Validation of finite-element-simulated orthodontic forces produced by thermoplastic aligners: Effect of aligner geometry and creep

被引:0
|
作者
Ye, N. [1 ,3 ]
Brown, B. E. [2 ]
Mantell, S. C. [1 ]
Larson, B. E. [2 ]
Gruenheid, T. [2 ]
Fok, A. S. [3 ]
机构
[1] Univ Minnesota, Dept Mech Engn, Minneapolis, MN USA
[2] Univ Minnesota, Sch Dent, Minneapolis, MN USA
[3] Univ Minnesota, Minnesota Dent Res Ctr Biomat & Biomech, Minneapolis, MN USA
关键词
TOOTH MOVEMENT; MANUFACTURING TECHNOLOGY; MAGNITUDE;
D O I
10.1016/j.jmbbm.2024.106755
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: Finite element (FE) models for determining the orthodontic forces delivered by clear aligners often lack validation. The aim of this study was to develop and validate accurate FE models for clear aligners, considering the small but important geometrical variations from the thermoforming process and the creep behavior of the aligner material. Methods and materials: The tooth misalignment considered was a 2.4 degrees torque aberration (rotation about the mesial-distal axis at the level of the center of resistance) of the maxillary left central incisor. FE models were created from Micro-CT scans of a model dental arch and five nominally identical aligners with the aforementioned misfit. Fitting of the aligners onto the dental arch was simulated using Abaqus's Interference Fit function, followed by surface-to-surface frictional interaction. Stress relaxation of the aligner material was measured using double-cantilever beam bending and modeled with a Prony series. The assembled FE models were validated by comparing the predicted forces and moments delivered to the maxillary left central incisor with experimental data, obtained with a custom-built but fully calibrated apparatus. Results: Good agreement between prediction and measurement was obtained for both the short- and long-term forces and moments. In the short-term, i.e., after 30 s, the dominant force in the labial-lingual direction had a maximum difference of 2.9% between experiment and simulation, and the dominant moment about the mesial-distal axis had a maximum difference of 8.3%. In the long-term, i.e., after 4 h, the experimental and numerical forces had a maximum difference of 8.4%. There were statistically significant differences in the forces delivered among the nominally identical aligners, which were predicted by the geometrically accurate FE models and attributed to the variations in the points of contact between the aligners and the dental arch. The decay in force applied was affected by both the viscoelastic material behavior and friction between the aligner and arch. Conclusion: For accurate prediction of the forces and moments delivered by thermoplastic aligners, FE models that can accurately capture the point contacts between the aligners and the underlying teeth are essential. Stress relaxation of the aligners could be adequately modeled using the Prony series to represent the temporal changes of their elastic modulus.
引用
收藏
页数:11
相关论文
共 12 条
  • [1] Validation of finite element models for orthodontic aligners
    Ye, N.
    Brown, B. E.
    Mantell, S. C.
    Heo, Y. C.
    Larson, B. E.
    Fok, A. S.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 134
  • [2] ORTHODONTIC FORCES GENERATED BY A SIMULATED ARCHWIRE APPLIANCE EVALUATED BY THE FINITE-ELEMENT METHOD
    FOTOS, PG
    SPYRAKOS, CC
    BERNARD, DO
    ANGLE ORTHODONTIST, 1990, 60 (04) : 277 - 282
  • [3] Effect of debonding forces on bonded orthodontic brackets: Finite element study
    Lewis, G
    Manickam, S
    Wharton, D
    BIO-MEDICAL MATERIALS AND ENGINEERING, 1996, 6 (02) : 113 - 121
  • [4] THE EFFECT OF ORTHODONTIC VERTICAL FORCES ON THE DENTAL PULP: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS
    Sita, Dragos
    Brezeanu, Ligia
    Bica, Dorin
    Bica, Cristina Ioana
    Monea, Monica
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2018, 10 (02): : 91 - 98
  • [5] Effect of attachment configuration and trim line design on the force system of orthodontic aligners: A finite element study on the upper central incisor
    Elshazly, Tarek M.
    Bourauel, Christoph
    Aldesoki, Mostafa
    Salvatori, Damiano
    Alhotan, Abdulaziz
    Keilig, Ludger
    Ghoneima, Ahmed
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2024, 27 : 131 - 140
  • [6] Effect of trimming line design and edge extension of orthodontic aligners on force transmission: A 3D finite element study
    Elshazly, Tarek M.
    Salvatori, Damiano
    Elattar, Hanaa
    Bourauel, Christoph
    Keilig, Ludger
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 140
  • [7] Finite element study of the effect of material properties on reaction forces produced by solitary wave propagation in granular chains
    Musson, Ryan W.
    Carlson, William
    GRANULAR MATTER, 2016, 18 (02)
  • [8] Finite element study of the effect of material properties on reaction forces produced by solitary wave propagation in granular chains
    Ryan W. Musson
    William Carlson
    Granular Matter, 2016, 18
  • [9] Effect of planar microelectrode geometry on neuron stimulation: Finite element modeling and experimental validation of the efficient electrode shape
    Ghazavi, Atefeh
    Westwick, David
    Xu, Fenglian
    Wijdenes, Pierre
    Syed, Naweed
    Dalton, Colin
    JOURNAL OF NEUROSCIENCE METHODS, 2015, 248 : 51 - 58
  • [10] Analyzing the effect of undermining on suture forces during simulated skin flap surgeries with a three-dimensional finite element method
    Guo, Wenzhangzhi
    Lau, Allison Tsz Kwan
    Davies, Joel C.
    Forte, Vito
    Grinspun, Eitan
    Kahrs, Lueder Alexander
    COMPUTERS & GRAPHICS-UK, 2024, 124