Quantitative error analysis for computer assisted navigation: A feasibility study

被引:18
|
作者
Gueler, Oe [1 ]
Perwoeg, M. [2 ]
Kral, F. [2 ]
Schwarm, F. [3 ]
Bardosi, Z. R. [2 ]
Goebel, G. [4 ]
Freysinger, W. [2 ]
机构
[1] Childrens Natl Med Ctr, Washington, DC 20010 USA
[2] Med Univ Innsbruck, Univ ENT Clin, Visualizat Lab 4D, A-6020 Innsbruck, Austria
[3] Tech Univ Munich, Dept Neurosurg, Klinikum Rechts Isar, D-81675 Munich, Germany
[4] Med Univ Innsbruck, Dept Med Stat Informat & Hlth Econ MSIG, A-6020 Innsbruck, Austria
关键词
application accuracy; navigation; human localization error; registration; TARGET REGISTRATION ERROR; IMAGE-GUIDED NEUROSURGERY; LATERAL SKULL BASE; APPLICATION ACCURACY; AIDED SURGERY; LOCALIZATION; BONE; 3D-NAVIGATION; PHANTOM; SYSTEM;
D O I
10.1118/1.4773871
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The benefit of computer-assisted navigation depends on the registration process, at which patient features are correlated to some preoperative imagery. The operator-induced uncertainty in localizing patient features-the user localization error (ULE)-is unknown and most likely dominating the application accuracy. This initial feasibility study aims at providing first data for ULE with a research navigation system. Methods: Active optical navigation was done in CT-images of a plastic skull, an anatomic specimen (both with implanted fiducials), and a volunteer with anatomical landmarks exclusively. Each object was registered ten times with 3, 5, 7, and 9 registration points. Measurements were taken at 10 (anatomic specimen and volunteer) and 11 targets (plastic skull). The active NDI Polaris system was used under ideal working conditions (tracking accuracy 0.23 mm root-mean-square, RMS; probe tip calibration was 0.18 mm RMS). Variances of tracking along the principal directions were measured as 0.18 mm(2), 0.32 mm(2), and 0.42 mm(2). ULE was calculated from predicted application accuracy with isotropic and anisotropic models and from experimental variances, respectively. Results: The ULE was determined from the variances as 0.45 mm (plastic skull), 0.60 mm (anatomic specimen), and 4.96 mm (volunteer). The predicted application accuracy did not yield consistent values for the ULE. Conclusions: Quantitative data of application accuracy could be tested against prediction models with iso- and anisotropic noise models and revealed some discrepancies. This could potentially be due to the facts that navigation and one prediction model wrongly assume isotropic noise (tracking is anisotropic), while the anisotropic noise prediction model assumes an anisotropic registration strategy (registration is isotropic in typical navigation systems). The ULE data are presumably the first quantitative values for the precision of localizing anatomical landmarks and implanted fiducials. Submillimetric localization is possible for implanted screws; anatomic landmarks are not suitable for high-precision clinical navigation. (c) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4773871]
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Computer-assisted fluoroscopic navigation of pedicle screw insertion - An in vivo feasibility study
    Fu, TS
    Chen, LH
    Wong, CB
    Lai, PL
    Tsai, TT
    Niu, CC
    Chen, WJ
    ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (06): : 730 - 735
  • [2] Syndesmosis reduction by computer-assisted orthopaedic surgery with navigation: Feasibility and accuracy in a cadaveric study
    Dubois-Ferriere, Victor
    Gamulin, Axel
    Chowdhary, Ashwin
    Fasel, Jean
    Stern, Richard
    Assal, Mathieu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (12): : 2694 - 2699
  • [3] Computer-assisted needle navigation for pediatric internal jugular central venous cannulation: A feasibility study
    Gallo, Christopher
    Foroughi, Pezhman
    Meagher, Elisabeth
    Vellody, Ranjith
    Yadav, Bhupender
    Ho, Anthony
    Demir, Alican
    Heisenberg, Dorothee
    Cleary, Kevin
    Sharma, Karun
    JOURNAL OF VASCULAR ACCESS, 2020, 21 (06): : 931 - 937
  • [4] Navigation of Acetabular Re-orientation in Periacetabular Osteotomy - a Computer-assisted Feasibility Study on Cadavers
    Ecker, Timo Michael
    Puls, Marc
    Bastian, Johannes Dominik
    Keel, Marius Johann Baptist
    Tannast, Moritz
    Siebenrock, Klaus Arno
    SWISS MEDICAL WEEKLY, 2012, 142 : S2 - S2
  • [5] Computer assisted quantitative analysis of newspaper articles
    Higuchi, K
    SOCIOLOGICAL THEORY AND METHODS, 2004, 19 (02) : 161 - 176
  • [6] Computer-assisted navigation to solitary pulmonary nodules with the LungPoint™ system - a feasibility trial
    Eberhardt, R.
    Kahn, N.
    Gompelmann, D.
    Herth, F. J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181
  • [7] Computer-assisted Navigation For Transbronchial Needle Aspiration With The LungPoint™ System - A Feasibility Trial
    Herth, F. J.
    Gompelmann, D.
    Kahn, N.
    Eberhardt, R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181
  • [8] Ultrasound-based computer navigation of the acetabular component: a feasibility study
    Wassilew, Georgi I.
    Heller, Markus O.
    Hasart, Olaf
    Perka, Carsten
    Suedhoff, Ingrid
    Janz, Viktor
    Duda, Georg N.
    Koenig, Christian
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (04) : 517 - 525
  • [9] Ultrasound-based computer navigation of the acetabular component: a feasibility study
    Georgi I. Wassilew
    Markus O. Heller
    Olaf Hasart
    Carsten Perka
    Ingrid Südhoff
    Viktor Janz
    Georg N. Duda
    Christian König
    Archives of Orthopaedic and Trauma Surgery, 2012, 132 : 517 - 525
  • [10] Computer-Assisted Approaches for Uterine Fibroid Segmentation in MRgFUS Treatments: Quantitative Evaluation and Clinical Feasibility Analysis
    Rundo, Leonardo
    Militello, Carmelo
    Tangherloni, Andrea
    Russo, Giorgio
    Lagalla, Roberto
    Mauri, Giancarlo
    Gilardi, Maria Carla
    Vitabile, Salvatore
    QUANTIFYING AND PROCESSING BIOMEDICAL AND BEHAVIORAL SIGNALS, 2019, 103 : 229 - 241