Estimation of the Proton Resonance Frequency Coefficient in Agar-based Phantoms

被引:0
|
作者
Filippou, Antria [1 ]
Evripidou, Nikolas [1 ]
Georgiou, Andreas [1 ]
Nikolaou, Anastasia [1 ]
Damianou, Christakis [1 ]
机构
[1] Cyprus Univ Technol, Dept Elect Engn Comp Engn & Informat, 30 Archbishop Kyprianou St, CY-3036 Limassol, Cyprus
关键词
Agar; magnetic resonance imaging; phantoms; silicon dioxide; thermometry; ultrasound; TISSUE-MIMICKING PHANTOM; IN-VIVO; FOCUSED ULTRASOUND; MR THERMOMETRY; THERMAL LESIONS; RABBIT BRAIN; SHIFT METHOD; GEL PHANTOM; POLYACRYLAMIDE; THERMOTHERAPY;
D O I
10.4103/jmp.jmp_146_23
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: Agar-based phantoms are popular in high intensity focused ultrasound (HIFU) studies, with magnetic resonance imaging (MRI) preferred for guidance since it provides temperature monitoring by proton resonance frequency (PRF) shift magnetic resonance (MR) thermometry. MR thermometry monitoring depends on several factors, thus, herein, the PRF coefficient of agar phantoms was estimated.Materials and Methods: Seven phantoms were developed with varied agar (2, 4, or 6% w/v) or constant agar (6% w/v) and varied silica concentrations (2, 4, 6, or 8% w/v) to assess the effect of the concentration on the PRF coefficient. Each phantom was sonicated using varied acoustical power for a 30 s duration in both a laboratory setting and inside a 3T MRI scanner. PRF coefficients were estimated through linear trends between phase shift acquired using gradient sequences and thermocouple-based temperatures changes.Results: Linear regression (R 2 = 0.9707-0.9991) demonstrated a proportional dependency of phase shift with temperature change, resulting in PRF coefficients between -0.00336 +/- 0.00029 and -0.00934 +/- 0.00050 ppm/degrees C for the various phantom recipes. Weak negative linear correlations of the PRF coefficient were observed with increased agar. With silica concentrations, the negative linear correlation was strong. For all phantoms, calibrated PRF coefficients resulted in 1.01-3.01-fold higher temperature changes compared to the values calculated using a literature PRF coefficient.Conclusions: Phantoms developed with a 6% w/v agar concentration and doped with 0%-8% w/v silica best resemble tissue PRF coefficients and should be preferred in HIFU studies. The estimated PRF coefficients can result in enhanced MR thermometry monitoring and evaluation of HIFU protocols.
引用
收藏
页码:167 / 180
页数:14
相关论文
共 50 条
  • [1] Agar-based phantoms for skin diagnostic imaging
    Kuzmina, Ilona
    Lukinsone, Vanesa
    Rubins, Uldis
    Osina, Ilze
    Dambite, Laura
    Maslobojeva, Anna
    Spigulis, Janis
    TISSUE OPTICS AND PHOTONICS, 2020, 11363
  • [2] MR relaxation times of agar-based tissue-mimicking phantoms
    Antoniou, Anastasia
    Georgiou, Leonidas
    Christodoulou, Theodora
    Panayiotou, Natalie
    Ioannides, Cleanthis
    Zamboglou, Nikolaos
    Damianou, Christakis
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (05):
  • [3] Characterization of the concentration of agar-based soft tissue mimicking phantoms by impact analysis
    Poudrel, Anne-Sophie
    Bouffandeau, Arthur
    Le Demeet, Oriane
    Rosi, Giuseppe
    Nguyen, Vu-Hieu
    Haiat, Guillaume
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 152
  • [4] Soft tissue characterization by dynamic impact analysis: Results on agar-based phantoms
    Poudrel, Anne-Sophie
    Bouffandeau, Arthur
    Rosi, Giuseppe
    Nguyen, Vu-Hieu
    Haiat, Guillaume
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03):
  • [5] Evaluation of ultrasonic scattering in agar-based phantoms using 3D printed scattering molds
    Antria Filippou
    Christakis Damianou
    Journal of Ultrasound, 2022, 25 : 597 - 609
  • [6] Biological tissue-equivalent agar-based solid phantoms and SAR estimation using the thermographic method in the range of 3-6 GHz
    Onishi, T
    Ishido, R
    Takimoto, T
    Saito, K
    Uebayashi, S
    Takahashi, M
    Ito, K
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2005, E88B (09) : 3733 - 3741
  • [7] Sensing with agar-based optical waveguides
    Fujiwaraa, Eric
    Cordeirob, Cristiano M. B.
    Okuc, Hiromasa
    Suzukia, Carlos K.
    SPIE FUTURE SENSING TECHNOLOGIES 2023, 2023, 12327
  • [8] Agar-Based Adaptable DIY Materials
    Zuberi, Hajra S.
    Bengisu, Murat
    FME TRANSACTIONS, 2019, 47 (03): : 442 - 451
  • [9] Evaluation of ultrasonic scattering in agar-based phantoms using 3D printed scattering molds
    Filippou, Antria
    Damianou, Christakis
    JOURNAL OF ULTRASOUND, 2022, 25 (03) : 597 - 609
  • [10] Bacto agar-based gel polymer electrolyte
    Jeremy C. H. Koh
    Zainal Arifin Ahmad
    Ahmad Azmin Mohamad
    Ionics, 2012, 18 : 359 - 364