Overview of partial discharge detection methods for XLPE cables

被引:0
|
作者
Wang, Xiaodi [1 ]
Zhou, Hong [1 ]
Yu, Jinhua [2 ]
Xu, Qiang [1 ]
Yang, Tianyu [1 ]
Zhou, Yunjie [1 ]
Yuan, Jialiang [1 ]
机构
[1] State Grid Shanghai Cable Co, Shanghai, Peoples R China
[2] State Grid Shanghai Urban Power Supply Co, Shanghai, Peoples R China
关键词
partial discharge; XLPE; magnetoresistance sensor; fiber optic sensing current sensing technology;
D O I
10.1145/3674225.3674235
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The insulation performance of Cross Linked Polyethylene (XLPE) cables determines the safety and reliability of the power system, and the degradation of its insulation performance will directly threaten the stability of the whole system. The insulation defects of cables will lead to the generation of partial discharges in cables, and it is of great significance to detect the local discharge signals of the problematic cables in time through the means of cable local discharge detection to reduce the hidden dangers of cable insulation and the safe operation of power grids. This paper describes the cross-linked polyethylene cable PD generation mechanism, characteristics, PD common detection methods are introduced in detail and compared and analyzed, for cable PD detection research and application to provide reference.
引用
收藏
页码:46 / 52
页数:7
相关论文
共 50 条
  • [1] On-line partial discharge detection in XLPE cables
    Luo, Junhua
    Ma, Cuijiao
    Qiu, Yuchang
    [J]. Gaodianya Jishu/High Voltage Engineering, 1999, 25 (04): : 32 - 34
  • [2] The Application of Partial Discharge Detection for the condition assessment of XLPE Power Cables
    Zhou, Xiaoli
    Qian, Yong
    Liu, Muqing
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (06): : 313 - 316
  • [4] Investigation and optimization of a sensor for partial discharge detection on high voltage XLPE cables
    Heinrich, R
    Jobava, R
    Kalkner, W
    Gheonjian, A
    [J]. PROCEEDINGS OF III INTERNATIONAL SEMINAR/WORKSHOP ON DIRECT AND INVERSE PROBLEMS OF ELECTROMAGNETIC AND ACOUSTIC WAVE THEORY, 1998, : 134 - 137
  • [5] A Novel Variable-frequency Resonant System for Partial Discharge Detection of XLPE Cables
    Lu, Yuxin
    Pu, Lu
    Zhao, Xuefeng
    Wang, Haochen
    Li, Tian
    Zhang, Hangwei
    Xu, Penglei
    [J]. 2019 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE 2019), 2019, : 376 - 380
  • [6] Simulation of Partial Discharge Propagation Characteristics in XLPE Cables and joints
    Liu, Bin
    Yang, Yuqi
    Chen, Xiping
    Sun, Zhenquan
    Li, Hongjie
    [J]. CURRENT DEVELOPMENT OF MECHANICAL ENGINEERING AND ENERGY, PTS 1 AND 2, 2014, 494-495 : 1436 - +
  • [7] Analysis Of Partial Discharge Signals In Medium Voltage XLPE Cables
    Ahmed, Zeeshan
    Hussain, Ghulam Amjad
    Lehtonen, Matti
    Varacka, Lukas
    Kudelcik, Jozef
    [J]. 2016 17TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2016, : 369 - 374
  • [8] Partial Discharge Characteristics of Electrical trees in XLPE Power Cables
    Zhou, Tianchun
    Yang, Lijun
    Liao, Ruijin
    Zhou, Quan
    Ye, Di
    [J]. 2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 93 - 96
  • [9] Detection of partial discharge signals in high voltage XLPE cables using time domain features
    Ambikairajah, R.
    Phung, B. T.
    Ravishankar, J.
    Blackburn, T. R.
    Liu, Z.
    [J]. 2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 364 - 367
  • [10] A Comparison of Partial Discharge Detection with 50 Hz and 0,1 Hz at XLPE Cables
    Sumereder, Christof
    [J]. CONFERENCE RECORD OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2012, : 619 - 622