Although intraoperative images are rarely used to train artificial intelligence (AI) because of its complex nature, AI may be trained to intraoperatively detect parathyroid glands using various augmentation methods. The purpose of this study was to train an effective AI model to detect parathyroid glands during thyroidectomy.MethodsVideo clips of the parathyroid gland were collected during thyroid lobectomy procedures. Confirmed parathyroid images were used to train three types of datasets according to augmentation status: baseline, geometric transformation, and generative adversarial network-based image inpainting. The primary outcome was the average precision of the performance of AI in detecting parathyroid glands.Results152 Fine-needle aspiration-confirmed parathyroid gland images were acquired from 150 patients who underwent unilateral lobectomy. The average precision of the AI model in detecting parathyroid glands based on baseline data was 77%. This performance was enhanced by applying both geometric transformation and image inpainting augmentation methods, with the geometric transformation data augmentation dataset showing a higher average precision (79%) than the image inpainting model (78.6%). When this model was subjected to external validation using a completely different thyroidectomy approach, the image inpainting method was more effective (46%) than both the geometric transformation (37%) and baseline (33%) methods.ConclusionThis AI model was found to be an effective and generalizable tool in the intraoperative identification of parathyroid glands during thyroidectomy, especially when aided by appropriate augmentation methods. Additional studies comparing model performance and surgeon identification, however, are needed to assess the true clinical relevance of this AI model.
引用
收藏
页码:5732 / 5745
页数:14
相关论文
共 50 条
  • [1] Development of an algorithm for intraoperative autofluorescence assessment of parathyroid glands in primary hyperparathyroidism using artificial intelligence
    Akbulut, Serkan
    Erten, Ozgun
    Kim, Yoo Seok
    Gokceimam, Mehmet
    Berber, Eren
    SURGERY, 2021, 170 (02) : 454 - 461
  • [2] Artificial Intelligence Methods for Identifying and Localizing Abnormal Parathyroid Glands: A Review Study
    Apostolopoulos, Ioannis D.
    Papandrianos, Nikolaos I.
    Papageorgiou, Elpiniki I.
    Apostolopoulos, Dimitris J.
    MACHINE LEARNING AND KNOWLEDGE EXTRACTION, 2022, 4 (04): : 814 - 826
  • [3] MinimalGAN: diverse medical image synthesis for data augmentation using minimal training data
    Zhang, Yipeng
    Wang, Quan
    Hu, Bingliang
    APPLIED INTELLIGENCE, 2023, 53 (04) : 3899 - 3916
  • [4] MinimalGAN: diverse medical image synthesis for data augmentation using minimal training data
    Yipeng Zhang
    Quan Wang
    Bingliang Hu
    Applied Intelligence, 2023, 53 : 3899 - 3916
  • [5] Intraoperative detection of parathyroid glands by autofluorescence identification using image-based system: report of 15 cases
    Gorobeiko, Maksym
    Dinets, Andrii
    JOURNAL OF MEDICAL CASE REPORTS, 2021, 15 (01)
  • [6] Intraoperative detection of parathyroid glands by autofluorescence identification using image-based system: report of 15 cases
    Maksym Gorobeiko
    Andrii Dinets
    Journal of Medical Case Reports, 15
  • [7] Editorial: Artificial Intelligence for Medical Image Analysis of Neuroimaging Data
    Zeng, Nianyin
    Zuo, Siyang
    Zheng, Guoyan
    Ou, Yangming
    Tong, Tong
    FRONTIERS IN NEUROSCIENCE, 2020, 14
  • [8] Data Augmentation in Logit Space for Medical Image Classification with Limited Training Data
    Hu, Yangwen
    Zhong, Zhehao
    Wang, Ruixuan
    Liu, Hongmei
    Tan, Zhijun
    Zheng, Wei-Shi
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT V, 2021, 12905 : 469 - 479
  • [9] Displacement Analysis of Large-Aperture Mirror Using Image Data Augmentation and Explainable Artificial Intelligence
    Yang, Dabin
    Lee, Seongbae
    Kang, Jihyun
    Yoo, Byungcheol
    Lee, Jongsoo
    Transactions of the Korean Society of Mechanical Engineers, A, 2024, 48 (12) : 857 - 865
  • [10] Intraoperative Photodynamic Detection of Normal Parathyroid Glands Using 5-Aminolevulinic Acid
    Suzuki, Takeshi
    Numata, Tsutomu
    Shibuya, Mariko
    LARYNGOSCOPE, 2011, 121 (07): : 1462 - 1466