Seismic retrofitting of masonry infilled RC buildings in low-to moderate-seismic regions: case study of typical Sri Lankan school buildings

被引:0
|
作者
Sathurshan, Mathavanayakam [1 ]
Thamboo, Julian [2 ]
Rossetto, Tiziana [3 ]
Wijesundara, Kushan [4 ]
Mallikarachchi, Chinthaka [1 ]
Cels, Jonas [3 ]
Baiguera, Marco [5 ]
Zoppo, Marta Del [3 ,6 ]
Dias, Priyan [7 ]
机构
[1] Univ Moratuwa, Dept Civil Engn, Moratuwa, Sri Lanka
[2] South Eastern Univ Sri Lanka, Dept Civil Engn, Oluvil, Sri Lanka
[3] UCL, EPICtr, London, England
[4] Univ Peradeniya, Dept Civil Engn, Kandy, Sri Lanka
[5] Global Earthquake Model Fdn, Pavia, Italy
[6] Univ Naples Federico II, Dept Struct Engn & Architecture, Naples, Italy
[7] Sri Lanka Inst Informat Technol, Malabe, Sri Lanka
关键词
Reinforced concrete buildings; Retrofitting; Seismic vulnerability; Masonry infills; RC jacketing; Shear failure; Multi-criteria decision making (MCDM); MULTICRITERIA DECISION-MAKING; SHEAR FAILURE; FRAGILITY; FRAMES; RESILIENCE;
D O I
10.1007/s10518-024-02010-y
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Seismic retrofitting solutions for reinforced concrete (RC) school building types in high-seismic regions are extensively reported in the state-of-the-art. Conversely, limited studies have focused on the extent of retrofitting needed for RC school buildings in low- to moderate-seismic regions. To explore this aspect, seismic retrofitting options for RC school buildings in Sri Lanka are investigated. Three retrofitting options are examined: (1) adding/altering masonry infill walls (MI walls) to reduce irregularity in buildings, (2) RC jacketing of columns and (3) a combination of adding/altering MI walls and RC jacketing. These retrofit options are applied to a common typology of Sri Lankan MI-RC school buildings, considering two and three storey height variations. A simplified numerical modelling approach that accounts for the contribution of MIs, the shear failure of RC column and torsional effects is adopted to analyse the performance of the school buildings with and without retrofit. Based on the analyses, three damage states are defined: damage limitation (DL), significant damage (SD) and near collapse (NC). Finally, a multi-criteria decision making (MCDM) method is used to determine the optimal retrofitting option for the considered school building typology, considering engineering and economic parameters. The optimal retrofit solution for the three-storey MI-RC school building is found to be jacketing of ground floor columns. Conversely, for the two-storey MI-RC school building, alteration of infill walls (MI walls) is deemed optimal. Finally, a sensitivity analysis is carried out on the MCDM method.
引用
收藏
页码:6447 / 6471
页数:25
相关论文
共 50 条
  • [1] Rapid seismic visual screen method for masonry infilled reinforced concrete framed buildings: Application to typical Sri Lankan school buildings
    Sathurshan, Mathavanayakam
    Thamboo, Julian
    Mallikarachchi, Chinthaka
    Wijesundara, Kushan
    Dias, Priyan
    [J]. INTERNATIONAL JOURNAL OF DISASTER RISK REDUCTION, 2023, 92
  • [2] Seismic Retrofitting of Historic Masonry Buildings - Case Study
    Santhakumar, A. R.
    Mathews, M. S.
    Thirumurugan, S.
    Uma, Rao
    [J]. 7TH INTERNATIONAL CONFERENCE ON STRUCTURAL ANALYSIS OF HISTORIC CONSTRUCTIONS: STRENGTHENING AND RETROFITTING, PTS 1 AND 2, 2010, 133-134 : 991 - 996
  • [3] Seismic Retrofitting of Irregular Mixed Masonry-RC Buildings: Case Study in Lisbon
    Rodrigues, Joao
    Ilic, Jelena Milosevic
    Bento, Rita
    [J]. SEISMIC BEHAVIOUR AND DESIGN OF IRREGULAR AND COMPLEX CIVIL STRUCTURES IV, 2022, 50 : 163 - 175
  • [4] Seismic retrofitting of low strength unreinforced masonry non-engineered school buildings
    Bothara, J.K.
    Pandey, B.
    Guragain, R.
    [J]. Bulletin of the New Zealand Society for Earthquake Engineering, 2004, 37 (01): : 13 - 22
  • [5] Effective seismic retrofitting concept for existing car park buildings in moderate seismic regions
    Terehovich, Vladislav
    Balaskas, Georgios
    Don, Rafaela
    Hoffmeister, Benno
    [J]. ce/papers, 2023, 6 (3-4) : 2260 - 2265
  • [6] SEISMIC RETROFITTING OF CONFINED MASONRY-RC BUILDINGS: THE CASE STUDY OF THE UNIVERSITY HALL OF RESIDENCE IN MESSINA, ITALY
    De Domenico, Dario
    Impollonia, Nicola
    Ricciardi, Giuseppe
    [J]. INGEGNERIA SISMICA, 2019, 36 (01): : 54 - 85
  • [7] Seismic Analysis and Retrofitting by Steelwork of Existing Precast RC Buildings: A Case Study
    Formisano, Antonio
    Davino, Antonio
    [J]. INTERNATIONAL CONFERENCE ON NUMERICAL ANALYSIS AND APPLIED MATHEMATICS ICNAAM 2019, 2020, 2293
  • [8] Seismic risk reduction through retrofitting of school masonry buildings from Romania
    Scupin, Alexandra
    Vacareanu, Radu
    [J]. FRONTIERS IN BUILT ENVIRONMENT, 2023, 8
  • [9] A Pushover Seismic Analysis and Retrofitting Method Applied to Low-Rise RC School Buildings
    Hsiao, Fu-Pei
    Oktavianus, Yusak
    Ou, Yu-Chen
    Luu, Cong-Hieu
    Hwang, Shyh-Jiann
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (03) : 311 - 324
  • [10] Evaluation of seismic hazard in low to moderate seismic regions, Sri Lankaa case study
    Gamage, Prasanna
    Venkatesan, Srikanth
    [J]. JOURNAL OF SEISMOLOGY, 2019, 23 (03) : 579 - 611