Neutron Spectroscopy in Perpendicular Neutral Beam Injection Deuterium Plasmas Using Newly Developed Compact Neutron Emission Spectrometers

被引:0
|
作者
Sangaroon, Siriyaporn [1 ]
Ogawa, Kunihiro [2 ]
Isobe, Mitsutaka [2 ]
Liao, Longyong [3 ]
Zhong, Guoqiang [4 ]
Wisitsorasak, Apiwat [5 ]
Takada, Eiji [6 ]
Kobayashi, Makoto Inami [2 ]
Poolyarat, Nopporn [7 ]
Murakami, Sadayoshi [8 ]
Seki, Ryohsuke [2 ]
Nuga, Hideo [2 ]
Osakabe, Masaki [2 ]
机构
[1] Mahasarakham Univ, Fac Sci, Dept Phys, Maha Sarakham 44150, Thailand
[2] Natl Inst Fus Sci, Toki 5095202, Japan
[3] Grad Univ Adv Studies, Dept Res, SOKENDAI, Hayama 5095202, Japan
[4] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
[5] King Mongkuts Univ Technol Thonburi, Fac Sci, Dept Phys, Bangkok 10140, Thailand
[6] Natl Inst Technol, Tokyo 1010003, Japan
[7] Thailand Inst Nucl Technol, Bangkok 10900, Thailand
[8] Kyoto Univ, Dept Nucl Engn, Kyoto 6158540, Japan
关键词
Ions; Neutrons; Plasmas; Heating systems; Particle beams; Particle beam injection; Detectors; Compact neutron emission spectrometer (CNES); Cs2LiYCl6:Ce scintillation detector enriched with Li-7 (CLYC7); EJ-301; ion cyclotron range of frequency (ICRF) wave; large helical device (LHD); neutral beam (NB) injection; ENERGY-SPECTRA; JET; SCINTILLATOR; DETECTORS; CS2LIYCL6;
D O I
10.1109/TIM.2024.3446631
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The presence of helically trapped fast ions in helical ripples in the large helical device (LHD), resulting from a perpendicularly injected positive-ion-source-based neutral beam (P-NB)-heated plasma and/or from ion cyclotron range of frequency (ICRF) wave-heated plasma, poses a significant concern due to the system's lack of symmetry. In response to this challenge, compact neutron emission spectrometers (CNESs) have been strategically developed in the LHD, featuring a perpendicular line of sight relative to the plasma's magnetic field. The first perpendicular CNES offered a vertical field of view through the deuterium plasma and incorporated a liquid (EJ-301) scintillation detector optimized for efficient operation at a high neutron emission rate. The second perpendicular CNES was operated using a Cs2LiYCl6:Ce scintillation detector enriched with 7Li (CLYC7), providing a horizontal field of view through the deuterium plasma and effectively operating in a region characterized by relatively low neutron emission rates. During plasma heating through P-NB, both perpendicular CNESs showed a neutron energy distribution, featuring a double-humped profile with two peaks at energy of approximately 2.30 and 2.74 MeV. Furthermore, the deuterium-deuterium neutron energy spectrum expected to be obtained by perpendicular CNES was calculated using the 5-D orbit following code DELTA5D and considering the Larmor motion effect. The results revealed that the experimentally obtained neutron energies were almost consistent with the neutron energies calculated based on the orbit following model. These peaks aligned with the Larmor motion of deuterons resulting from P-NB injection at the helical ripple of the LHD. In addition, we conducted neutron spectroscopy involving deuterium-deuterium interactions in a deuterium plasma simultaneously heated by both P-NB and ICRF wave, characterized by a high neutron emission rate, using perpendicular CNES based on EJ-301. The observation revealed a broadening in spectrum width, attributed to the additional ICRF wave heating.
引用
收藏
页数:11
相关论文
共 29 条
  • [1] MEASUREMENT OF THE FRACTIONAL THERMONUCLEAR NEUTRON YIELD DURING DEUTERIUM NEUTRAL-BEAM INJECTION INTO DEUTERIUM PLASMAS
    LOUGHLIN, MJ
    VANBELLE, P
    HAWKES, NP
    JARVIS, ON
    SADLER, G
    SYME, DB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 281 (01): : 184 - 191
  • [2] Projected neutron emission spectroscopy diagnosis of jet deuterium plasmas
    Gorini, G
    Conroy, S
    Ericsson, G
    Giacomelli, L
    Henriksson, H
    Hjalmarsson, A
    Källne, J
    Tardocchi, M
    ADVANCED DIAGNOSTICS FOR MAGNETIC AND INERTIAL FUSION, 2002, : 117 - 120
  • [3] Neutron emission in neutral beam heated KSTAR plasmas and its application to neutron radiography
    Kwak, Jong-Gu
    Kim, H. S.
    Cheon, M. S.
    Oh, S. T.
    Lee, Y. S.
    Terzolo, L.
    FUSION ENGINEERING AND DESIGN, 2016, 109 : 608 - 612
  • [4] Neutron emission spectroscopy of D plasmas at JET with a compact liquid scintillating neutron spectrometer
    Giacomelli, L.
    Belli, F.
    Binda, F.
    Conroy, S. W.
    Eriksson, J.
    Milocco, A.
    Popovicev, S.
    Syme, D. B.
    Abduallev, S.
    Abhangi, M.
    Abreu, P.
    Afzal, M.
    Aggarwal, K. M.
    Ahlgren, T.
    Ahn, J. H.
    Aho-Mantila, L.
    Aiba, N.
    Airila, M.
    Albanese, R.
    Aldred, V.
    Alegre, D.
    Alessi, E.
    Aleynikov, P.
    Alfier, A.
    Alkseev, A.
    Allinson, M.
    Alper, B.
    Alves, E.
    Ambrosino, G.
    Ambrosino, R.
    Amicucci, L.
    Amosov, V.
    Sunden, E. Andersson
    Angelone, M.
    Anghel, M.
    Angioni, C.
    Appel, L.
    Appelbee, C.
    Arena, P.
    Ariola, M.
    Arnichand, H.
    Arshad, S.
    Ash, A.
    Ashikawa, N.
    Aslanyan, V.
    Asunta, O.
    Auriemma, F.
    Austin, Y.
    Avotina, L.
    Axton, M. D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [5] Observation of neutron emission anisotropy by neutron activation measurement in beam-injected LHD deuterium plasmas
    Sugiyama, S.
    Nishitani, T.
    Matsuura, H.
    Isobe, M.
    Ogawa, K.
    Tanaka, T.
    Yoshihashi, S.
    Uritani, A.
    Osakabe, M.
    NUCLEAR FUSION, 2020, 60 (07)
  • [6] Simulation of neutron emission in neutral beam injection heated plasmas with the real-time code RABBIT
    Weiland, M.
    Bilato, R.
    Collins, C. S.
    Heidbrink, W. W.
    Liu, D.
    Van Zeeland, M. A.
    Abduallev, S.
    Abhangi, M.
    Abreu, P.
    Afzal, M.
    Aggarwal, K. M.
    Ahlgren, T.
    Ahn, J. H.
    Aho-Mantila, L.
    Aiba, N.
    Airila, M.
    Albanese, R.
    Aldred, V.
    Alegre, D.
    Alessi, E.
    Aleynikov, P.
    Alfier, A.
    Alkseev, A.
    Allinson, M.
    Alper, B.
    Alves, E.
    Ambrosino, G.
    Ambrosino, R.
    Amicucci, L.
    Amosov, V.
    Sunden, E. Andersson
    Angelone, M.
    Anghel, M.
    Angioni, C.
    Appel, L.
    Appelbee, C.
    Arena, P.
    Ariola, M.
    Arnichand, H.
    Arshad, S.
    Ash, A.
    Ashikawa, N.
    Aslanyan, V.
    Asunta, O.
    Auriemma, F.
    Austin, Y.
    Avotina, L.
    Axton, M. D.
    Ayres, C.
    Bacharis, M.
    NUCLEAR FUSION, 2019, 59 (08)
  • [7] Prediction of Neutron Emission Rate in Deuterium Neutral Beam Heated CFQS Plasmas Using FIT3D-DD Code
    Seki, Ryosuke
    Ogawa, Kunihiro
    Isobe, Mitsutaka
    Murakami, Sadayoshi
    Nuga, Hideo
    Shimizu, Akihiro
    Okamura, Shoichi
    Takahashi, Hiromi
    Oishi, Tetsutaro
    Kinoshita, Shigeyoshi
    Murase, Takanori
    Nakagawa, Sho
    Tanoue, Hiroyuki
    Osakabe, Masaki
    Liu, Haifeng
    Xu, Yuhong
    PLASMA AND FUSION RESEARCH, 2022, 17
  • [8] NEUTRON TIME BEHAVIOR DUE TO DEUTERIUM NEUTRAL BEAM INJECTION INTO A HYDROGEN PLASMA
    ENGLAND, AC
    FOWLER, RH
    HOWE, HC
    MIHALCZO, JT
    ROME, JA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (09): : 1072 - 1072
  • [9] Time dependent neutron emission rate analysis for neutral-beam-heated deuterium plasmas in a helical system and tokamaks
    Ogawa, Kunihiro
    Isobe, Mitsutaka
    Nishitani, Takeo
    Seki, Ryosuke
    Nuga, Hideo
    Murakami, Sadayoshi
    Nakata, Motoki
    Pu, Neng
    Osakabe, Masaki
    Jo, Jungmin
    Cheon, MunSeong
    Kim, Junghee
    Zhong, Guoqiang
    Xiao, Min
    Hu, Liqun
    PLASMA PHYSICS AND CONTROLLED FUSION, 2018, 60 (09)
  • [10] Velocity-space sensitivities of neutron emission spectrometers at the tokamaks JET and ASDEX Upgrade in deuterium plasmas
    Jacobsen, A. S.
    Binda, F.
    Cazzaniga, C.
    Eriksson, J.
    Hjalmarsson, A.
    Nocente, M.
    Salewski, M.
    Tardini, G.
    Abduallev, S.
    Abhangi, M.
    Abreu, P.
    Afzal, M.
    Aggarwal, K. M.
    Ahlgren, T.
    Ahn, J. H.
    Aho-Mantila, L.
    Aiba, N.
    Airila, M.
    Albanese, R.
    Aldred, V.
    Alegre, D.
    Alessi, E.
    Aleynikov, P.
    Alfier, A.
    Alkseev, A.
    Allinson, M.
    Alper, B.
    Alves, E.
    Ambrosino, G.
    Ambrosino, R.
    Amicucci, L.
    Amosov, V.
    Sunden, E. Andersson
    Angelone, M.
    Anghel, M.
    Angioni, C.
    Appel, L.
    Appelbee, C.
    Arena, P.
    Ariola, M.
    Arnichand, H.
    Arshad, S.
    Ash, A.
    Ashikawa, N.
    Aslanyan, V.
    Asunta, O.
    Auriemma, F.
    Austin, Y.
    Avotina, L.
    Axton, M. D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (07):