Study on performance optimization of a liquid desiccant air conditioning system driven by photovoltaic thermal-air source heat pump

被引:0
|
作者
Guo, Chunmei [1 ]
Bai, Ruxue [1 ]
Gao, Rong [1 ]
Li, Yu [1 ]
Xiong, Hang [1 ]
He, Zhonglu [1 ]
You, Yuwen [1 ]
Wang, Leilei [2 ,3 ]
机构
[1] Tianjin Chengjian Univ, Sch Energy & Safety Engn, Tianjin 300384, Peoples R China
[2] Tianjin Key Lab Green Bldg & Low Carbon Technol, Tianjin 300161, Peoples R China
[3] Tianjin Bldg Sci Energy Efficiency Co Ltd, Tianjin 300171, Peoples R China
关键词
INDIRECT EVAPORATIVE COOLER; COOLING SYSTEM; ENERGY; DEHUMIDIFICATION; SIMULATION; STORAGE;
D O I
10.1063/5.0220870
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Compared to conventional condensation dehumidification systems, a solar liquid desiccant air conditioning system (SLDAC) offers distinct advantages, enabling independent control of temperature and humidity while operating at low carbon levels. This paper proposes a low-carbon SLDAC thermal mass exchange model that uses an indirect evaporative cooling liquid dehumidifier and photovoltaic thermal and air source heat pump for combined driving of the solution regeneration process. The system simulation model was created using MATLAB and TRNSYS software. An experimental comparison was conducted between the dehumidification module and the regeneration module, and the system's performance was simulated with an airflow of 150 m3/h in the Tianjin area. The results indicate an average dehumidification efficiency of 44.03% and a regeneration efficiency of 40.80% throughout the cooling season. During the cooling season, the power generation of the system met the power demand and produced a surplus of 85.36 kWh, achieving overall self-sufficiency in power consumption. The optimized system's operating parameters were proposed, with regeneration temperatures of 57 degrees C in June and September and 65 degrees C in July and August. During the cooling season, the system's regeneration capacity exceeded its dehumidification capacity for 84.90% of the operating time. As a result of optimization, the system's carbon emissions were reduced by 59.35%.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Optimization of solution concentration in liquid desiccant air-conditioning system driven by heat pump
    Guan, Bowen
    Liu, Xiaohua
    Zhang, Tao
    [J]. ENERGY AND BUILDINGS, 2020, 225
  • [2] Experimental study on the performance of a photovoltaic/thermal-air dual heat source direct-expansion heat pump
    Du, Boyao
    Quan, Zhenhua
    Hou, Longshu
    Zhao, Yaohua
    Lou, Xiaoying
    Wang, Chunqing
    [J]. APPLIED THERMAL ENGINEERING, 2021, 188
  • [3] Simulation analysis of a photovoltaic/thermal-air dual heat source direct-expansion heat pump
    Du, Boyao
    Quan, Zhenhua
    Hou, Longshu
    Zhao, Yaohua
    Lou, Xiaoying
    Shao, Sibo
    [J]. RENEWABLE ENERGY, 2023, 218
  • [4] Dynamic model and response characteristics of liquid desiccant air-conditioning system driven by heat pump
    Guan, Bowen
    Liu, Xiaohua
    Zhang, Tao
    Wang, Andong
    [J]. BUILDING SIMULATION, 2021, 14 (06) : 1773 - 1784
  • [5] Dynamic model and response characteristics of liquid desiccant air-conditioning system driven by heat pump
    Bowen Guan
    Xiaohua Liu
    Tao Zhang
    Andong Wang
    [J]. Building Simulation, 2021, 14 : 1773 - 1784
  • [6] Optimization of solar and heat pump complementary powered desiccant air conditioning system
    Chen, Chuang
    Yang, Huaqiu
    Li, Xin
    Chen, Liu
    Shi, Meng
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 87
  • [7] Thermal performance of a novel air conditioning system using a liquid desiccant
    Oliveira, AC
    Afonso, CF
    Riffat, SB
    Doherty, PS
    [J]. APPLIED THERMAL ENGINEERING, 2000, 20 (13) : 1213 - 1223
  • [10] Field Study on Humidification Performance of a Desiccant Air-Conditioning System Combined with a Heat Pump
    Kawamoto, Koichi
    Cho, Wanghee
    Kohno, Hitoshi
    Koganei, Makoto
    Ooka, Ryozo
    Kato, Shinsuke
    [J]. ENERGIES, 2016, 9 (02):