50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes

被引:4
|
作者
Tuvshinbayar, Khorolsuren [1 ]
Ehrmann, Guido [2 ]
Ehrmann, Andrea [1 ]
机构
[1] Bielefeld Univ Appl Sci, Fac Engn & Math, D-33619 Bielefeld, Germany
[2] Virtual Inst Appl Res Adv Mat VIARAM, Bielefeld, Poland
来源
TEXTILES | 2022年 / 2卷 / 02期
关键词
electrocardiogram (ECG); Arduino; electrodes; conductive coating; conductive yarn; sensor; PERFORMANCE;
D O I
10.3390/textiles2020014
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
The electrocardiogram (ECG) is one of the most commonly measured biosignals. In particular, textile electrodes allow for the measuring of long-term ECG without skin irritation or other discomforts for the patient. Such textile electrodes, however, usually suffer from insufficient or unreliable skin contact. Thus, developing textile electrodes is impeded by the often-complicated differentiation between signal artifacts due to moving and breathing and artifacts related to unreliable skin contact. Here, we suggest a simple method of using 50/60 Hz power grid noise to evaluate the skin contact of different textile electrodes in comparison with commercial glued electrodes. We use this method to show the drying of wetted skin under an embroidered electrode as well as sweating of the originally dry skin under a coated electrode with high water vapor resistance.
引用
收藏
页码:265 / 274
页数:10
相关论文
共 50 条
  • [1] EMD-based 60-Hz noise filtering of the ECG
    Nimunkar, Amit J.
    Tompkins, Willis J.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1904 - 1907
  • [2] THE NATURAL BACKGROUND LEVELS OF 50/60 HZ RADIO NOISE
    FRASERSMITH, AC
    BOWEN, MM
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1992, 34 (03) : 330 - 337
  • [3] Noise performance of textile-based dry ECG recording electrodes
    Maji, Soumyajyoti
    Burke, Martin J.
    ELECTRONICS LETTERS, 2021, 57 (02) : 45 - 48
  • [4] Single Input Adaptive 50 Hz Noise Canceller from ECG Signal
    Mohamad-Ali, Bashar S.
    2013 FIRST INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRICAL, COMMUNICATION, COMPUTER, POWER, AND CONTROL ENGINEERING (ICECCPCE'13), 2013, : 64 - 69
  • [5] QUANTITATIVE ASSESSMENT OF INFLUENCE OF RANDOM AND 50-HZ NOISE ON ECG SIGNALS
    GYERGYEK, L
    VEZJAK, M
    PAVESIC, N
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (05): : 963 - 963
  • [6] The effect of 50/60 Hz notch filter application on human and rat ECG recordings
    Vale-Cardoso, A. S.
    Guimaraes, H. N.
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (01) : 44 - 58
  • [7] International Comparison of 50/60 Hz power (1996-1999)
    Oldham, N
    Nelson, T
    Bergeest, R
    Carranza, R
    Gibbes, M
    Jones, K
    Kyriazis, G
    Laiz, H
    Liu, L
    Lu, Z
    Pogliano, U
    Rydler, K
    Shapiro, E
    So, E
    Temba, M
    Wright, P
    2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 66 - 67
  • [8] CCEM-K5 Comparison of 50/60 Hz power
    Oldham, Nile
    Nelson, Thomas
    Zhang, Nien Fan
    Liu, Hung-kung
    METROLOGIA, 2003, 40
  • [9] An international comparison of 50/60 Hz power (1996-1999)
    Oldham, N
    Nelson, T
    Bergeest, R
    Ramm, G
    Carranza, R
    Corney, AC
    Gibbes, M
    Kyriazis, G
    Laiz, HM
    Liu, LX
    Lu, Z
    Pogliano, U
    Rydler, KE
    Shapiro, E
    So, E
    Temba, M
    Wright, P
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (02) : 356 - 360
  • [10] Adjustable 60Hz noise reduction and ECG signal amplification of a remote electrocardiogram system
    Bai, YW
    Cheng, CY
    Lu, CK
    Huang, CH
    Chen, YT
    Lin, YN
    IMTC/O3: PROCEEDINGS OF THE 20TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1 AND 2, 2003, : 197 - 202