The Influence of Cement Thickness within the Cap on Stress Distribution for Dental Implants

被引:1
|
作者
Ceddia, Mario [1 ]
Romasco, Tea [2 ,3 ]
Comuzzi, Luca [4 ]
Cipollina, Alessandro [5 ]
Piattelli, Adriano [4 ,5 ]
Dipalma, Gianna [6 ]
Inchingolo, Angelo Michele [6 ]
Inchingolo, Francesco [6 ]
Di Pietro, Natalia [2 ,3 ]
Trentadue, Bartolomeo [1 ]
机构
[1] Polytech Univ Bari, Dept Mech Math & Management DMMM, I-70125 Bari, Italy
[2] Univ G Annunzio Chieti Pescara, Dept Med Oral & Biotechnol Sci, Via Vestini 31, I-66100 Chieti, Italy
[3] G Annunzio Univ Chieti Pescara, Ctr Adv Studies & Technol CAST, Chieti, Italy
[4] St Camillus Int Univ Hlth & Med Sci, Sch Dent, Rome, Italy
[5] UCAM Univ Catol San Antonio Murcia, Fac Med, Murcia 30107, Spain
[6] Univ Bari Aldo Moro, Dept Interdisciplinary Med, I-70124 Bari, Italy
关键词
prosthetic cement; biomechanics; finite element analysis (FEA); implant stress analysis; dental materials; dental prosthesis; Morse cone; conometric connection; ADHESIVE RESIN CEMENTS; MECHANICAL-PROPERTIES; FRACTURE-RESISTANCE; CROWN DESIGN; MOLAR CROWNS; SCREW; RESTORATIONS; BONE; RECONSTRUCTIONS; PROSTHESIS;
D O I
10.3390/jfb15070199
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this finite element analysis (FEA) was to evaluate the stress distribution within the prosthetic components and bone in relation to varying cement thicknesses (from 20 to 60 mu m) utilized to attach a zirconia crown on a conometric cap. The study focused on two types of implants (Cyroth and TAC, AoN Implants, Grisignano di Zocco, Italy) featuring a Morse cone connection. Detailed three-dimensional (3D) models were developed to represent the bone structure (cortical and trabecular) and the prosthetic components, including the crown, cement, cap, abutment, and the implant. Both implants were placed 1.5 mm subcrestally and subjected to a 200 N load at a 45 degrees inclination on the crown. The results indicated that an increase in cement thickness led to a reduction in von Mises stress on the cortical bone for both Cyroth and TAC implants, while the decrease in stress on the trabecular bone (apical zone) was relatively less pronounced. However, the TAC implant exhibited a higher stress field in the apical area compared to the Cyroth implant. In summary, this study investigated the influence of cement thickness on stress transmission across prosthetic components and peri-implant tissues through FEA analysis, emphasizing that the 60 mu m cement layer demonstrated higher stress values approaching the material strength limit.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] A device for measuring bone thickness in relation to dental implants
    Jisander, S
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (10) : 1254 - 1255
  • [22] THE INFLUENCE OF IMPLANT ELASTIC-MODULUS ON THE STRESS-DISTRIBUTION AROUND LTI CARBON AND ALUMINUM-OXIDE DENTAL IMPLANTS
    COOK, SD
    KLAWITTER, JJ
    WEINSTEIN, AM
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1981, 15 (06): : 879 - 887
  • [23] EFFECT OF ELASTIC-MODULUS AND TRABECULAR STRUCTURE ON STRESS DISTRIBUTION AROUND DENTAL IMPLANTS
    KLAWITTER, JJ
    COOK, SD
    WEINSTEIN, AM
    DAS, S
    JOURNAL OF DENTAL RESEARCH, 1979, 58 : 410 - 410
  • [24] Influence of resin cement thickness and temperature variation on mechanical behavior of dental ceramic fragment restoration
    Martini, Ana Paula
    de Souza, Fernando Isquierdo
    Anchieta, Rodolfo Bruniera
    de Almeida, Erika Oliveira
    Freitas Junior, Amilcar Chagas
    Rocha, Eduardo Passos
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (04) : 409 - 417
  • [25] CERAMIC CEMENT AS A STABILIZER FOR DENTAL IMPLANTS - AN EXPERIMENTAL-STUDY
    STRATING, H
    JONCK, LM
    GROBBELAAR, C
    JOURNAL OF DENTAL RESEARCH, 1986, 65 (04) : 627 - 627
  • [26] Finite element stress analysis of the influence of staggered versus straight placement of dental implants
    Akça, K
    Iplikçioglu, H
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2001, 16 (05) : 722 - 730
  • [27] Influence of Bone-Level Dental Implants Placement and of Cortical Thickness on Osseointegration: In Silico and In Vivo Analyses
    Gil, Javier
    Sandino, Clara
    Cerrolaza, Miguel
    Perez, Roman
    Herrero-Climent, Mariano
    Rios-Carrasco, Blanca
    Vicente Rios-Santos, Jose
    Brizuela, Aritza
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (04)
  • [28] The influence of confining stress and chemical alteration on conductive pathways within wellbore cement
    Huerta, Nicolas J.
    Bryant, Steven L.
    Strazisar, Brian R.
    Kutchko, Barbara G.
    Conrad, Lauren C.
    GREENHOUSE GAS CONTROL TECHNOLOGIES 9, 2009, 1 (01): : 3571 - 3578
  • [29] STRESS ANALYSIS OF POROUS ROOTED DENTAL IMPLANTS
    WEINSTEIN, AM
    KLAWITTER, JJ
    ANAND, SC
    SCHUESSLER, R
    JOURNAL OF DENTAL RESEARCH, 1976, 55 (05) : 772 - 777
  • [30] STRESS-ABSORBING ELEMENTS IN DENTAL IMPLANTS
    VANROSSEN, IP
    BRAAK, LH
    DEPUTTER, C
    DEGROOT, K
    JOURNAL OF PROSTHETIC DENTISTRY, 1990, 64 (02): : 198 - 205