Wearable Device and Algorithm for Fall Prevention: Monitoring Fall Risk Using Foot Motion Measured by an In-Shoe Motion Sensor

被引:0
|
作者
Huang, Chenhui [1 ]
Nihey, Fumiyuki [1 ]
Inai, Takuma [2 ]
Kobayashi, Yoshiyuki [3 ]
Fujita, Koji [4 ]
Yamamoto, Akiko [5 ]
Fujimoto, Masahiro [2 ]
Fukushi, Kenichiro [1 ]
Nakahara, Kentaro [1 ]
机构
[1] NEC Corp Ltd, Biometr Res Lab, Abiko, Chiba 2701198, Japan
[2] Natl Inst Adv Ind Sci & Technol, Hlth & Med Res Inst, Takamatsu, Kagawa 7610395, Japan
[3] Natl Inst Adv Ind Sci & Technol, Human Augmentat Res Ctr, Kashiwa, Chiba 2770882, Japan
[4] Tokyo Med & Dent Univ, Inst Res Innovat, Open Innovat Ctr, Div Med Design Innovat, Tokyo 1138510, Japan
[5] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Dept Orthopaed & Spinal Surg, Tokyo 1138510, Japan
关键词
Fall risk; gait analysis; in-shoe motion sensor (IMS); older adults; principal component analysis (PCA); OLDER-ADULTS; INERTIAL SENSORS; INJURIOUS FALLS; BALANCE; EPIDEMIOLOGY; PERFORMANCE; MOBILITY; PEOPLE; GO;
D O I
10.1109/TIM.2024.3436068
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Falls are a significant public health concern worldwide, particularly for older adults. In this study, we aim to create an effective quantitative indicator for long-term daily fall risk assessment suitable for use with in-shoe motion sensors (IMSs). We used the likelihood of an individual being a faller (ranging from 0 to 1) as a representation of the quantitative fall risk indicator. This indicator was constructed using data from 40 nonfallers and 24 fallers, all female older adults with distal radius fractures (DRFs) caused by falls within 6 months (denoted as 0 and 1, respectively). The indicator was determined using Fisher's discriminant, na & iuml;ve Bayesian, or logistic regression approaches. Predictors were derived from four types of gait parameters and four types of physical ability metrics, all of which can be measured or estimated using IMS-measured gait. To prevent overfitting, we performed principal component analysis (PCA) on the predictors. To validate our method, we assessed Pearson's correlation between clinical experts-rated fall risk scores and the constructed fall risk indicator using a separate group of 19 older female adults. The Pearson's correlation obtained was 0.766. We successfully developed a fall risk indicator using IMS-measured gait, demonstrating the potential for IMSs to achieve long-term daily fall risk assessment.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Assessment of over-pronated/over-supinated foot using foot-motion measured by an in-shoe motion sensor
    Huang, Chenhui
    Wang, Zhenwei
    Fukushi, Kenichiro
    Nihey, Fumivuki
    Kajitani, Hiroshi
    Nakahara, Kentaro
    [J]. 2021 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (IEEE BIOCAS 2021), 2021,
  • [2] ENHANCING GERIATRIC FALL RISK ASSESSMENT WITH WEARABLE MOTION SENSOR DATA
    Marschollek, M.
    Schulze, M. D.
    Gietzelt, M.
    Wolf, K.
    Nemitz, G.
    Schwabedissen, H. Meyer Zu
    [J]. GERONTOLOGIST, 2011, 51 : 525 - 525
  • [3] Feature selection, construction and test of model for estimating lower extremity strength of older adults using foot motion measured by an in-shoe motion sensor
    Huang, Chenhui
    Nihey, Fumiyuki
    Fukushi, Kenichiro
    Kajitani, Hiroshi
    Nozaki, Yoshitaka
    Ihara, Kazuki
    Nakahara, Kentaro
    [J]. 2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [4] Healthcare Application of In-Shoe Motion Sensor for Older Adults: Frailty Assessment Using Foot Motion during Gait
    Huang, Chenhui
    Nihey, Fumiyuki
    Ihara, Kazuki
    Fukushi, Kenichiro
    Kajitani, Hiroshi
    Nozaki, Yoshitaka
    Nakahara, Kentaro
    [J]. SENSORS, 2023, 23 (12)
  • [5] The impact of first metatarsophalangeal angle on the gait features measured by an in-shoe motion sensor
    Huang, Chenhui
    Fukushi, Kenichiro
    Wang, Zhenwei
    Kajitani, Hiroshi
    Pokka, Hannah
    Narasaki, Hiroko
    Nihey, Fumiyuki
    Nakano, Hiroaki
    Nakahara, Kentaro
    [J]. 2020 IEEE SENSORS, 2020,
  • [6] A Wearable Inertial Sensing Device for Fall Detection and Motion Tracking
    Kumar, Praveen
    Pandey, Prem C.
    [J]. 2013 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2013,
  • [7] Estimation of knee flexion features using foot motion data from in-shoe motion sensors
    Ihara, Kazuki
    Huang, Chenhui
    Wang, Zhenwei
    Nihey, Fumiyuki
    Fukushi, Kenichiro
    Kajitani, Hiroshi
    Nozaki, Yoshitaka
    Nakahara, Kentaro
    [J]. 2023 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC, 2023,
  • [8] Poster: Foot-Floor Friction Based Walking Surface Detection for Fall Prevention Using Wearable Motion Sensors
    Wang, Shuangquan
    Zhou, Gang
    [J]. 2023 IEEE/ACM CONFERENCE ON CONNECTED HEALTH: APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES, CHASE, 2023, : 179 - 180
  • [9] Designing an in-shoe sensor system to identify ankle spraining risk and motion, and a smart ankle protector for ankle sprain prevention
    Fong, Daniel Tik-Pui
    Chan, Kai-Ming
    [J]. TEXTILE BIOENGINEERING AND INFORMATICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2008, : 1185 - 1187
  • [10] Analyzing Optimal Wearable Motion Sensor Placement for Accurate Classification of Fall Directions
    Teng, Sokea
    Kim, Jung-Yeon
    Jeon, Seob
    Gil, Hyo-Wook
    Lyu, Jiwon
    Chung, Euy Hyun
    Kim, Kwang Seock
    Nam, Yunyoung
    [J]. Sensors, 2024, 24 (19)