Agreement of lymphocyte subsets detection permits reference intervals transference between flow cytometry systems: direct validation using established reference intervals

被引:0
|
作者
Liu, Mei [1 ]
Yu, Sihua [1 ,2 ,3 ]
Li, Siyao [1 ]
Yu, Xiaowen [1 ]
Wang, Heqiao [1 ,2 ,3 ]
Wang, Jiaqi [1 ,2 ,3 ]
Wang, Pan [2 ,3 ]
Su, Zihan [1 ]
Fu, Yajing [1 ,2 ,3 ]
Jiang, Yongjun [1 ,2 ,3 ]
Zhao, Min [1 ,4 ]
Zhang, Zining [1 ,2 ,3 ,4 ]
Shang, Hong [1 ,2 ,3 ,4 ]
机构
[1] China Med Univ, Hosp 1, Natl Clin Res Ctr Lab Med, Shenyang 110001, Liaoning, Peoples R China
[2] China Med Univ, Hosp 1, Natl Clin Res Ctr Lab Med, NHC Key Lab AIDS Prevent Treatment,State Key Lab D, Shenyang, Peoples R China
[3] Chinese Acad Med Sci, Key Lab AIDS Immunol, Shenyang, Peoples R China
[4] China Med Univ, Hosp 1, Natl Clin Res Ctr Lab Med, Dept Lab Med, Shenyang 110001, Liaoning, Peoples R China
关键词
lymphocyte subsets; flow cytometry; reference intervals; transference; PEDIATRIC REFERENCE INTERVALS; CLSI-BASED TRANSFERENCE; CALIPER DATABASE; BECKMAN; ASSAYS; HIV; PERFORMANCE;
D O I
10.1515/cclm-2024-0603
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives With the increasing demand and application of lymphocyte subsets detection in clinical laboratories, different single-platform flow cytometer (FCM) systems have been developed. There is an urgent need to establish the reference intervals (RIs) for different single-platform FCMs and transferring them from one FCM system to another provides a much more feasible and convenient approach. This study aimed to explore the transferability of RIs for lymphocyte subsets across different flow cytometry platforms.Methods We first conducted the pairwise method comparison across four FCM platforms, including NovoCyte, BriCyteE6, DxFLEX, and FACSCantoII systems. Next, the transferability of RIs of lymphocyte subsets was evaluated. Furthermore, we conducted the RIs transference based on the FACSCantoII system, BriCyteE6 system and DxFLEX system, except for NK cells. The transferred RIs were further verified by calculating the bias (CV) between the established ones.Results The results of lymphocyte subsets detection based on the NovoCyte, BriCyteE6, DxFLEX, and FACSCantoII systems were comparable and it was feasible to transfer the RIs of lymphocyte subsets detected by the four FCM systems. The RIs of lymphocyte subsets detection using FACSCantoII, DxFLEX, and BriCyteE6 systems were established. Upon transferring the RIs of lymphocyte subsets from the FACSCantoII system to the BriCyteE6 system, and DxFLEX system except for NK cells, the CV between the transferred RIs and the established ones was below 20 % for all parameters.Conclusions The present study illustrated that the RIs of lymphocyte subsets could be transferred across different flow cytometry systems except for NK cells with different definition strategies.
引用
收藏
页码:387 / 398
页数:12
相关论文
共 10 条
  • [1] REFERENCE INTERVALS OF PLATELET ACTIVATION ASSAY USING FLOW CYTOMETRY
    Zolotova, Ekaterina
    Zhilenkova, Yulia
    Kim, Elizaveta
    Mirolyubova, Yulia
    Vavilova, Tatiana
    Sirotkina, Olga
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 : 211 - 211
  • [2] Reference intervals for leukocyte subsets in adults: Results from a population-based study using 10-color flow cytometry
    Melzer, Susanne
    Zachariae, Silke
    Bocsi, Jozsef
    Engel, Christoph
    Loeffler, Markus
    Tarnok, Attila
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2015, 88 (04) : 270 - 281
  • [3] Agreement of LC-MS assays for IGF-1 traceable to NIST and WHO standards permits harmonization of reference intervals between laboratories
    Ezra, Sally
    Winstone, Tara M. L.
    Singh, R.
    Orton, Dennis J.
    CLINICAL BIOCHEMISTRY, 2023, 116 : 75 - 78
  • [4] Reference Intervals and Comparative Analysis of Reticulocyte Counts Using the Mindray BC-6200, Flow Cytometry, and Manual Microscopy
    Aphaiwiwat, Hathaiphon
    Ketloy, Chutitorn
    Thepnarin, Tapakorn
    Watanaboonyongcharoen, Phandee
    Prompetchara, Eakachai
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2025,
  • [5] CLSI-based transference of the CALIPER database of pediatric reference intervals from Abbott to Beckman, Ortho, Roche and Siemens Clinical Chemistry Assays: Direct validation using reference samples from the CALIPER cohort
    Estey, Mathew P.
    Cohen, Ashley H.
    Colantonio, David A.
    Chan, Man Khun
    Marvasti, Tina Binesh
    Randell, Edward
    Delvin, Edgard
    Cousineau, Jocelyne
    Grey, Vijaylaxmi
    Greenway, Donald
    Meng, Qing H.
    Jung, Benjamin
    Bhuiyan, Jalaluddin
    Seccombe, David
    Adeli, Khosrow
    CLINICAL BIOCHEMISTRY, 2013, 46 (13-14) : 1197 - 1219
  • [6] Determination of laboratory reference ranges for lymphocyte immunopheno-type subsets in healthy adult Japanese using flow cytometry
    Webster, HK
    Kawai, Y
    Haney, D
    Nakahara, K
    Watanabe, K
    Ogawa, E
    Miller, L
    Buchner, L
    Lock, M
    Thompson, P
    ASIAN PACIFIC JOURNAL OF ALLERGY AND IMMUNOLOGY, 2003, 21 (03): : 161 - 169
  • [7] Establishing Age-Gender Specific Reference Values of T and B Lymphocyte Subsets in Healthy Adults Using Flow Cytometry
    Kaynak, Fatma Turgut
    Yanasik, Melek
    Cinar, Suzan
    Besisik, Sevgi Kalayoglu
    Deniz, Gunnur
    Gelmez, Metin Yusuf
    EXPERIMED, 2025,
  • [8] CLSI-based transference of the CALIPER database of pediatric reference intervals from Abbott to Beckman, Ortho, Roche and Siemens Clinical Chemistry Systems: Direct validation using reference samples from the CALIPER cohort (vol 46, pg 1197, 2013)
    Estey, Mathew P.
    Cohen, Ashley H.
    Colantonio, David A.
    Chan, Man Khun
    Marvasti, Tina Binesh
    Randell, Edward
    Delvin, Edgard
    Cousineau, Jocelyne
    Grey, Vijaylaxmi
    Greenway, Donald
    Meng, Qing H.
    Jung, Benjamin
    Bhuiyan, Jalaluddin
    Seccombe, David
    Adeli, Khosrow
    CLINICAL BIOCHEMISTRY, 2013, 46 (18) : 1916 - 1916
  • [9] Total protein measurement in canine cerebrospinal fluid: agreement between a turbidimetric assay and 2 dye-binding methods and determination of reference intervals using an indirect a posteriori method
    Riond, B.
    Steffen, F.
    Schmied, O.
    Hofmann-Lehmann, R.
    Lutz, H.
    VETERINARY CLINICAL PATHOLOGY, 2014, 43 (01) : 78 - 88
  • [10] Establishment of reference intervals for plasma IL-2, IL-4, IL-5, and IL-17A in healthy adults from the Jiangsu region of eastern China using flow cytometry: A single-center study
    Liu, Qian
    Xia, Zhengping
    Huang, Tingting
    Yang, Fang
    Wang, Xizhen
    Yang, Fumeng
    CYTOKINE, 2024, 179