Liquefaction and filling of liquid methane and oxygen bipropellant in a common bulkhead tank equipped with a zero boil-off system

被引:1
|
作者
Zhang, Wujie [1 ]
Zhang, Hao [2 ]
Wang, Bin [2 ]
Jiang, Wenbing [2 ]
Miao, Ruijiao [1 ]
Huang, Yonghua [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
[2] Shanghai Inst Aerosp Syst Engn, Shanghai 201108, Peoples R China
关键词
LOX/LCH; 4; bipropellant; Cryogenic; Common bulkhead tank; Transient thermodynamic characteristics; Liquefaction; Filling; Zero boil-off; DENSITY MULTILAYER INSULATION; OPTIMIZATION; DESIGN; SHIELD; STAGE;
D O I
10.1016/j.cryogenics.2024.103943
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental setup incorporating a tank with a non-insulated common bulkhead inside and a zero-boil-off system outside was designed and established to investigate the transient thermodynamic characteristics of bipropellant liquid oxygen and methane during liquefaction, filling, and zero-boil-off storage processes. The results demonstrate the advantage of the non-insulated common bulkhead tank in storing liquid oxygen and liquid methane. The non-insulated common bulkhead provided an additional heat transfer pathway, allowing the cold energy released by liquid oxygen to be used to improve the cooling rate of methane and stabilize its storage state during the liquefaction and filling processes. Furthermore, the influence of the operational modes of the zero-boil-off system on the storage states of the fluids was examined. The cooling power delivered by the zeroboil-off system was identified as the most critical factor affecting the storage state of the fluids in the common bulkhead tank. In the absence of cooling power, the temperature rising rates in the liquid oxygen and liquid methane compartments were 4.3 K/h and 4.4 K/h, respectively. Compared with the results during the helium circulator standby stage, the pressure difference between the two compartments increased by 62.73 % in the absence of cooling power. The findings indicate the necessity of maintaining adequate cooling power to achieve stable zero boil-off storage, providing guidelines for the design and operation of practical liquid oxygen-liquid methane common bulkhead storage tanks with zero boil-off requirements.
引用
收藏
页数:12
相关论文
共 12 条
  • [1] Experimental study on the liquid hydrogen zero boil-off in a liquefaction system with an automatic control technology
    Ha, Dong Woo
    Noh, Hyun Woo
    Koo, Tae Hyung
    Ko, Rock Kil
    Seo, Young Min
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 83 : 933 - 945
  • [2] Development of a Superconducting Magnet System with Zero Liquid Helium Boil-off
    Zhang, Xuelei
    Ren, Yong
    Wang, Futang
    Chen, Wenge
    Chen, Zhiyou
    JOURNAL OF SUPERCONDUCTIVITY AND NOVEL MAGNETISM, 2014, 27 (04) : 1027 - 1030
  • [3] Development of a Superconducting Magnet System with Zero Liquid Helium Boil-off
    Xuelei Zhang
    Yong Ren
    Futang Wang
    Wenge Chen
    Zhiyou Chen
    Journal of Superconductivity and Novel Magnetism, 2014, 27 : 1027 - 1030
  • [4] The Thermal Uniformity Performance Analysis of the Cold Shield in the LOX/LCH4 Common Bulkhead and Zero Boil-off Storage System
    Zhang, Wujie
    Xu, Anyi
    Jiang, Wenbin
    Sun, Peijie
    Li, Peng
    Miao, Ruijiao
    Huang, Yonghua
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2024, 45 (08): : 2215 - 2222
  • [5] Assessment of Boil-Off Losses and Their Cost Implication during Liquid Hydrogen Tank Filling with and without Precooling
    Okpeke, Bright Ebikemefa
    Aider, Cherif Ait
    Baetcke, Lars
    Ehlers, Soeren
    ENERGIES, 2024, 17 (16)
  • [6] Operating characteristics study on small liquid nitrogen Zero boil-off system
    Zhang, Yang-Yang
    Zhao, Ya-Nan
    Yan, Tao
    Hong, Guo-Tong
    Li, Yang
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2015, 36 (12): : 2543 - 2546
  • [7] Self-pressurization behavior and zero boil-off feasibility of LOX/LCH4 pair stored in a single-layer metal common bulkhead tank
    Zhang, Wujie
    Wang, Bin
    Zhang, Hao
    Jiang, Wenbing
    Miao, Ruijiao
    Xu, Anyi
    Li, Peng
    Sun, Peijie
    Huang, Yonghua
    ENERGY, 2024, 312
  • [8] Development of a large volume zero boil-off liquid xenon storage system for muon rare decay experiment (MEG)
    Iwamoto, T.
    Sawada, R.
    Haruyama, T.
    Mihara, S.
    Doke, T.
    Hisamatsu, Y.
    Kasami, K.
    Maki, A.
    Mori, T.
    Natori, H.
    Nishiguchi, H.
    Nishimura, Y.
    Ootani, W.
    Terasawa, K.
    Uchiyama, Y.
    Yamada, S.
    CRYOGENICS, 2009, 49 (06) : 254 - 258
  • [9] Experimental and numerical investigation of change in boil-off gas and thermodynamic characteristics according to filling ratio in a C-type cryogenic liquid fuel tank
    Jeon, Gyu-Mok
    Park, Jong-Chun
    Kim, Jae-Won
    Lee, Young-Bum
    Kim, Deok-Su
    Kang, Dong-Eok
    Lee, Sang-Beom
    Lee, Sang-Won
    Ryu, Min-Cheol
    ENERGY, 2022, 255
  • [10] Thermal Efficiency and Economics of a Boil-Off Hydrogen Re-Liquefaction System Considering the Energy Efficiency Design Index for Liquid Hydrogen Carriers
    Choi, Minsoo
    Jung, Wongwan
    Lee, Sanghyuk
    Joung, Taehwan
    Chang, Daejun
    ENERGIES, 2021, 14 (15)