Optimizing the thermal performance of a double-pipe heat exchanger using twisted tapes with variable cuts and Fe3O4 nanofluid

被引:0
|
作者
Varma, K. P. V. Krishna [1 ]
Naveen, N. S. [2 ]
Kishore, P. S. [3 ]
Pujari, Satish [2 ]
Jogi, Krishna [4 ]
Raju, V. Dhana [5 ]
机构
[1] Raghu Engn Coll, Dept Mech Engn, Visakhapatnam 531162, Andhra Pradesh, India
[2] Lendi Inst Engn & Technol A, Dept Mech Engn, Vizianagaram 535005, Andhra Pradesh, India
[3] Andhra Univ, Andhra Univ Coll Engn A, Dept Mech Engn, Visakhapatnam 530003, India
[4] Rise Krishna Sai Prakasam Grp Inst, Dept Mech Engn, Ongole 523272, Andhra Pradesh, India
[5] Lakireddy Balireddy Coll Engn A, Dept Mech Engn, Mylavaram 521230, Andhra Pradesh, India
来源
JOURNAL OF THERMAL ENGINEERING | 2024年 / 10卷 / 05期
关键词
ANN; Cut Twisted Tapes; Friction Factor; Nanofluid; Nusselt Number; Reynolds Number; Taguchi; IRON-OXIDE NANOFLUIDS; FRICTION FACTOR; CIRCULAR TUBE; MASS-TRANSFER; ENHANCEMENT; INSERTS; FLOW;
D O I
10.14744/thermal.0000860
中图分类号
O414.1 [热力学];
学科分类号
摘要
This research work aims to optimize double pipe heat exchanger performance using Taguchi, ANOVA, and ANN. Experimental trials involved varying ferric oxide nanoparticles, cut radius, and volume-based flow rate. Twisted tapes with ratios of 3, 5, and 7 were placed within the tube. Assessed heat transfer characteristics included h, Nu, ff, and thermal performance factor. Taguchi, ANOVA, and ANN optimization techniques were applied to the experimental data. A Taguchi optimization using an L9 orthogonal array focused on input attributes (Vol % of nanoparticles, flow rate, radius of cut), with output attributes being heat transfer co-efficient (h), Nusselt number (Nu), friction factor(ff) and thermal performance factor. Results revealed a notable flow rate effect on enhancing h, Nu, and ff, while the addition of nanoparticles significantly influenced thermal performance. Taguchi and ANOVA were conducted using MINI Tab and ANN was implemented through MATLAB. Test data demonstrated that nanoparticle dispersants in nanofluid significantly improved heat transfer properties, consistent with the noteworthy improvement indicated by optimization techniques. The convective heat transfer coefficient parameter showed improvement with a coolant flow rate of 50.29% and a volume of nanoparticles at 27.32%. The enhancement of Nusselt number (Nu) was influenced by a coolant flow rate of 50.34% and a volume percent of nanoparticles at 34.25%. The thermal performance factor was significantly influenced by the volume percent of nanoparticles (79.75%) and the radius of cut (3.83%).The experimental data aligned well with findings from Taguchi and ANN.
引用
收藏
页码:1184 / 1197
页数:14
相关论文
共 50 条
  • [1] Investigation of Overlapped Twisted Tapes Inserted in a Double-Pipe Heat Exchanger Using Two-Phase Nanofluid
    Ghalambaz, Mehdi
    Arasteh, Hossein
    Mashayekhi, Ramin
    Keshmiri, Amir
    Talebizadehsardari, Pouyan
    Yaici, Wahiba
    NANOMATERIALS, 2020, 10 (09) : 1 - 17
  • [2] Thermal characteristics of perforated self-rotating twisted tapes in a double-pipe heat exchanger
    Zhang, Shaojie
    Lu, Lin
    Dong, Chuanshuai
    Cha, Seung Hyun
    APPLIED THERMAL ENGINEERING, 2019, 162
  • [3] Performance evaluation of a double-pipe heat exchanger fitted with self-rotating twisted tapes
    Zhang, Shaojie
    Lu, Lin
    Dong, Chuanshuai
    Cha, Seung Hyun
    APPLIED THERMAL ENGINEERING, 2019, 158
  • [4] Impact of variable fluid properties on forced convection of Fe3O4/CNT/water hybrid nanofluid in a double-pipe mini-channel heat exchanger
    Amin Shahsavar
    Ali Godini
    Pouyan Talebizadeh Sardari
    Davood Toghraie
    Hamzeh Salehipour
    Journal of Thermal Analysis and Calorimetry, 2019, 137 : 1031 - 1043
  • [5] Impact of variable fluid properties on forced convection of Fe3O4/CNT/water hybrid nanofluid in a double-pipe mini-channel heat exchanger
    Shahsavar, Amin
    Godini, Ali
    Sardari, Pouyan Talebizadeh
    Toghraie, Davood
    Salehipour, Hamzeh
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2019, 137 (03) : 1031 - 1043
  • [6] Experimental study of thermal performance factor for double-pipe heat exchanger using ZnO-water nanofluid
    Ahirwar, Brajesh Kumar
    Kumar, Arvind
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (15) : 8345 - 8364
  • [7] Theoretical and experimental studies of heat transfer in a double-pipe heat exchanger equipped with twisted tape and nanofluid
    Aghayari, Reza
    Maddah, Heydar
    Pourkiaei, Seyed Mohsen
    Ahmadi, Mohammad Hossein
    Chen, Lingen
    Ghazvini, Mahyar
    EUROPEAN PHYSICAL JOURNAL PLUS, 2020, 135 (02):
  • [8] Theoretical and experimental studies of heat transfer in a double-pipe heat exchanger equipped with twisted tape and nanofluid
    Reza Aghayari
    Heydar Maddah
    Seyed Mohsen Pourkiaei
    Mohammad Hossein Ahmadi
    Lingen Chen
    Mahyar Ghazvini
    The European Physical Journal Plus, 135
  • [9] Experimental study of exergetic performance of Al2O3 nanofluid in a double-pipe heat exchanger fitted by a new modified twisted tape
    Shirazi, Robab
    HEAT TRANSFER, 2020, 49 (05) : 2813 - 2830
  • [10] PERFORMANCE IMPROVEMENT OF SHELL AND TUBE HEAT EXCHANGER BY USING Fe3O4/WATER NANOFLUID
    Najim, Saad M.
    Hussein, Adnan M.
    Danook, Suad H.
    JOURNAL OF THERMAL ENGINEERING, 2023, 9 (01): : 24 - 32