Development of an amperometric biosensor for the detection of Bacillus anthracis spores

被引:0
|
作者
Ortatatli, Mesut [1 ,3 ]
Saatci, Ebru [2 ]
Kilic, Zahir [1 ]
Kenar, Levent [1 ]
机构
[1] Univ Hlth Sci, Dept Med CBRN Def, TR-06018 Ankara, Turkiye
[2] Erciyes Univ, Fac Sci, Dept Biol, TR-38039 Kayseri, Turkiye
[3] Gulhane Egitimve Arastirma Hastanesi KBRN AD Bsklg, Ankara, Turkiye
关键词
Amperometry; Bacillus anthracis; Immunosensor; Magnetic beads; Screen printed electrode; Spore; RAPID DETECTION; FRANCISELLA-TULARENSIS; SYSTEM;
D O I
10.1016/j.diagmicrobio.2024.116473
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Introduction: Due to most likely use of Bacillus anthracis in biological terrorism agents, the rapid and sensitive detection of its spores is crucial in both taking prophylactic measures and proper treatment. This study aimed to develop an amperometric electrochemical immunosensor for the detection of B. anthracis spores. Methods: A new amperometric biosensor was designed using a combination of magnetic beads and multiplex screen-printed electrodes. This method measures changes in current intensity resulting from oxidation and reduction in the working electrode directly to spore concentrations. Results: A standard curve was formed to test the number of live spores between 2 x 102-2 x 104 spores/ml concentrations. LOD and LOQ values were found to be 92 and 272 spores/ml, respectively. No cross-reactions were seen for Bacillus subtilis, Bacillus cereus and Bacillus thuringiencis spores. Conclusions: It is shown that the designed Anthrax immunosensor has high sensitivity and selectivity with rapid detection results.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Environmental detection of Bacillus anthracis spores
    Agarwal, GS
    Kamboj, DV
    Alam, SI
    Dixit, M
    Singh, L
    [J]. CURRENT SCIENCE, 2002, 83 (06): : 697 - 699
  • [2] Amperometric Detection of Bacillus anthracis Spores: A Portable, Low-Cost Approach to the ELISA
    Peckham, Gabriel D.
    Hew, Brian E.
    Waller, David F.
    Holdaway, Charlie
    Jen, Michael
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY, 2013, 2013
  • [3] Detection of Bacillus anthracis spores in soil by PCR
    Sjostedt, A
    Eriksson, U
    Ramisse, V
    Garrigue, H
    [J]. FEMS MICROBIOLOGY ECOLOGY, 1997, 23 (02) : 159 - 168
  • [4] Development of automated amperometric detection of antibodies against Bacillus anthracis protective antigen
    Aguilar, Zoraida P.
    Sirisena, Mali
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (02) : 507 - 515
  • [5] Development of automated amperometric detection of antibodies against Bacillus anthracis protective antigen
    Zoraida P. Aguilar
    Mali Sirisena
    [J]. Analytical and Bioanalytical Chemistry, 2007, 389 : 507 - 515
  • [6] Development of Antibodies against Anthrose Tetrasaccharide for Specific Detection of Bacillus anthracis Spores
    Kuehn, Andrea
    Kovac, Pavol
    Saksena, Rina
    Bannert, Norbert
    Klee, Silke R.
    Ranisch, Heidrun
    Grunow, Roland
    [J]. CLINICAL AND VACCINE IMMUNOLOGY, 2009, 16 (12) : 1728 - 1737
  • [7] Fast and Sensitive Detection of Bacillus anthracis Spores by Immunoassay
    Morel, Nathalie
    Volland, Herve
    Dano, Julie
    Lamourette, Patricia
    Sylvestre, Patricia
    Mock, Michele
    Creminon, Christophe
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2012, 78 (18) : 6491 - 6498
  • [8] Landscape phage-based magnetostrictive biosensor for detecting Bacillus anthracis spores
    Wan, JH
    Fiebor, B
    Chin, BA
    Chen, IH
    Brigati, J
    Petrenko, VA
    [J]. 2005 IEEE SENSORS, VOLS 1 AND 2, 2005, : 1308 - 1311
  • [9] Inactivation of Bacillus anthracis spores
    Whitney, EAS
    Beatty, ME
    Taylor, TH
    Weyant, R
    Sobel, J
    Arduino, MJ
    Ashford, DA
    [J]. EMERGING INFECTIOUS DISEASES, 2003, 9 (06) : 623 - 627
  • [10] Bacteriophage modified biosensor for Bacillus anthracis spore detection
    Wan, Jiehui
    Yang, Hong
    Chen, Hsuan
    Petrenko, Valery A.
    Chin, Bryan A.
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231