摘要
Understanding the intrinsic thermal transport behavior of living blood-perfused tissue is essential in applications that require predicting the correct thermoregulation behavior of humans, discovering the location of abnormal tissues, and treating cancer through hyperthermia or thermal ablation. In this study, we employ an in vivo measurement technique that genuinely measures the intrinsic tissue thermal conductivity and blood perfusion rate as a function of tissue temperature. The emphasis is on "in vivo" measurement because physiological differences across individuals must be considered (e.g., water content within the tissue). Tissue temperatures from 30.5 degrees C to 35.5 degrees C yielded average intrinsic thermal conductivity values of 0.33 +/- 0.04 W/m-K in three subjects. This value agrees well with that of excised human epidermis (0.21-0.41 W/m-K). The blood perfusion rate inevitably increased from 1.43 x 10-4 to 3.42 x 10-3 m3/s/m3 with increasing tissue temperature consequently from vasomotion. The findings suggest that the proposed approach can serve as a noninvasive, real-time, personalized, and in vivo method for determining the intrinsic thermal behavior of living blood-perfused tissue. Such a methodology also has the potential to revolutionize fields that deal with tumor modeling, treatment, and thermal comfort optimization, ultimately benefiting human health and well-being.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Determination of myoglobin concentration in blood-perfused tissue
    Masuda, Kazumi
    Truscott, Kent
    Lin, Ping-Chang
    Kreutzer, Ulrike
    Chung, Youngran
    Sriram, Renuka
    Jue, Thomas
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2008, 104 (01) : 41 - 48
  • [2] Determination of myoglobin concentration in blood-perfused tissue
    Kazumi Masuda
    Kent Truscott
    Ping-Chang Lin
    Ulrike Kreutzer
    Youngran Chung
    Renuka Sriram
    Thomas Jue
    European Journal of Applied Physiology, 2008, 104 : 41 - 48
  • [3] Norepinephrine measurement in the isolated, blood-perfused papillary muscle of the dog by using ex vivo microdialysis
    Seya, K
    Daitoku, K
    Motomura, S
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1999, 42 (03) : 149 - 155
  • [4] Evaluation of an ex vivo model of the blood-perfused equine uterus
    Koehne, Martin
    Unruh, Christin
    Boettcher, Denny
    Toenissen, Anna
    Ulrich, Reiner
    Sieme, Harald
    THERIOGENOLOGY, 2022, 184 : 82 - 91
  • [5] Optical signal interrogation depth in Tyrode and blood-perfused myocardial tissue
    Kanaporis, Giedrius
    Jurevicius, Jonas
    Navalinskas, Antanas
    Vosyliute, Ruta
    Matiukas, Arvydas
    Mitrea, Bogdan G.
    Pertsov, Arkady M.
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2011, 40 : 131 - 131
  • [6] Photon Diffusion Attenuation Length in Tyrode and Blood-Perfused Myocardial Tissue
    Kanaporis, Giedrius
    Navalinskas, Antanas
    Matiukas, Arvydas
    Mitrea, Bogdan G.
    Vosyliute, Ruta
    Jurevicius, Jonas
    Pertsov, Arkady M.
    BIOPHYSICAL JOURNAL, 2011, 100 (03) : 318 - 318
  • [7] MEASUREMENT OF FILTRATION COEFFICIENT IN BLOOD-PERFUSED HOLLOW FIBERS USING AN OPTICAL TECHNIQUE
    HARRIS, NR
    ROSELLI, RJ
    PARKER, RE
    FASEB JOURNAL, 1991, 5 (04): : A754 - A754
  • [8] COLORIMETRIC DEVICE FOR MEASUREMENT OF TRANS-VASCULAR FLUID FLUX IN BLOOD-PERFUSED ORGANS
    OPPENHEIMER, L
    RICHARDSON, WN
    BILAN, D
    HOPPENSACK, M
    JOURNAL OF APPLIED PHYSIOLOGY, 1987, 62 (01) : 364 - 372
  • [9] Effect of effective tissue conductivity on thermal dose distributions of living tissue with directional blood flow during thermal therapy
    Shih, TC
    Kou, HS
    Lin, WL
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2002, 29 (01) : 115 - 126
  • [10] EVALUATION OF LOCAL TISSUE BLOOD FLOW BY CONTINUOUS DIRECT MEASUREMENT OF THERMAL CONDUCTIVITY
    LEVY, L
    GRAICHEN, H
    STOLWIJK, JA
    CALABRES.M
    JOURNAL OF APPLIED PHYSIOLOGY, 1967, 22 (05) : 1026 - &