High-quality FLORET UTE imaging for clinical translation

被引:0
|
作者
Willmering, Matthew M. [1 ,2 ]
Krishnamoorthy, Guruprasad [3 ,4 ]
Robison, Ryan K. [5 ,6 ]
Rosenberg, Jens T. [7 ]
Woods, Jason C. [1 ,2 ]
Pipe, James G. [4 ,8 ]
机构
[1] Cincinnati Childrens Hosp, Ctr Pulm Imaging Res, Div Pulm Med, Cincinnati, OH 45229 USA
[2] Univ Cincinnati Sch Med, Dept Pediat, Dept Pediat, Cincinnati, OH USA
[3] Philips Healthcare, Rochester, MN USA
[4] Univ Wisconsin Madison, Dept Radiol, Madison, WI USA
[5] Philips Healthcare, Nashville, TN USA
[6] Vanderbilt Univ, Med Ctr, Vanderbilt Univ Inst Imaging Sci, Nashville, TN USA
[7] Univ Florida, McKnight Brain Inst, Adv Magnet Resonance Imaging & Spect Facil, Gainesville, FL USA
[8] Mayo Clin, Dept Radiol, Rochester, MN USA
关键词
clinical; GTF; MSK; pulmonary; spiral; UTE; COMPRESSION; DESIGN;
D O I
10.1002/mrm.30277
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a robust 3D ultrashort-TE (UTE) protocol that can reproducibly provide high-quality images, assessed by the ability to yield clinically diagnostic images, and is suitable for clinical translation. Theory and Methods: Building on previous work, a UTE sampled with Fermat looped orthogonally encoded trajectories (FLORET) was chosen as a starting point due to its shorter, clinically reasonable scan times. Modifications to previous FLORET implementations included gradient waveform frequency limitations, a new trajectory ordering scheme, a balanced SSFP implementation, fast gradient spoiling, and full inline reconstruction. FLORET images were collected in phantoms and humans on multiple scanners and sites to demonstrate these improvements. Results: The updates to FLORET provided high-quality images in phantom, musculoskeletal, and pulmonary applications. The gradient waveform modifications and new trajectory ordering scheme significantly reduced visible artifacts. Fast spoiling reduced acquisition time by 20%-28%. Across the various scanners and sites, the inline image quality was consistent and of diagnostic quality. Total image acquisition plus reconstruction time was less than 4 min for musculoskeletal and pulmonary applications with reconstructions taking less than 1 min. Conclusion: Recently developed improvements for the FLORET sequence have enabled robust, high-quality UTE acquisitions with short acquisition and reconstruction times. This enables clinical UTE imaging as demonstrated by the implementation of the sequence and acquisition on five MRI scanners, at three different sites, without the need for any additional system characterization or measurements.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Implementation of the FLORET UTE sequence for lung imaging
    Willmering, Matthew M.
    Robison, Ryan K.
    Wang, Hui
    Pipe, James G.
    Woods, Jason C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (03) : 1091 - 1100
  • [2] Development and Clinical Translation of a Cone-Beam CT Scanner for High-Quality Imaging of Intracranial Hemorrhage
    Sisniega, A.
    Xu, J.
    Dang, H.
    Zbijewski, W.
    Stayman, J. W.
    Mow, M.
    Koliatsos, V. E.
    Aygun, N.
    Wang, X.
    Foos, D. H.
    Siewerdsen, J. H.
    [J]. MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [3] High-quality Speech Translation in the Flight Domain
    Wang, Chao
    Seneff, Stephanie
    [J]. INTERSPEECH 2006 AND 9TH INTERNATIONAL CONFERENCE ON SPOKEN LANGUAGE PROCESSING, VOLS 1-5, 2006, : 761 - +
  • [4] Human Interaction For High-Quality Machine Translation
    Casacuberta, Francisco
    Civera, Jorge
    Cubel, Elsa
    Lagarda, Antonio L.
    Lapalme, Guy
    Macklovitch, Elliott
    Vidal, Enrique
    [J]. COMMUNICATIONS OF THE ACM, 2009, 52 (10) : 135 - 138
  • [5] Digital watermarking for high-quality imaging
    Yeung, MM
    Mintzer, FC
    Braudaway, GW
    Rao, AR
    [J]. 1997 IEEE FIRST WORKSHOP ON MULTIMEDIA SIGNAL PROCESSING, 1997, : 357 - 362
  • [6] High-quality compressive ghost imaging
    Huang, Heyan
    Zhou, Cheng
    Tian, Tian
    Liu, Dongqi
    Song, Lijun
    [J]. OPTICS COMMUNICATIONS, 2018, 412 : 60 - 65
  • [7] HIGH-QUALITY IMAGING - A MARKET REVIEW
    MACKAY, C
    [J]. PHOTONICS SPECTRA, 1992, 26 (01) : 90 - &
  • [8] Promoting High-quality Breast Imaging
    Crystal, Pavel
    Munk, Peter L.
    [J]. CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2011, 62 (01): : 6 - 7
  • [9] Efficient and High-Quality Neural Machine Translation with OpenNMT
    Klein, Guillaume
    Zhang, Dakun
    Chouteau, Clement
    Crego, Josep
    Senellart, Jean
    [J]. NEURAL GENERATION AND TRANSLATION, 2020, : 211 - 217
  • [10] A High-Quality Multilingual Dataset for Structured Documentation Translation
    Hashimoto, Kazuma
    Buschiazzo, Raffaella
    Bradbury, James
    Marshall, Teresa
    Socher, Richard
    Xiong, Caiming
    [J]. FOURTH CONFERENCE ON MACHINE TRANSLATION (WMT 2019), VOL 1: RESEARCH PAPERS, 2019, : 116 - 127