Finite element analysis of anterior cruciate ligament reconstruction techniques: A comparison of the mechanical properties of all-inside fixation and traditional fixation

被引:0
|
作者
Chen, Xiaodong [1 ]
Xue, Changguo [2 ]
Li, Kuanxin [1 ]
Mu, Kecheng [1 ]
Yao, Cheng [3 ]
Wang, Zhiyan [1 ]
Chen, Hongzhi [4 ]
Zhang, Jun [5 ]
机构
[1] Bengbu Med Univ, Affiliated Hosp 1, Dept Orthoped, Anhui Key Lab Tissue Transformat, Bengbu, Anhui, Peoples R China
[2] Anhui Univ Sci & Technol, Sch Mat Sci & Engn, Huainan, Peoples R China
[3] Third Peoples Hosp Bengbu, Dept Orthoped, Bengbu, Anhui, Peoples R China
[4] Bengbu Med Univ, Affiliated Hosp 1, Dept Radiol, Bengbu, Anhui, Peoples R China
[5] First Peoples Hosp Bengbu, Dept Orthoped, Bengbu, Peoples R China
关键词
anterior cruciate ligament reconstruction; all-inside fixation technique; traditional fixation technique; finite element analysis; knee; GRAFT-TUNNEL INTERACTION; SEMITENDINOSUS;
D O I
10.3389/fbioe.2024.1438839
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective The main purpose of this study was to explore the mechanical properties of the anterior cruciate ligament and its attachments following reconstruction with the all-inside technique after anterior cruciate ligament injury.Methods Knee joint computed tomography data were collected from healthy volunteers, and knee joint models were created using Mimics software. A normal knee joint model, an all-inside reconstructed anterior cruciate ligament model, and a traditional reconstructed anterior cruciate ligament model were established. A tensile force of 134 N and a bending moment of 5 N/m were applied at the anterior aspect of the proximal tibia in these three models. The knee joint was subjected to external rotation, internal rotation, varus, valgus, flexion, and extension under this bending moment. The magnitude and distribution of stress on the ligament or graft and the magnitude and distribution of stress on the graft attachments were observed under different loading conditions.Results Under different external forces, the maximum stress on the ligament in the normal model fluctuated from 1.949 to 18.302 MPa, with an uncertain distribution of maximum stress. The maximum stress on the graft in the all-inside reconstructed anterior cruciate ligament model fluctuated from 0.705 to 3.465 MPa and was mainly distributed at the junction of the graft and the tibial footprint. In the traditional reconstructed anterior cruciate ligament model, the maximum stress on the graft fluctuated from 5.012 to 59.269 MPa and was primarily distributed at the junction of the interference screw and the graft. The concentration of stress on the loop and plate in the all-inside reconstructed anterior cruciate ligament model fluctuated from 70.461 to 346.363 MPa, with maximum stress distributed at the junction of the loop and the tibial surface. The maximum stress on the interference screw in the traditional reconstructed anterior cruciate ligament model fluctuated from 10.184 to 92.298 MPa, with maximum stress primarily distributed at the end of the interference screw.Conclusion Under different external forces, the graft used in all-inside anterior cruciate ligament reconstruction is subjected to fewer external forces than that used in traditional anterior cruciate ligament reconstruction, which may indicate a relatively stable mechanical environment. The strength of the loop and plate can theoretically tolerate daily knee joint movements of patients without injury.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] CLINICAL AND FUNCTIONAL COMPARISON OF TWO DIFFERENT FIXATION TECHNIQUES IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION: ALL-INSIDE VERSUS ANTEROMEDIAL
    Polat, Gokhan
    Bayram, Serkan
    Kilicoglu, Onder Ismet
    ACTA ORTOPEDICA BRASILEIRA, 2023, 31 (06):
  • [2] Reconstruction of the anterior cruciate ligament:: comparison of outside-in and all-inside techniques
    Brandsson, S
    Faxén, E
    Eriksson, BI
    Swärd, L
    Lundin, O
    Karlsson, J
    BRITISH JOURNAL OF SPORTS MEDICINE, 1999, 33 (01) : 42 - 45
  • [3] Editorial Commentary: All-Inside Anterior Cruciate Ligament Reconstruction: In Pursuit of Ideal Graft Fixation
    Geeslin, Andrew G.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (03): : 919 - 920
  • [4] All-Inside Anterior Cruciate Ligament Reconstruction
    Blackman, Andrew J.
    Stuart, Michael J.
    JOURNAL OF KNEE SURGERY, 2014, 27 (05) : 347 - 352
  • [5] All-Inside Anterior Cruciate Ligament Reconstruction
    Nuelle, Clayton W.
    Balldin, B. Christian
    Slone, Harris S.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2022, 38 (08): : 2368 - 2369
  • [6] Anterior Cruciate Ligament Reconstruction: All-Inside Reconstruction
    Lynch, Jamie L.
    Anderson, Kyle
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2013, 21 (01) : 40 - 46
  • [7] Comparative study of the clinical efficacy of all-inside and traditional techniques in anterior cruciate ligament reconstruction
    An, Bai-Jing
    Wang, Yao-Ting
    Zhao, Zhe
    Wang, Ming-Xin
    Xing, Geng-Yan
    WORLD JOURNAL OF CLINICAL CASES, 2023, 11 (14) : 3195 - 3203
  • [8] Biomechanical Comparison of Graft Preparation Techniques for All-Inside Anterior Cruciate Ligament Reconstruction
    Bowes, Julia
    Mohamed, Nada
    Baptiste, Jonelle Jn
    Westover, Lindsey
    Hui, Catherine
    Sommerfeldt, Mark
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2020, 8 (07)
  • [9] Comparative study of the clinical efficacy of all-inside and traditional techniques in anterior cruciate ligament reconstruction
    Bai-Jing An
    Yao-Ting Wang
    Zhe Zhao
    Ming-Xin Wang
    Geng-Yan Xing
    World Journal of Clinical Cases, 2023, (14) : 3195 - 3203
  • [10] Anterior Cruciate Ligament Reconstruction: Fixation Techniques
    McDermott, Emily R.
    Aman, Zachary S.
    Dekker, Travis J.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2024, 40 (02): : 201 - 203