Highly Sensitive and Flexible Copper Oxide/Graphene Non-Enzymatic Glucose Sensor by Laser Direct Writing

被引:1
|
作者
Li, Qi [1 ]
Yang, Dasheng [1 ]
Gao, Yang [1 ,2 ]
Wang, Ziyang [1 ]
Yin, Ruixue [1 ]
Xuan, Fuzhen [1 ,3 ]
机构
[1] East China Univ Sci & Technol, Sch Mech & Power Engn, Shanghai 200237, Peoples R China
[2] Huazhong Univ Sci & Technol, Wuhan Natl Lab Optoelect, Wuhan 430074, Hubei, Peoples R China
[3] East China Univ Sci & Technol, Shanghai Collabrat Ctr High end Equipment Reliabil, Shanghai 200237, Peoples R China
来源
ADVANCED SENSOR RESEARCH | 2023年 / 2卷 / 06期
关键词
copper oxide; flexible sensors; glucose detection; graphene; laser direct writing; CU NANOPARTICLES; EFFICIENT; NI; PERFORMANCE; FABRICATION; DEPOSITION; FILMS; OXIDE;
D O I
10.1002/adsr.202200067
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accurate and convenient detection of human blood glucose levels is an effective method for early diagnosis of diabetes and prevention of complications. The flexible and wearable electrochemical glucose sensor with low cost, fast responsiveness, good stability, reliability, and high sensitivity has attracted much attention in monitoring glucose concentration. The preparation of a conductive layer with catalytic activity on a flexible substrate is the key to making a wearable glucose sensor. Here, graphene composite materials sintered with copper oxide (CuO) nanoparticles are successfully prepared on a polyimide film by laser direct writing method and fabricated a flexible non-enzymatic glucose sensor using laser-engraved graphene (LEG) as a conductive electrode. The CuO/LEG sensor exhibits a high sensitivity of 619.43 mu A mm-1 cm-2 in 0-3 mm glucose and 462.96 mu A mm-1 cm-2 in 0-8 mm glucose. In addition, the CuO/LEG sensor shows good reproducibility, high anti-interference capability, and long-term stability. It also presents good bending stability, which can maintain 82.40% initial current after 100 times bending. Moreover, the CuO/LEG sensor has an obvious step-ampere response in the detection of sweat samples, indicating the great potential of wearable sweat sensors. A high-performance copper oxide (CuO)/laser-engraved graphene (LEG) based non-enzymatic glucose sensor is prepared by laser direct writing method. The CuO/LEG sensor exhibits a high sensitivity of 619.43 mu A mm-1 cm-2 in 0-3 mm glucose and 462.96 mu A mm-1 cm-2 in 0-8 mm glucose. Moreover, the CuO/LEG sensor also shows good selectivity, reproducibility, long-term stability, and bending stability. image
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Highly sensitive non-enzymatic glucose sensor based on copper oxide nanorods
    Haneen Ali Jasim
    Osama Abdul Azeez Dakhil
    Journal of Nanoparticle Research, 2022, 24
  • [2] Highly sensitive non-enzymatic glucose sensor based on copper oxide nanorods
    Jasim, Haneen Ali
    Dakhil, Osama Abdul Azeez
    JOURNAL OF NANOPARTICLE RESEARCH, 2022, 24 (11)
  • [3] Highly sensitive non-enzymatic glucose sensor with copper oxide nanoparticle impregnated mesoporous silica
    Anees Y. Khan
    Rajdip Bandyopadhyaya
    Journal of Porous Materials, 2021, 28 : 1097 - 1104
  • [4] Highly sensitive non-enzymatic glucose sensor with copper oxide nanoparticle impregnated mesoporous silica
    Khan, Anees Y.
    Bandyopadhyaya, Rajdip
    JOURNAL OF POROUS MATERIALS, 2021, 28 (04) : 1097 - 1104
  • [5] A flexible non-enzymatic glucose sensor based on copper nanoparticles anchored on laser-induced graphene
    Zhang, Yue
    Li, Na
    Xiang, Yangjun
    Wang, Debo
    Zhang, Peng
    Wang, Yanyan
    Lu, Shan
    Xu, Rongqing
    Zhao, Jiang
    CARBON, 2020, 156 : 506 - 513
  • [6] Highly sensitive non-enzymatic glucose sensor based on Pt nanoparticle decorated graphene oxide hydrogel
    Hoa, Le Thuy
    Sun, Kang Gyu
    Hur, Seung Hyun
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 : 618 - 623
  • [7] Use of carbon supports with copper ion as a highly sensitive non-enzymatic glucose sensor
    Zheng, Weiran
    Li, Yong
    Hu, Liangsheng
    Lee, Lawrence Yoon Suk
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 282 : 187 - 196
  • [8] Multi-dimensional Ag/NiO/reduced graphene oxide nanostructures for a highly sensitive non-enzymatic glucose sensor
    Yen-Linh Thi Ngo
    Le Thuy Hoa
    Chung, Jin Suk
    Hur, Seung Huyn
    JOURNAL OF ALLOYS AND COMPOUNDS, 2017, 712 : 742 - 751
  • [9] Non-enzymatic Amperometric Glucose Sensor Based on Copper Nanowires Decorated Reduced Graphene Oxide
    Ju, Lele
    Wu, Guosong
    Lu, Biao
    Li, Xiaoyun
    Wu, Huaping
    Liu, Aiping
    ELECTROANALYSIS, 2016, 28 (10) : 2543 - 2551
  • [10] Non-enzymatic Glucose Sensor Based on Graphene Oxide/ZnO Nanoarrays
    Liang X.
    Han L.
    Lei Y.
    Li W.
    Huang R.
    Chen R.
    Ni H.
    Zhan W.
    Cailiao Daobao/Materials Reports, 2022, 36 (13):