Experimental investigation of nanosecond pulsed laser ablation of polycrystalline diamond composite

被引:0
|
作者
Zahrani, Esmaeil Ghadiri [1 ,2 ]
Azarhoushang, Bahman [1 ]
机构
[1] Hsch Furtwangen Univ, Inst Adv Mfg KSF, D-78532 Tuttlingen, Germany
[2] Univ Freiburg, Dept Microsyst Engn IMTEK, D-79110 Freiburg, Germany
来源
关键词
Nanosecond laser ablation; Single point; Polycrystalline diamond composite; PCD; Pulse energy; Laser input density; Scan repeats; Ablation pile-up; PCD; FABRICATION; PICOSECOND;
D O I
10.1016/j.optlastec.2024.111634
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A fundamental understanding of the laser ablation of polycrystalline diamond composite (PCD) at different laser energy intensities is indispensable for extending these findings to practical applications where, through appropriate parameter combinations, a substantial amount of material with minimal thermal damage should be removed. The objective of this study is to investigate experimentally the nanosecond ablation of polycrystalline diamond composite at different laser pulse energies and input energy densities. The research comprised two distinct categories of experiments: (1) single-point and (2) line experiments. In single-point tests, the number of the incidence pulses (N.P) was varied from 1 to 100 pulses with different pulse energies (Ep) ranging from 40 to 200 mu J. As the N.Ps increased, the ablation depth increased as well. No considerable enhancement in ablation depth was observed with the increase in pulse energies. For the line experiments, the results emphasized the differences in ablation depths by nearly a factor of 2, resulting in a corresponding change in laser input densities from 6.5 J/mm2 to 1.3 J/mm2. The ablation difference was pronounced as the number of repeats of the scanning path increased. The results emphasize that the ablation depth varies at the same pulse energy when the pulse overlap decreased from 100 % to lower percentages. Based on these results, a constant laser energy density with three different combinations of laser inputs-namely, scanning speed and average power-was selected to evaluate the ablation depth and quality. The results show that in moderate numbers of scan repeats (here 20, 30 & 40 times), it is advisable to adopt a minimum pulse energy when the same ablation depth is achieved compared to higher pulse energies. The ablation pile-up was also evaluated in these repeat ranges, indicating that higher pulse energies and repeats do not result in ablation improvement and cause excessive melt deposition.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Temperature evolution and material removal mechanisms in nanosecond-pulsed laser ablation of polycrystalline diamond
    Wu, Qi
    Wang, Jun
    Huang, Chuanzhen
    Li, Huaizhong
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2015, 229 (08) : 1357 - 1372
  • [2] Experimental and theoretical investigation of ultrashort pulsed laser ablation of diamond
    Boerner, Paul
    Hajri, Melik
    Ackerl, Norbert
    Wegener, Konrad
    [J]. JOURNAL OF LASER APPLICATIONS, 2019, 31 (02)
  • [3] Numerical and experimental investigation on pulsed nanosecond laser ablation processing of aluminum alloy
    Peng, Zhang
    Yin, Jiaheng
    Cui, Yaowen
    Cao, Yongzhi
    Lu, Lihua
    Yan, Yongda
    Hu, Zhengjiang
    [J]. JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2022, 19 : 4708 - 4720
  • [4] Investigation of metal-coating-assisted IR nanosecond pulsed laser ablation of CVD diamond
    Chen, Ni
    Wang, Runkai
    Nagarajan, Balasubramanian
    Yan, Bo
    Wu, Yang
    He, Ning
    Castagne, Sylvie
    [J]. JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2022, 18 : 4114 - 4129
  • [5] Investigation on the material removal behavior of single crystal diamond by infrared nanosecond pulsed laser ablation
    Zhang, Zhen
    Zhang, Quanli
    Wang, Qiwen
    Su, Honghua
    Fu, Yucan
    Xu, Jiuhua
    [J]. OPTICS AND LASER TECHNOLOGY, 2020, 126
  • [6] Atomistic Simulations of Ultrashort Pulsed Laser Ablation of Polycrystalline Diamond
    Li, Z. Q.
    Wang, J.
    Sun, T.
    [J]. CURRENT NANOSCIENCE, 2013, 9 (06) : 804 - 811
  • [7] The ablation behavior of diamond/Cu composites by infrared nanosecond pulsed laser
    Ju, Shiling
    Zhang, Quanli
    Wu, Mingtao
    Nie, Riming
    Zhu, Yandan
    [J]. Diamond and Related Materials, 2024, 149
  • [8] Experimental investigation of the nanosecond laser ablation rate of aluminum
    Stafe, M.
    Vladoiu, I.
    Negutu, C.
    Popescu, I. M.
    [J]. ROMANIAN REPORTS IN PHYSICS, 2008, 60 (03) : 789 - 796
  • [9] Experimental Investigation of Nanosecond Laser Ablation of Carbon Nanotubes
    Pachon, Oscar
    Ma, J.
    Schaper, Nicholas
    Jahan, M. P.
    Lei, Shuting
    Kuljanishvili, Irma
    [J]. PROCEEDINGS OF ASME 2021 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE2021), VOL 2B, 2021,
  • [10] Modeling of the temperature field in nanosecond pulsed laser ablation of single crystalline diamond
    Zhang, Zhen
    Zhang, Quanli
    Wang, Yeqing
    Xu, Jiuhua
    [J]. DIAMOND AND RELATED MATERIALS, 2021, 116