Numerical study on the seismic performance of H-beam to built-in CFRP circular tube CFST column joint with replaceable energy dissipation angle steel

被引:0
|
作者
Li, Guochang [1 ]
Qin, Zhuangwen [1 ]
Li, Xiao [1 ]
Liu, Mo [1 ]
机构
[1] Shenyang Jianzhu Univ, Sch Civil Engn, Shenyang 110168, Peoples R China
基金
中国国家自然科学基金;
关键词
Earthquake resilience; CFRP circular tube; Concrete-filled square steel; Outer diaphragm; Assembled joint; BEHAVIOR; CONNECTIONS;
D O I
10.1016/j.istruc.2024.106793
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Based on the idea of failure mode control and earthquake resilience, a H-beam to built-in CFRP circular tube CFST column joint with replaceable energy dissipation angle steel was proposed in this paper. The finite element models of the joint were established by ABAQUS software to reveal its working mechanism and seismic performance under low cycle reciprocating load. Based on the analysis of the working mechanism, the effects of angle steel thickness, assembled energy-dissipation beam free deformable length, outer diaphragm thickness, and the number of CFRP layers on the seismic performance of the joint were analyzed. The simulation results indicate that the hysteretic curves of the joint are plump with an equivalent viscous damping coefficient of 0.283-0.362, and the ductility factor of the joint is 3.43-7.17, which proves good seismic performance and deformability. The plastic hinges are also effectively transferred to the assembled energy-dissipation beam. When the joint is damaged, the main structural members are basically in the elastic state except for assembled energy-dissipation beams. This means that the proposed joint can accomplish recoverable seismic performance and controllable failure mode. Furthermore, based on the optimal seismic performance of the joint, it is recommended that the angle steel thickness be taken as 0.8-0.9 times the H-beam flange thickness, the outer diaphragm thickness be taken as 1.5 times the angle steel thickness, the assembled energy-dissipation beam free deformable length be taken as 0.8-1.3 times of the H-beam flange width. The CFRP configuration rate can be designed by the strength and stiffness requirements of the frame column in the structural system.
引用
收藏
页数:15
相关论文
共 32 条
  • [1] Seismic Performance of Steel Beam-To-Column Joint with Replaceable Buckling-Restrained Energy Dissipation Fuses
    Chen, Peng
    Hu, Fangxin
    Pan, Jianrong
    Wang, Zhan
    PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, STESSA 2022, 2022, 262 : 820 - 827
  • [2] Seismic performance of joint for H-beam to CFST column with field-bolted flange-splicing
    Zhang, Ai-Lin
    Li, Chuan-Hao
    Liu, Xue-Chun
    Chen, Xuesen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 196
  • [3] Seismic performance analysis of steel beam to CFST column connection with ductility and energy dissipation components
    Wang, Jingxuan
    Li, Qiuying
    Wei, Guoqiang
    JOURNAL OF VIBROENGINEERING, 2020, 22 (01) : 131 - 144
  • [4] Seismic performance and design of an innovative dual vertical diaphragms joint between flat CFST column and H-beam
    Deng, En-Feng
    Wu, Shao-Tong
    Qian, Hui
    He, Jin -Ming
    Zhang, Jun-Feng
    Yu, Hong -Xia
    JOURNAL OF BUILDING ENGINEERING, 2024, 87
  • [5] Study of seismic performance and resilience of a precast concrete beam-column joint with a replaceable energy-dissipation component
    Ge, Qi
    Ai, Jingsong
    Mao, Yu
    Zhou, Decai
    Li, Youjie
    Lu, Yang
    Xiong, Feng
    JOURNAL OF BUILDING ENGINEERING, 2025, 103
  • [6] SEISMIC PERFORMANCE ANALYSIS OF NOVEL PRECAST CONCRETE BEAM-COLUMN JOINT WITH REPLACEABLE ENERGY DISSIPATION DEVICES
    Ge Q.
    Li Y.-J.
    Xiong F.
    He Y.
    Shen H.
    Li Y.
    He Y.-X.
    Gongcheng Lixue/Engineering Mechanics, 2024, 41 : 57 - 65
  • [7] Seismic performance of prefabricated beam-to-column joint with replaceable energy-dissipating steel hinge
    Zheng, Lian-Qiong
    Chen, Xiao-Yang
    Wei, Chang-Gui
    Yan, Gui-Yun
    BULLETIN OF EARTHQUAKE ENGINEERING, 2022, 20 (03) : 1865 - 1895
  • [8] Seismic performance of prefabricated beam-to-column joint with replaceable energy-dissipating steel hinge
    Lian-Qiong Zheng
    Xiao-Yang Chen
    Chang-Gui Wei
    Gui-Yun Yan
    Bulletin of Earthquake Engineering, 2022, 20 : 1865 - 1895
  • [9] Experimental on seismic performance of replaceable splicing steel beam-column joints with friction energy dissipation components
    Diao, Yan-Song
    Ren, Yi-Jian
    Yang, Yuan-Qiang
    Zhao, Ling-Yun
    Liu, Xiu-Li
    Liu, Yun
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2024, 54 (06): : 1643 - 1656
  • [10] Experimental study on seismic performance of replaceable beam-column connector with single-sided angle steel
    Sun D.-D.
    Yang Y.
    Ma Y.-K.
    Zhou H.-Y.
    Xue Y.-C.
    Yu Y.-L.
    Gongcheng Lixue/Engineering Mechanics, 2022, 39 (04): : 151 - 163