Determination of <sc>l</sc>-Tryptophan Methyl Ester Hydrochloride Solubility in 12 Pure Solvent Systems from 283.15 to 323.15 K

被引:0
|
作者
Xing, Xin [1 ]
Zhao, Long [1 ]
Li, Junjie [1 ]
Xiao, Yusheng [1 ]
Ding, Min [1 ]
Li, Bingbing [1 ]
Wang, Peng [1 ,2 ]
机构
[1] Changchun Univ Technol, Sch Chem Engn, Changchun 130012, Jilin, Peoples R China
[2] Changchun Univ Technol, Adv Inst Mat Sci, Changchun 130012, Jilin, Peoples R China
来源
关键词
THERMODYNAMICS; TEMPERATURES; PARAMETERS; WATER;
D O I
10.1021/acs.jced.4c00210
中图分类号
O414.1 [热力学];
学科分类号
摘要
Research on the solubility behavior of l-tryptophan methyl ester hydrochloride, an important pharmaceutical intermediate, is necessary for the design of its crystallization and separation processes. The solubility data of l-tryptophan methyl ester hydrochloride were measured by the static gravimetric method in 12 pure solvents (methanol, water, ethanol, n-propanol, n-butanol, isobutanol, sec-butanol, isopropanol, propanone, 2-butanone, ethyl acetate, and acetonitrile) at 283.2-323.2 K and 101.2 kPa. The solubility of l-tryptophan methyl ester hydrochloride in all studied solvents increases with the increase of temperature. In addition, the solubility sequence of l-tryptophan methyl ester hydrochloride at 298.2 K is methanol (0.033403 mol/mol) > water (0.011939 mol/mol) > ethanol (0.007368 mol/mol) > n-propanol (0.003708 mol/mol) > n-butanol (0.002632 mol/mol) > isobutanol (0.001716 mol/mol) > sec-butanol (0.001651 mol/mol) > isopropanol (0.001573 mol/mol) > propanone (0.000605 mol/mol) > 2-butanone (0.000401 mol/mol) > ethyl acetate (0.000074 mol/mol) > acetonitrile (0.000065 mol/mol). Methanol had the highest solubility of 0.033403 mol/mol, while acetonitrile had the lowest solubility of 0.000065 mol/mol. The main factors influencing the solubility behavior include the empirical solvent polarity parameters (E-T(30)), hydrogen bonding, and cohesive energy density. Three solubility fitting models were used to correlate the experimental mole fraction solubility data, including the modified Apelblat model, the nonrandom two liquid (NRTL) model, and the Margules model. Furthermore, mixing thermodynamic characteristics of l-tryptophan methyl ester hydrochloride in selected solvents were calculated by the NRTL model, and the results indicated that the mixing process was spontaneous and driven by entropy. In order to choose the best model for l-tryptophan methyl ester hydrochloride, the relative applicability of these models was evaluated by the Akaike Information Criterion (AIC). The study of the solubility of l-tryptophan methyl ester hydrochloride not only enriches the solubility database and provides guidance and basis for crystallization but also provides rich solubility data for machine learning models.
引用
收藏
页码:3116 / 3126
页数:11
相关论文
共 50 条
  • [1] Solubility Determination and Thermodynamic Modeling of <sc>L</sc>-Phenylalanine in 12 Monosolvents from 283.15 to 323.15 K
    Zhang, Shujing
    Liu, Dandan
    Wang, Yongjie
    Wang, Jiaxin
    Zhao, Long
    Xing, Xin
    Li, Junjie
    Xiao, Yusheng
    Cong, Xiaolu
    Li, Zhenyu
    Wang, Peng
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2024, 69 (03): : 1252 - 1262
  • [2] Determination of L-Glutamine Solubility in 12 Pure Solvent Systems from 283.15 to 323.15 K
    Liu, Dandan
    Hu, Shen
    Zhao, Yue
    Wang, Yongjie
    Zhang, Shujing
    Wang, Jiaxin
    Wang, Peng
    Li, Zhenyu
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2023, 68 (06): : 1419 - 1427
  • [3] Solubility Behavior, Hansen Solubility Parameters, and Thermodynamic Modeling of <sc>l</sc>-Leucine in 12 Monosolvents from 283.15 to 323.15 K
    Wang, Jiaxin
    Li, Junjie
    Liu, Dandan
    Wang, Yongjie
    Zhang, Shujing
    Liu, Yang
    Zhao, Long
    Xing, Xin
    Zhi, Minjie
    Wang, Peng
    Hou, Xu
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2023, 68 (10): : 2725 - 2734
  • [4] Solubility Behavior of L-Homophenylalanine Ethyl Ester Hydrochloride in 12 Individual Solvents from 283.15 to 323.15 K
    Guo, Ying
    He, Hui
    Huang, Haishuang
    Qiu, Jingxuan
    Han, Jiaming
    Hu, Shen
    Liu, Haoyou
    Zhao, Yue
    Wang, Peng
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2021, 66 (09): : 3629 - 3636
  • [5] Solubility Measurement, Correlation, and Computational Analysis of Methyl <sc>l</sc>-Leucinate Hydrochloride in 12 Pure Solvents
    Wang, Jiaxin
    Liu, Dandan
    Wang, Yongjie
    Zhang, Shujing
    Jing, Mingyu
    Li, Zhenyu
    Wang, Peng
    Hou, Xu
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2024, 69 (05): : 1957 - 1965
  • [6] Determination of l-Valine Solubility in 12 Monosolvent Systems at Multiple Temperatures from 283.15 to 323.15 K
    Wang, Yongjie
    Liu, Dandan
    Zhang, Shujing
    Wang, Jiaxin
    Zhao, Long
    Xing, Xin
    Li, Junjie
    Xiao, Yusheng
    Wang, Jun
    Zhi, Minjie
    Wang, Peng
    Huang, Jing
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2023, 68 (08): : 2136 - 2145
  • [7] Solubility of Perindopril <sc>l</sc>-Arginine in 10 Pure Solvents and 3 Binary Solvents from 278.15 to 323.15 K
    Cao, Hongchen
    Xiao, Yuntian
    Liu, Yongkang
    Zhou, Ling
    Yin, Qiuxiang
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2024, 69 (11): : 4206 - 4215
  • [8] Solubility and Data Correlation of Isoniazid in Different Pure and Binary Mixed Solvent Systems from 283.15 K to 323.15 K
    Gong, Tingting
    Han, Dandan
    Chen, Yifu
    Wang, Shuo
    Tang, Weiwei
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2018, 63 (12): : 4767 - 4778
  • [9] Solubility and Hansen Solubility Parameters of L-Glutamic Acid 5-Methyl Ester in 12 Organic Solvents from 283.15 to 323.15 K
    He, Hui
    Qu, Jingxuan
    Huang, Haishuang
    Guo, Ying
    Hu, Shen
    Zhao, Yue
    Wang, Yongjie
    Wang, Peng
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2021, 66 (10): : 3844 - 3852
  • [10] Determination and Correlation of Solubility of Metformin Hydrochloride in Aqueous Binary Solvents from 283.15 to 323.15 K
    Yu, Chuanping
    Sun, Xinyuan
    Wang, Yan
    Du, Shichao
    Shu, Liang
    Sun, Qilei
    Xue, Fumin
    ACS OMEGA, 2022, 7 (10): : 8591 - 8600