A multianalyte LC-MS/MS method for accurate quantification of Nitrosamines in Olmesartan tablets

被引:2
|
作者
Pawar, Namdev [1 ]
Bhardwaj, Aparna [1 ]
Vora, Amisha [2 ]
Sharma, Sanjay [3 ]
机构
[1] Chauhan Inst Sci & Amrutben Jivanlal Coll Commerce, Mithibai Coll Arts, Dept Chem, Vile Parle West, Mumbai 400056, India
[2] NMIMS, Shobhaben Pratapbhai Patel Sch Pharm & Technol Man, Dept Chem, Vile Parle West, Mumbai 400056, India
[3] NMIMS, Shobhaben Pratapbhai Patel Sch Pharm & Technol Man, Dept Qual Assurance, Vile Parle West, Mumbai 400056, India
关键词
Olmesartan; Nitrosamines; LC-MS/MS; Analysis; QUANTITATIVE-DETERMINATION; PHARMACEUTICAL PRODUCTS; HUMAN PLASMA; RP-HPLC; HYDROCHLOROTHIAZIDE; MEDOXOMIL; AMLODIPINE; URINE; NDMA;
D O I
10.1016/j.chroma.2024.465176
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This research summaries the development, optimization and validation of liquid chromatography tandem mass spectrometric (LC-MS/MS) method for concurrent measurement of seven nitrosamines viz; NDMA, NDEA, NDIPA, NDPA, NEIPA, NMPA & NMBA in Olmesartan tablet. Controlling these nitrosamines at trace levels is imperative for ensuring the safety of drug substances and products for consumption. Various regulatory authorities stress the significance of utilizing highly sensitive analytical methods to precisely measure nitrosamines at trace levels. The method applied effective chromatographic separation and optimized parameters for mass spectrometric detection. Detection was carried out using APCI positive ion mode. Chromatographic separation was achieved using a Thermo Accucore PFP column (150 mm x 4.6 mm, 2.6 mu), with a simple gradient elution of mobile phase consisting of 0.1 % formic acid in water (mobile phase A) and methanol (mobile phase B). The total run time was 20 min, with a flow rate of 0.800 mL/min. The method was validated according to the International Council on Harmonisation (ICH Q2 (R2)) guidelines. The established method demonstrated excellent linearity (R-2> 0.99) and sensitivity for all the nitrosamines. Detection and quantification limits were sufficiently low for trace nitrosamine levels having good S/N ratio. The method showed good accuracy in Olmesartan tablet samples, with recoveries ranges between 80 % to 120 %. The new analytical approach has exceptional repeatability and reliability, making it possible to precisely quantify the levels of seven nitrosamines in Olmesartan medoxomil tablets in a single analytical run.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A multi-analyte LC-MS/MS method for screening and quantification of nitrosamines in sartans
    Chang, Shu-Han
    Chang, Ching-Chia
    Wang, Li-Jing
    Chen, Wei-Ching
    Fan, Shu-Yu
    Zang, Chi-Zong
    Hsu, Ya-Hui
    Lin, Mei-Chih
    Tseng, Su-Hsiang
    Wang, Der-Yuan
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2020, 28 (02) : 98 - 107
  • [2] LC-ESI-MS/MS method for the accurate quantification of eight nitrosamines in pharmaceutical products
    Danis, Ibrahim
    Unal, Durisehvar Ozer
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2025,
  • [3] Comparison of accurate mass LC-MS and MRM LC-MS/MS for the quantification of a therapeutic small interfering RNA
    Wheller, Robert
    Summerfield, Scott
    Barfield, Matt
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2013, 345 : 45 - 53
  • [4] Identification of losartan degradates in stressed tablets by LC-MS and LC-MS/MS
    Zhao, ZX
    Wang, QX
    Tsai, EW
    Qin, XZ
    Ip, D
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (1-2) : 129 - 136
  • [5] An accurate and robust LC-MS/MS method for the quantification of chlorfenvinphos, ethion and linuron in liver samples
    Kadar, Ali
    Peyre, Ludovic
    de Souza, Georges
    Wortham, Henri
    Doumenq, Pierre
    Rahmani, Roger
    CHEMOSPHERE, 2017, 184 : 20 - 26
  • [6] A Selective and Accurate LC-MS/MS Method for Simultaneous Quantification of Valsartan and Hydrochlorothiazide in Human Plasma
    Haque, Anzarul
    Iqbal, Muzaffar
    Alamoudi, Mariam K. K.
    Alam, Prawez
    SEPARATIONS, 2023, 10 (02)
  • [7] A Validated Multianalyte LC-MS/MS Method for Quantification of 25 Mycotoxins in Cassava Flour, Peanut Cake and Maize Samples
    Ediage, Emmanuel Njumbe
    Di Mavungu, Jose Diana
    Monbaliu, Sofie
    Van Peteghem, Carlos
    De Saeger, Sarah
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (10) : 5173 - 5180
  • [8] NEW LC-MS/MS METHOD FOR THE DETERMINATION OF EIGHT NITROSAMINES IN DRINKING WATER
    Galaon, T.
    Cruceru, L.
    Petre, J.
    Pascu, L. F.
    Iancu, V. I.
    Niculescu, M.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2016, 17 (01): : 74 - 82
  • [9] DEVELOPMENT OF LC-MS/MS REFERENCE METHOD FOR THE QUANTIFICATION OF LIPOPROTEIN(A)
    Marcovina, S. M.
    Vaisar, T.
    Clouet-Foraison, N.
    Hoofnagle, A.
    Koschinsky, M. L.
    Boffa, M. B.
    Lowenthal, M.
    ATHEROSCLEROSIS, 2021, 331 : E119 - E119
  • [10] LC-MS/MS Method for the Quantification of Infliximab in Human Blood
    Nakamura, H.
    Araki, T.
    Nakamura, T.
    Yamamoto, K.
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 724 - 724