An electrochemical biosensor with homogeneous dual amplification strategy for sensitive analysis of Pb 2+

被引:2
|
作者
Li, Mengjie [1 ,2 ,3 ]
Jia, Liping [1 ]
Shen, Guohao [1 ]
Zhou, You [1 ]
Gong, Zhuoyue [4 ]
An, Siyu [1 ]
Li, Xiang [1 ]
Zhang, Feng [1 ,2 ,3 ]
机构
[1] Chongqing Univ Sci & Technol, Sch Civil Engn & Architecture, Chongqing 401331, Peoples R China
[2] JINSHAN Sci & Technol Grp Co Ltd, Chongqing 401120, Peoples R China
[3] Chongqing Univ, Coll Optoelect Engn, Chongqing 400044, Peoples R China
[4] Chongqing Univ Sci & Technol, Sch Petr Engn, Chongqing 401331, Peoples R China
来源
关键词
Homogeneous strategy; Double amplification; Electrochemical biosensor; Lead ion; Rolling circle amplification; DNAzyme; LABEL-FREE;
D O I
10.1016/j.snb.2024.136225
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, a homogeneous double amplified electrochemical biosensing system was designed on the basis of rolling circle amplification (RCA) and DNAzyme-assisted Pb 2 + recycling amplification with the assistance of the signal molecule methylene blue (MB), which was used for highly sensitive analysis of Pb 2 + . In comparison with the conventional electrochemical biosensor, the homogeneous strategy adopted in this work can avoid the complex electrode modification and immobilization processes, and address the issues of the large steric hindrance and the restricted probe freedom on the sensing interface, thus achieving high recognition efficiency between recognition unit and target molecule as well as excellent detection performance of biosensor. In addition, the double amplified method assembling RCA and DNAzyme-assisted Pb 2 + recycling amplification can convert a handful of target Pb 2 + into abundant signal molecule MB, which would lead to the double amplification of output signal and the significantly enhanced detection sensitivity. Taking advantages of homogeneous dual amplification strategy, the constructed electrochemical biosensor for Pb 2 + analysis emerged a good linear range of 50 fM to 500 nM and a detection limit of 16.7 fM with significant selectivity and desirable stability. Impressively, the result presented herein comprise a valuable reference for establishing homogeneous multiple amplification model and constructing innovative biosensing system for sensitive detection of heavy metal ions.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Homogeneous electrochemical aptasensor based on a dual amplification strategy for sensitive detection of profenofos residues
    Jiao, Yancui
    Fu, Jiayun
    Hou, Wenjie
    Shi, Zhaoqiang
    Guo, Yemin
    Sun, Xia
    Yang, Qingqing
    Li, Falan
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (17) : 14642 - 14647
  • [2] Highly sensitive homogeneous electrochemical aptasensor for antibiotic residues detection based on dual recycling amplification strategy
    Wang, Xiuzhong
    Dong, Shanshan
    Gai, Panpan
    Duan, Rui
    Li, Feng
    BIOSENSORS & BIOELECTRONICS, 2016, 82 : 49 - 54
  • [3] Electrochemical biosensor for highly sensitive detection of cTnI based on a dual signal amplification strategy of ARGET ATRP and ROP
    Gao, Tianyu
    Zhou, Zhenbo
    Cheng, Di
    Liu, Yanju
    Yang, Huaixia
    Wang, Ying
    TALANTA, 2024, 266
  • [4] Immobilization-free electrochemical homogeneous aptasensor for highly sensitive detection of carcinoembryonic antigen by dual amplification strategy
    Zhang, Yuting
    Li, Hui
    Guo, Zongkang
    Wang, Xiaoli
    Zhou, Nandi
    ANALYTICA CHIMICA ACTA, 2023, 1274
  • [5] Ratiometrically homogeneous electrochemical biosensor based on the signal amplified strategy of dual DNA nanomachines for microRNA analysis
    Guan, Yan
    Wang, Fu Peng
    Chen, Zhi Xiong
    Yang, Tong
    Hu, Rong
    TALANTA, 2023, 254
  • [6] Ratiometrically homogeneous electrochemical biosensor based on the signal amplified strategy of dual DNA nanomachines for microRNA analysis
    Guan, Yan
    Wang, Fu Peng
    Chen, Zhi Xiong
    Yang, Tong
    Hu, Rong
    TALANTA, 2023, 254
  • [7] Homogeneous electrochemical biosensor for microRNA based on enzyme-driven cascaded signal amplification strategy
    Huang, Yitong
    Huang, Xiaocui
    Zheng, Huixia
    Lin, Cuiying
    Lin, Zhenyu
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (18) : 4681 - 4688
  • [8] Homogeneous electrochemical biosensor for microRNA based on enzyme-driven cascaded signal amplification strategy
    Yitong Huang
    Xiaocui Huang
    Huixia Zheng
    Cuiying Lin
    Zhenyu Lin
    Analytical and Bioanalytical Chemistry, 2021, 413 : 4681 - 4688
  • [9] An electrochemical biosensor for the sensitive detection of specific DNA based on a dual-enzyme assisted amplification
    Lin, Chunshui
    Chen, Yiying
    Cai, Zhixiong
    Luo, Feng
    Wang, Yiru
    Chen, Xi
    ELECTROCHIMICA ACTA, 2014, 147 : 785 - 790
  • [10] A sensitive electrochemical biosensor based on Exo III cyclic amplification strategy for Phaeocystis globosa detection
    Liu, Hongjie
    Fu, Hao
    Zhang, Yibo
    Wang, Shaopeng
    Yang, Kedi
    Wang, Liwei
    MICROCHIMICA ACTA, 2025, 192 (04)