Single pulse data collection with an X-ray chopper at in situ room temperature Laue crystallography beamline BL03HB

被引:0
|
作者
Yu, Li [1 ,2 ]
Wang, Zhijun [3 ]
Pan, Cheng [1 ,2 ]
Zhang, Weizhe [3 ]
Sun, Bo [3 ]
Wang, Sisheng [3 ]
Wang, Qisheng [3 ]
Wen, Wen [3 ]
Gao, Xingyu [3 ]
He, Jianhua [4 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai 201210, Peoples R China
[4] Wuhan Univ, Inst Adv Studies, Wuhan 430072, Peoples R China
关键词
X-ray chopper; Laue crystallography; Exposure time; Pulse data collection; MACROMOLECULAR CRYSTALLOGRAPHY; SYNCHROTRON-RADIATION; INSTRUMENT; SOFTWARE; SYSTEM; CHIP;
D O I
10.1016/j.nima.2024.169891
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
in situ room temperature Laue crystallography has gained increasing attention. This method is suitable for timeresolved Laue crystallography experiments to get crystal structure with only several single-frame data collections. To improve the diffraction efficiency of protein crystals at room temperature, a simple X-ray chopper combined with a fast shutter has been successfully developed and tested at in situ room temperature Laue crystallography beamline BL03HB of the Shanghai Synchrotron Radiation Facility (SSRF). This chopper is built with two aluminum blades. There are two windows on both blades, as well as an internal lead block. The width of windows for transmission of beam can be flexibly adjusted by a steel block coated with lead. The chopping frequency is controlled independently. The device allows chopping frequencies ranging from 0 to 10 Hz, and exposure times down to 100 mu s can be obtained for our Laue diffraction experiment with the combination of a fast shutter. Moreover, a single pulse data collection strategy has been developed at BL03HB. The performance of our single pulse data collection method with the designed chopper for the improvement of data quality has been analyzed. Results show that the quality of diffraction data obtained from the single pulse data collection method is significantly improved, and the developed chopper is very suitable for room temperature Laue crystallography experiments at the synchrotron beamline with super bending magnet as light source.
引用
收藏
页数:10
相关论文
共 14 条
  • [1] BL03HB: a Laue microdiffraction beamline for both protein crystallography and materials science at SSRF
    Wang, Zhi-Jun
    Wang, Si-Sheng
    Su, Zheng-Huang
    Yu, Li
    Wang, Yu-Zhu
    Sun, Bo
    Wen, Wen
    Gao, Xing-Yu
    NUCLEAR SCIENCE AND TECHNIQUES, 2024, 35 (07)
  • [2] BL03HB: a Laue microdiffraction beamline for both protein crystallography and materials science at SSRF
    ZhiJun Wang
    SiSheng Wang
    ZhengHuang Su
    Li Yu
    YuZhu Wang
    Bo Sun
    Wen Wen
    XingYu Gao
    Nuclear Science and Techniques, 2024, 35 (07) : 105 - 115
  • [3] THE COLLECTION OF X-RAY DIFFRACTION DATA FROM SINGLE CRYSTALS AT LIQUID HYDROGEN TEMPERATURE
    FORRESTER, JD
    ACTA CRYSTALLOGRAPHICA, 1960, 13 (12): : 1103 - 1103
  • [4] High-throughput in situ X-ray screening of and data collection from protein crystals at room temperature and under cryogenic conditions
    Jana Broecker
    Takefumi Morizumi
    Wei-Lin Ou
    Viviane Klingel
    Anling Kuo
    David J Kissick
    Andrii Ishchenko
    Ming-Yue Lee
    Shenglan Xu
    Oleg Makarov
    Vadim Cherezov
    Craig M Ogata
    Oliver P Ernst
    Nature Protocols, 2018, 13 : 260 - 292
  • [5] High-throughput in situ X-ray screening of and data collection from protein crystals at room temperature and under cryogenic conditions
    Broecker, Jana
    Morizumi, Takefumi
    Ou, Wei-Lin
    Klingel, Viviane
    Kuo, Anling
    Kissick, David J.
    Ishchenko, Andrii
    Lee, Ming-Yue
    Xu, Shenglan
    Makarov, Oleg
    Cherezov, Vadim
    Ogata, Craig M.
    Ernst, Oliver P.
    NATURE PROTOCOLS, 2018, 13 (02) : 260 - 291
  • [6] From then till now: changing data collection methods in single crystal X-ray crystallography since 1912
    Powell, Harold R.
    CRYSTALLOGRAPHY REVIEWS, 2019, 25 (04) : 264 - 294
  • [7] Using cryoloops for X-ray data collection from protein crystals at room temperature: A simple applicable method
    Li, SJ
    Suzuki, M
    Nakagawa, A
    JOURNAL OF CRYSTAL GROWTH, 2005, 281 (2-4) : 592 - 595
  • [8] Polymer-based microfluidic device for on-chip counter-diffusive crystallization and in situ X-ray crystallography at room temperature
    Saha, Sarthak
    oezden, Can
    Samkutty, Alfred
    Russi, Silvia
    Cohen, Aina
    Stratton, Margaret M.
    Perry, Sarah L.
    LAB ON A CHIP, 2023, 23 (08) : 2075 - 2090
  • [9] High-energy x-ray diffraction studies of alkylimidazolium fluorohydrogenate room temperature molten salts at spring-8 high-energy x-ray diffraction beamline BL04B2
    Kohara, S
    Hagiwara, R
    Matsumoto, K
    Ito, Y
    Kajinami, A
    Suzuya, K
    MOLTEN SALTS XIII, 2002, 2002 (19): : 1047 - 1056
  • [10] Neutron and high-resolution room-temperature X-ray data collection from crystallized lytic polysaccharide monooxygenase
    Bacik, John-Paul
    Mekasha, Sophanit
    Forsberg, Zarah
    Kovalevsky, Andrey
    Nix, Jay C.
    Cuneo, Matthew J.
    Coates, Leighton
    Vaaje-Kolstad, Gustav
    Chen, Julian C. -H.
    Eijsink, Vincent G. H.
    Unkefer, Clifford J.