摘要
Increasing population density and urbanization have intensified the need for high-rise buildings in recent years. The seismic resistance of high-rise buildings should be carefully concerned in seismic regions, especially for super high-rise buildings which are most vulnerable to long-period earthquakes. This paper introduced the model design of a 499 m super high-rise mega framedouble core tube composite structure and presented the shaking table test results of the 1/50 scaled structural model. This super high-rise building possesses many conducive merits to resist seismic hazard, including steel reinforced concrete members, high-strength concrete and double core tube. In the test, there were three groups of long-period earthquakes and four incremental seismic intensity levels considered. The test phenomena indicated that the coupling beams of exterior tube were the first line of defense to resist seismic actions. The existence of inner tube improved the shear resistance of this building and there was no observed shear damage on the walls. Based on the instrumented data, the vibration characteristics, acceleration, displacement and strain responses of the structure were reported. The seismic performance of this super highrise building meets the requirements of design specifications and its collapse resistance capacity is physically proved under severe earthquakes. However, the whiplash effect of acceleration is serious on the roof due to the reduction of mass and constraint for the mega column end. Furthermore, the inter-story drifts and strain responses of trusses in the top region are significantly larger. For the seismic measurement, great attentions should be paid to the exterior coupling beams and structural members in the top region of this super high-rise building. The presented work provides well experimental confirmation and reference for super high-rise buildings with mega frame-double core tube composite system.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Influence of outrigger truss system on the seismic fragility of super high-rise braced mega frame-core tube structure
    Shan, Wenchen
    Lin, Xuchuan
    Zhou, Xuhong
    Dong, Biqin
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [2] Experimental study on seismic performance of super high-rise building with topology optimized diagonal mega frame
    Zhao, Bin
    Yi, Jie
    Jiang, Chun
    Lu, Xilin
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [3] Seismic Behavior of Super High-rise Frame-core Wall Structure
    Yuan Jixing
    Zhang Qing
    VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT II, PTS 1-3, 2012, 226-228 : 967 - 971
  • [4] Study on seismic behavior and collapse risk of super high-rise braced mega frame-core tube structural system
    Shan, Wenchen
    Zhou, Xuhong
    Lin, Xuchuan
    Bao, Lianjin
    Chen, Y. Frank
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2024, 177
  • [5] Seismic Vulnerability Analysis of High-Rise Composite Frame Concrete Tube Composite Structure
    Zhang, Shuyun
    Zhou, Jie
    Hao, Yonglei
    6TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND CIVIL ENGINEERING, 2020, 455
  • [6] Seismic analysis of high-rise mega-braced frame-core buildings
    Brunesi, E.
    Nascimbene, R.
    Casagrande, L.
    ENGINEERING STRUCTURES, 2016, 115 : 1 - 17
  • [7] Seismic performance of high-rise steel frame structure with braces
    Jia, Ming-Ming
    Zhang, Su-Mei
    Jiang, Shou-Lan
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2007, 39 (SUPPL. 2): : 333 - 337
  • [8] Mechanical and deflection performance of frame-tube structure with outriggers in super high-rise buildings
    Zhang, Wei
    Zeng, Deguang
    Liu, Jun
    Liang, Xingwen
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2009, 30 (SUPPL. 1): : 169 - 175
  • [9] Seismic performance of braced mega frame-core tube structure system
    Zhou X.
    Shan W.
    Liu J.
    Lin X.
    Fu X.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 (01): : 75 - 83
  • [10] Seismic Performance Research of High-Rise Diagrid Tube-Core Tube Structures
    Teng, Jun
    Guo, Weiliang
    Rong, Baisheng
    Li, Zuohua
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 2005 - 2012