Absolute quantitation of human serum cystatin C: candidate reference method by 15N-labeled recombinant protein isotope dilution UPLC-MS/MS

被引:0
|
作者
Zhang, Qiaoxuan [1 ,2 ]
Zhan, Min [1 ]
Peng, Xiongqiang [3 ]
Jin, Xing [4 ]
Yan, Jun [1 ]
Zhang, Pengwei [1 ]
Zhuang, Junhua [1 ]
Han, Liqiao [1 ]
Huang, Xianzhang [1 ]
机构
[1] Guangzhou Univ Chinese Med, Affiliated Hosp 2, Guangdong Prov Hosp Chinese Med, Dept Lab Med, 111,Dade Rd, Guangzhou 510120, Guangdong, Peoples R China
[2] Guangzhou Univ Chinese Med, Affiliated Hosp 2, State Key Lab Dampness Syndrome Chinese Med, Guangzhou, Peoples R China
[3] Guangzhou Univ Chinese Med, Clin Med Coll 2, Guangzhou, Peoples R China
[4] Yangzhou Univ, Affiliated Hosp, Yangzhou, Peoples R China
关键词
reference measurement procedure; cystatin C; LC-MS/MS; standardization; N-15-labeled intact protein; ENHANCED NEPHELOMETRIC IMMUNOASSAY; MASS-SPECTROMETRY; QUANTIFICATION; VALIDATION; EXPRESSION; STANDARDS;
D O I
10.1515/cclm-2024-0300
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Serum cystatin C (CysC) is a reliable and ideal endogenous marker for accurately assessing early changes in glomerular filtration rate (GFR), surpassing the limitations of creatinine-based estimated GFR. To improve the precision of GFR calculation, the development of strategies for accurately measuring serum CysC is crucial. Methods: In this study, the full-length CysC pure product and fully recombinant 15N-labeled CysC internal standard were subjected to protein cleavage. Subsequently, an LC-MS/MS method was developed for the absolute quantification of serum CysC. The traceability of the method was assigned calibrator using the amino acid reference measurement procedure (RMP). It involved calibrating the instrument using an amino acid reference material with known amino acid concentrations for calibration and comparison purposes. Results: The total imprecision of the method was determined to be <= 8.2 %, and a lower functional limit of quantification (LLoQ) was achieved. The recoveries ranged from 97.36 to 103.26 %. The relative bias between this candidate RMP for measurement of ERM-DA471-IFCC and the target value was 1.74 %. The linearity response was observed within the concentration range of 0.21-10.13 mg/L, with a high R2 value of 0.999. The results obtained using our method was consistent with those obtained using other certified RMPs. Conclusions: With the establishment of this highly selective and accurate serum CysC measurement method, it is now possible to assess the correlation between immunoassay results of serum CysC and the intended target when discrepancies are suspected in the clinical setting.
引用
收藏
页数:11
相关论文
共 32 条
  • [1] A UPLC-MS/MS method for the quantitation of Ulipristal acetate in human serum
    Nandakumar, Renu
    Praditpan, Piyapa
    Westhoff, Carolyn L.
    Cremers, Serge
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1059 : 43 - 48
  • [2] A sensitive and robust UPLC-MS/MS method for quantitation of estrogens and progestogens in human serum
    Zhang, Junmei
    Tang, Chenxiao
    Oberly, Patrick J.
    Minnigh, Margaret B.
    Achilles, Sharon L.
    Poloyac, Samuel M.
    CONTRACEPTION, 2019, 99 (04) : 244 - 250
  • [3] Isotope-dilution-LC-MS/MS candidate reference measurement procedure for cefepime in human serum
    Schaeffler, Judith
    Vogeser, Michael
    Habler, Katharina
    JOURNAL OF MASS SPECTROMETRY AND ADVANCES IN THE CLINICAL LAB, 2024, 33 : 43 - 48
  • [4] Development of a stable isotope dilution UPLC-MS/MS method for quantification of dexmedetomidine in a small amount of human plasma
    Inoue, Koichi
    Sakamoto, Tasuku
    Fujita, Yoshihito
    Yoshizawa, Saya
    Tomita, Maiko
    Min, Jun Zhe
    Todoroki, Kenichiro
    Sobue, Kazuya
    Toyo'oka, Toshimasa
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (07) : 853 - 858
  • [5] A protein standard addition method for absolute quantification of cystatin C in human serum by LC-MS/MS
    Sun, Hewei
    Li, Qing
    Lu, Yide
    Jin, Zhonggan
    Ju, Yi
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (11) : E426 - E427
  • [6] An isotope dilution LC-MS/MS-based candidate reference method for the quantification of androstenedione in human serum and plasma
    Gradl, Katrin
    Taibon, Judith
    Singh, Neeraj
    Albrecht, Eva
    Geistanger, Andrea
    Pongratz, Stephan
    Hutzler, Stefan
    Mayer, Magdalena
    Kleinschmidt, Christine
    Geletneky, Christian
    Hofmann, Verena
    Koeppl, Daniel
    Rauh, Manfred
    Kobold, Uwe
    CLINICAL MASS SPECTROMETRY, 2020, 16 : 1 - 10
  • [7] A MS data search method for improved 15N-labeled protein identification
    Zhang, Yaoyang
    Webhofer, Christian
    Reckow, Stefan
    Filiou, Michaela D.
    Maccarrone, Giuseppina
    Turck, Christoph W.
    PROTEOMICS, 2009, 9 (17) : 4265 - 4270
  • [8] Quantitative determination of Nε-(carboxymethyl)lysine in sterilized milk by isotope dilution UPLC-MS/MS method without derivatization and ion pair reagents
    Chen, Qin
    Li, Ying
    Dong, Lezhen
    Shi, Ranran
    Wu, Zhen
    Liu, Lianliang
    Zhang, Jingshun
    Wu, Zufang
    Pan, Daodong
    FOOD CHEMISTRY, 2022, 385
  • [9] An isotope-dilution UPLC-MS/MS technique for the human biomonitoring of the internal exposure to glycidol via a valine adduct at the N-terminus of hemoglobin
    Hielscher, Jan
    Monien, Bernhard H.
    Abraham, Klaus
    Jessel, Soenke
    Seidel, Albrecht
    Lampen, Alfonso
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1059 : 7 - 13
  • [10] An isotope dilution LC-MS/MS based candidate reference method for the quantification of cyclosporine A, tacrolimus, sirolimus and everolimus in human whole blood
    Taibon, Judith
    van Rooij, Milou
    Schmid, Rupert
    Singh, Neeraj
    Albrecht, Eva
    Wright, Jo Anne
    Geletneky, Christian
    Schuster, Carina
    Moerlein, Sophie
    Vogeser, Michael
    Seger, Christoph
    Pongratz, Stephan
    Kobold, Uwe
    CLINICAL BIOCHEMISTRY, 2020, 82 : 73 - 84