The Suppression of Flow-Induced Vibrations for a Single and Two Tandem-Arrangement Cylinders Using Three Splitter Plates

被引:0
|
作者
Hu, Zhongming [1 ]
Wang, Jiasong [2 ,3 ]
Sun, Yuankun [4 ]
Lin, Ke [2 ,3 ]
机构
[1] Huanghuai Univ, Coll Civil Engn & Architecture, Zhumadian 463000, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Naval Architecture Ocean & Civil Engn, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, MOE Key Lab Hydrodynam, Shanghai 200240, Peoples R China
[4] Ocean Univ China, Coll Engn, Qingdao 266100, Peoples R China
基金
中国国家自然科学基金;
关键词
flow-induced vibration; suppression method; splitter plates; vortex-induced vibration; VORTEX-INDUCED VIBRATION; CIRCULAR-CYLINDER;
D O I
10.3390/jmse12091487
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
Some very useful methods for suppressing the flow-induced vibration (FIV) of a single cylinder are known to potentially have a limited efficiency for tandem-arrangement cylinders. In this paper, three splitter plates uniformly attached around a cylinder with an angle of 120 degrees are proposed to suppress the FIVs of both a single cylinder and two tandem-arrangement cylinders in a wind tunnel at Re = 4000-45,200. The splitter plates' length to diameter ratios, L/Ds (where L is the length of the splitter plate and D is the cylinder diameter), are set from 0.1 to 0.8. The results show that the proposed method not only effectively suppresses the vortex-induced vibration (VIV) for a single cylinder, but also successfully mitigates the wake-induced galloping (WIG) for two tandem-arrangement cylinders. The vibrations of the single cylinders are effectively suppressed, consistently achieving suppression efficiencies over 95% for L/Ds = 0.2-0.8, with a notable peak efficiency of 98.4% at L/D = 0.2. For the two tandem-arrangement cylinders at S/D = 4.0 (where S is the center-to-center spacing between the two cylinders), the suppression efficiencies of the upstream cylinder exceed 96% for L/D = 0.2-0.8, with an optimal efficiency of 97.4% at L/D = 0.6. The downstream cylinder exhibits vibration only at L/Ds = 0.1, 0.2, and 0.4, resulting in suppression efficiencies of 80.3%, 67.1%, and 91.0%. The vibrations remain fully suppressed throughout the entire reduced velocity range for L/Ds = 0.6-0.8, reaching an optimal efficiency of 98.7% at L/D = 0.6. Three regimes of fs/fn characteristics can be classified for the single cylinder, and the wake structures show that shear layers develop along the front plate before attaching on the cylinder and are then offset to either side of the cylinder by the two rear splitter plates, contributing to the absence of periodic vortex shedding.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Flow-induced vibration of two circular cylinders in tandem arrangement. Part 2: Suppression of vibrations
    Kim, Sangil
    Alam, Md Mahbub
    Sakamoto, Hiroshi
    Zhou, Yu
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2009, 97 (5-6) : 312 - 319
  • [2] Characteristics and suppression of flow-induced vibrations of two circular cylinders in tandem arrangement (2nd report, suppression of flow-induced vibrations in cross-flow vibration)
    Kim, Sangil
    Sakamoto, Hiroshi
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2006, 72 (09): : 2164 - 2171
  • [3] FLOW-INDUCED VIBRATIONS OF TWO TANDEM CYLINDERS IN A CHANNEL
    Jiang, Ren-Jie
    THERMAL SCIENCE, 2012, 16 (05): : 1377 - 1381
  • [4] Poiseuille flow-induced vibrations of two cylinders in tandem
    Lin, Jianzhong
    Jiang, Renjie
    Chen, Zhongli
    Ku, Xiaoke
    JOURNAL OF FLUIDS AND STRUCTURES, 2013, 40 : 70 - 85
  • [5] Three-dimensional computation for flow-induced vibrations of two circular cylinders in tandem arrangement with narrow spacing
    Kondo, Norio
    JOURNAL OF SOUND AND VIBRATION, 2024, 578
  • [6] Characteristics and suppression of flow-induced vibrations of two circular cylinders in tandem arrangement (1st report, characteristics of flow-induced vibrations in cross-flow vibration)
    Kim, Sangil
    Sakamoto, Hiroshi
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2006, 72 (02): : 314 - 321
  • [7] Flow-induced vibrations of three and four long flexible cylinders in tandem arrangement: An experimental study
    Wang, Enhao
    Xu, Wanhai
    Yu, Yang
    Zhou, Lidan
    Incecik, Atilla
    OCEAN ENGINEERING, 2019, 178 : 170 - 184
  • [8] Numerical investigation of flow-induced vibrations of two cylinders in tandem arrangement with full wake interference
    Lin, Ke
    Wang, Jiasong
    Zheng, Hanxu
    Sun, Yuankun
    PHYSICS OF FLUIDS, 2020, 32 (01)
  • [9] Flow-induced vibration suppression for a single cylinder and one-fixed-one-free tandem cylinders with double tail splitter plates
    Hu, Zhongming
    Wang, Jiasong
    Sun, Yuankun
    Zheng, Hanxu
    JOURNAL OF FLUIDS AND STRUCTURES, 2021, 106
  • [10] Flow-induced vibrations of two circular cylinders in tandem arrangement. Part 1: Characteristics of vibration
    Kim, Sangil
    Alam, Md Mahbub
    Sakamoto, Hiroshi
    Zhou, Yu
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2009, 97 (5-6) : 304 - 311