The Influence of Cement Thickness within the Cap on Stress Distribution for Dental Implants

被引:1
|
作者
Ceddia, Mario [1 ]
Romasco, Tea [2 ,3 ]
Comuzzi, Luca [4 ]
Cipollina, Alessandro [5 ]
Piattelli, Adriano [4 ,5 ]
Dipalma, Gianna [6 ]
Inchingolo, Angelo Michele [6 ]
Inchingolo, Francesco [6 ]
Di Pietro, Natalia [2 ,3 ]
Trentadue, Bartolomeo [1 ]
机构
[1] Polytech Univ Bari, Dept Mech Math & Management DMMM, I-70125 Bari, Italy
[2] Univ G Annunzio Chieti Pescara, Dept Med Oral & Biotechnol Sci, Via Vestini 31, I-66100 Chieti, Italy
[3] G Annunzio Univ Chieti Pescara, Ctr Adv Studies & Technol CAST, Chieti, Italy
[4] St Camillus Int Univ Hlth & Med Sci, Sch Dent, Rome, Italy
[5] UCAM Univ Catol San Antonio Murcia, Fac Med, Murcia 30107, Spain
[6] Univ Bari Aldo Moro, Dept Interdisciplinary Med, I-70124 Bari, Italy
关键词
prosthetic cement; biomechanics; finite element analysis (FEA); implant stress analysis; dental materials; dental prosthesis; Morse cone; conometric connection; ADHESIVE RESIN CEMENTS; MECHANICAL-PROPERTIES; FRACTURE-RESISTANCE; CROWN DESIGN; MOLAR CROWNS; SCREW; RESTORATIONS; BONE; RECONSTRUCTIONS; PROSTHESIS;
D O I
10.3390/jfb15070199
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this finite element analysis (FEA) was to evaluate the stress distribution within the prosthetic components and bone in relation to varying cement thicknesses (from 20 to 60 mu m) utilized to attach a zirconia crown on a conometric cap. The study focused on two types of implants (Cyroth and TAC, AoN Implants, Grisignano di Zocco, Italy) featuring a Morse cone connection. Detailed three-dimensional (3D) models were developed to represent the bone structure (cortical and trabecular) and the prosthetic components, including the crown, cement, cap, abutment, and the implant. Both implants were placed 1.5 mm subcrestally and subjected to a 200 N load at a 45 degrees inclination on the crown. The results indicated that an increase in cement thickness led to a reduction in von Mises stress on the cortical bone for both Cyroth and TAC implants, while the decrease in stress on the trabecular bone (apical zone) was relatively less pronounced. However, the TAC implant exhibited a higher stress field in the apical area compared to the Cyroth implant. In summary, this study investigated the influence of cement thickness on stress transmission across prosthetic components and peri-implant tissues through FEA analysis, emphasizing that the 60 mu m cement layer demonstrated higher stress values approaching the material strength limit.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Effect of 3D Printing Material and Thickness on Stress Distribution of Dental Implant
    Chen, Weican
    Jiang, Si
    Shi, Shuo
    Li, Ye
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2021, 128 : 50 - 50
  • [32] Influence of Metal and Ceramic Abutments on the Stress Distribution Around Narrow Implants: A Photoelastic Stress Analysis
    Galvao, Gustavo Holtz
    Grossi, Joao Almeida
    Zielak, Joao Cesar
    Giovanini, Allan Fernando
    Furuse, Adilson Yoshio
    Gonzaga, Carla Castiglia
    IMPLANT DENTISTRY, 2016, 25 (04) : 499 - 503
  • [33] A finite element analysis of stress distribution in bone tissue surrounding uncoupled or splinted dental implants
    Bergkvist, Goran
    Simonsson, Kjell
    Rydberg, Kristofer
    Johansson, Fredrik
    Derand, Tore
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2008, 10 (01) : 40 - 46
  • [34] Analysis of stress/strain distribution in dental mini-implants manufactured by additive manufacturing and machining
    de Oliveira, Thaisa Theodoro
    Valente, Mariana Lima da Costa
    Simoes, Isadora Gazott
    Batalha, Rodolfo Lisboa
    Macedo, Ana Paula
    Bolfarini, Claudemiro
    Pauly, Simon
    dos Reis, Andrea Candido
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2023, 111 (10) : 1751 - 1762
  • [35] Three-Dimensional Finite Element Analysis of Stress Distribution in Zirconia and Titanium Dental Implants
    Villabona Lopez, Camilo Andres
    Amorin Vasco, Marco Antonio
    Ruales, Edwin
    Bedoya, Karin Apaza
    Benfatti, Cesar Magalhaes
    Luis Bezzon, Osvaldo
    Deliberador, Tatiana Miranda
    JOURNAL OF ORAL IMPLANTOLOGY, 2018, 44 (06) : 409 - 415
  • [36] Finite element analysis of stress distribution on dental implants: A study of seven clinical variables.
    Rubo, JH
    Zarb, GA
    Xiao-Yan, L
    Curran, JH
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 245 - 245
  • [37] Influence of implantoplasty on stress distribution of exposed implants at different bone insertion levels
    Mendes Tribst, Joao Paulo
    de Oliveira Dal Piva, Amanda Maria
    Shibli, Jamil Awad
    Souto Borges, Alexandre Luiz
    Tango, Rubens Nisie
    BRAZILIAN ORAL RESEARCH, 2017, 31 : 1 - 7
  • [38] Effects of varied lipid core volume and fibrous cap thickness on stress distribution in carotid arterial plaques
    Gao, Hao
    Long, Quan
    JOURNAL OF BIOMECHANICS, 2008, 41 (14) : 3053 - 3059
  • [39] Influence of occlusal forces on stress distribution in preloaded dental implant screws
    Alkan, I
    Sertgöz, A
    Ekici, E
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (04): : 319 - 325
  • [40] Endocrown restorations: Influence of dental remnant and restorative material on stress distribution
    Mendes Tribst, Joao Paulo
    de Oliveira Dal Piva, Amanda Maria
    Leite Madruga, Camila Ferreira
    Valera, Marcia Carneiro
    Souto Borges, Alexandre Luiz
    Bresciani, Eduardo
    de Melo, Renata Marques
    DENTAL MATERIALS, 2018, 34 (10) : 1466 - 1473